Laserfiche WebLink
âBank of America <br />LU-1 <br />GENERAL NOTES <br />GENERAL NOTES: <br />1. EXISTING CONDITIONS SHOWN ON THE DRAWINGS ARE BASED ON A LIMITED <br />AMOUNT OF INFORMATION AVAILABLE TO THE ENGINEER. ALL SUCH <br />CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO SUBMITTING <br />THE BID AND ADJUSTED IF NECESSARY. NO ADDITIONAL COMPENSATION SHALL <br />BE GRANTED AFTER AWARDING A BID FOR ANY EQUIPMENT, MATERIAL OR <br />LABOR REQUIRED TO REWORK OR OTHERWISE MODIFY EXISTING CONDITIONS. <br />2. THIS LIGHTING DESIGN IS BASED ON A COMBINATION OF STATE STANDARDS, <br />THE BANK'S CURRENT SECURITY POLICY FOR EXTERIOR ATM AND AFTER-HOUR <br />DEPOSITORIES AND BANK GUIDELINES FOR NON-SECURITY COMPLIANCE ZONES. <br />3. TRIM ALL TREES/LANDSCAPING TO MINIMIZE IMPEDING LIGHT FROM ANY LIGHT <br />FIXTURES THAT IMPACT THE 60' RADIUS AROUND ALL ATMS AND A RADIUS OF <br />50' AROUND ALL AFTER-HOUR DEPOSITORIES. CONSIDERATION MUST BE GIVEN <br />TO TREES/LANDSCAPING IN A STATE OF FULL FOLIAGE/BLOOM AND FUTURE <br />GROWTH. ALL LANDSCAPING WORK WILL BE PERFORMED BY OTHERS WITH A <br />SEPARATE PERMIT (IF REQUIRED). <br />4. ALL MOUNTING HEIGHTS ARE INTENDED TO THE BOTTOM OF THE FIXTURE. <br />5. CONTRACTOR TO FIELD VERIFY FIXTURE PLACEMENT DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />6. DIMENSIONING PROVIDED IS FOR PROPOSED FIXTURE LOCATIONS ONLY, UNLESS <br />OTHERWISE NOTED ON THE DRAWING. <br />7. THE CONTRACTOR SHALL ATTEMPT TO ELIMINATE THE USE OF EXPOSED <br />CONDUIT WHERE POSSIBLE. IF EXPOSED CONDUIT IS NECESSARY, THE <br />CONTRACTOR SHALL VERIFY USE WITH PROJECT MANAGER. <br />8. ALL EXISTING LIGHTS WILL BE REPLACED WITH LED LIGHTS AND ALL PROPOSED <br />LIGHTS WILL ALSO BE LED, UNLESS OTHERWISE NOTED. <br />9. ALL FIXTURES ARE TO BE MOUNTED ABOVE FINISH GRADE. <br />10. UNLESS OTHERWISE NOTED, MATCH EXISTING POLE BASES. <br />FIXTURE CLARIFICATION NOTES: <br />1. OUT OF SCOPE - EXISTING FIXTURES TO REMAIN ON SITE WITHOUT MODIFICATION. <br />NO ACTION REQUIRED UNLESS NOTED OTHERWISE. <br />2. REMOVE AND PATCH - EXISTING FIXTURES TO BE FULLY REMOVED AND ANY PAINTING, <br />PATCHING OR ELECTRICAL WORK NEEDED IS TO BE ASSESSED AND PERFORMED BY <br />CONTRACTOR. <br />3. REPLACE EXISTING FIXTURE - EXISTING FIXTURE TO BE FULLY REMOVED AND REPLACED <br />IN THE SAME LOCATION WITH A NEW FIXTURE. CONTRACTOR TO VERIFY IF POLE <br />AND/OR POLE BASE IS SUFFICIENT FOR THE NEW FIXTURES. ANY PAINTING, PATCHING <br />OR ELECTRICAL WORK NEEDED IS TO BE ASSESSED AND PERFORMED BY CONTRACTOR. <br />4. ADD NEW FIXTURE - NEW FIXTURES TO BE ADDED. ANY PAINTING, PATCHING OR <br />ELECTRICAL WORK NEEDED TO BE ASSESSED AND PERFORMED BY CONTRACTOR. <br />5. ADD NEW POLE & FIXTURE - A NEW POLE AND FIXTURE TO BE ADDED. CONTRACTOR <br />TO SPECIFY POLE TO MATCH EXISTING STYLE AND COLOR AND, IF NOT PROVIDED, POLE <br />BASE DATA FOR NEW POLE LOCATIONS. CONTRACTOR TO VERIFY IF POLE AND POLE <br />BASE IS SUFFICIENT FOR THE HEIGHT, LOCATION AND FIXTURE SPECIFIED. <br />6. GMR DOES NOT SPECIFY MOUNTING HARDWARE FOR ANY SPECIFIED FIXTURES. <br />CONTRACTOR IS TO WORK WITH DISTRIBUTOR AND/OR MANUFACTURER ON A CASE <br />BY CASE BASIS TO IDENTIFY AND ORDER REQUIRED MOUNTING HARDWARE. <br />7. CONTRACTOR TO VERIFY WHETHER EXISTING WIRING LOCATIONS OR THE ADDITION <br />OF WIRING FOR NEW FIXTURE LOCATIONS IS SUFFICIENT FOR THE DESIGNATED <br />FIXTURE LOCATION. <br />8. CONTRACTOR TO SPECIFY POLE COLOR AND TYPE PRIOR TO ORDERING. <br />9. ALL FIXTURES ARE ASSUMED BRONZE IN COLOR UNLESS NOTED OTHERWISE IN THE <br />LUMINAIRE SCHEDULE. CONTRACTOR TO CONFIRM PRIOR TO ORDERING. <br />CONTROLS & ADDITIONAL NOTES: <br />LIGHTING CONTROL NOTES: <br />THE CONTRACTOR SHALL VERIFY THE CONTROLS FOR ALL EXTERIOR LIGHTING AND ATM/AHD <br />INTERIOR LOBBIES ON THE SITE (EXCLUDING SIGNAGE) AND ADJUST ACCORDING TO THE <br />FOLLOWING: <br />· IC3 CONTROL <br />CONTRACTOR SHALL VERIFY THAT EXTERIOR LIGHTING CIRCUITS ARE CONTROLLED BY THE <br />CORRECT IC3 CIRCUIT. WHERE EXTERIOR LIGHTING IS INCLUDED ON CONTROL CIRCUITS FOR <br />INTERIOR SYSTEMS, INTERIOR LIGHTING, OR EXTERIOR SIGNAGE, CONTRACTOR SHALL <br />ADJUST EXTERIOR LIGHTING TO THE CORRECT CONTROL CIRCUIT AS REQUIRED. <br />· PHOTOCELL CONTROL: <br />CONTRACTOR SHALL REPLACE EXISTING PHOTOCELLS WITH NEW AND INSTALL IN A <br />LOCATION BEST SUITED TO PROVIDE APPROPRIATE LIGHT EXPOSURE SUCH THAT EXTERIOR <br />LIGHTS ARE ON DURING DARKNESS. <br />· TIME CLOCK CONTROL: <br />CONTRACTOR SHALL VERIFY LOCATION OF TIME CLOCK. IF TIME CLOCK IS IN ELECTRICAL <br />ROOM ALONG WITH IC3 CONTROLS, CONTRACTOR SHALL ADJUST CIRCUIT TO BE <br />CONTROLLED BY IC3 EXTERIOR LIGHTING CONTROLS. IF TIME CLOCK IS IN A REMOTE <br />LOCATION NOT IN CLOSE PROXIMITY TO THE IC3 CONTROLS, CONTRACTOR SHALL VERIFY <br />TIME CLOCK IS SET PROPERLY AND LEAVE CIRCUIT ON TIME CLOCK CONTROL. <br />· MANUAL CONTROL: <br />CONTRACTOR SHALL VERIFY THAT NO EXTERIOR LIGHTING IS CONTROLLED MANUALLY. IF <br />ANY EXTERIOR LIGHTING IS ON A MANUALLY CONTROLLED CIRCUIT, CONTRACTOR SHALL <br />ADJUST TO BE CONTROLLED BY PHOTOCELL OR IC3, WHICHEVER IS MOST ECONOMICALLY <br />ACCOMPLISHED. <br />ADDITIONAL CONTRACTOR NOTES: <br />CONSTRUCTION COMPLETION VERIFICATION <br />UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL PROVIDE VERIFICATION IN <br />WRITING TO THE BANK OF AMERICA PJM THAT ALL WORK IS COMPLETE ACCORDING TO THE <br />CONSTRUCTION DOCUMENTS, AND THAT ALL EXTERIOR LIGHTING IS FUNCTIONING DURING <br />NIGHTTIME HOURS. COMPLETION PHOTOS, TAKEN AT NIGHT, SHALL BE PROVIDED IN THE <br />FOLLOWING FORMAT: <br />PROVIDE A SINGLE DOCUMENT CONTAINING THE FOLLOWING: <br />· SITE PHOTOS FROM ALL SIDES OF BUILDING <br />· MINIMUM OF 3 PHOTOS OF EACH COMPLIANCE AREA (ATM(S), AFTER-HOUR DEPOSITORIES, <br />ASSOCIATE ENTRY) FROM DIFFERENT ANGLES <br />· MINIMUM OF 2 PHOTOS OF ALL NON-COMPLIANCE AREAS FROM DIFFERENT ANGLES <br />DESCRIPTIONREVISION <br />NO. <br />1 <br />2 <br />3 <br />REVISED <br />BY <br />CITY COMMENTS 08/31/2020 KRM <br />DESIGN BY: <br />REVIEWED BY: <br />DRAWN BY: <br />APPROVED BY: <br />KRM <br />AWDCLS <br />MLP <br />South Coast Center <br />CA6-204 <br />3730 S Bristol St <br />Santa Ana, CA <br />CONTRACTOR RESPONSIBILITY NOTES: <br />1. CONTRACTOR SHALL BE RESPONSIBLE FOR PERMITTING, INCLUDING COORDINATION <br />WITH THE LOCAL JURISDICTION AND ANY ASSOCIATED PERMIT FEES OR PROCESSING. <br />CONTRACTOR SHALL NOTIFY GMR UPON RECEIPT OF PERMIT. <br />2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING DOCUMENTS THAT ARE NOT <br />INCLUDED IN THE LIGHTING DESIGN PACKAGE. THESE INCLUDE, BUT ARE NOT LIMITED <br />TO, STAMPED ELECTRICAL DRAWINGS, STAMPED POLE BASE DRAWINGS, AND <br />PROFESSIONAL SURVEYS. <br />3. SHOULD STAMPED PHOTOMETRIC DRAWINGS BE REQUIRED, CONTRACTOR SHALL <br />ENGAGE LOCAL ENGINEER OR LIGHTING DESIGNER AS REQUIRED TO PROVIDE STAMP <br />ON GMR PHOTOMETRIC DESIGN DOCUMENTS. <br />4. CONTRACTOR SHALL PROVIDE THE BANKING CENTER NOTIFICATION AT LEAST ONE <br />WEEK IN ADVANCE OF VISITING SITES OR STARTING WORK. <br />5. CONTRACTOR SHALL VERIFY VOLTAGE REQUIREMENTS FOR FIXTURES PRIOR TO <br />PLACEMENT OF FIXTURE ORDERS. <br />6. CONTRACTOR TO VERIFY LIGHTING CONTROLS PRIOR TO BEGINNING CONSTRUCTION. <br />SEE LIGHTING CONTROL NOTES. <br />7. CONTRACTOR SHALL RECEIVE FORMAL APPROVAL FROM GMR ON ANY FIXTURE <br />MODIFICATIONS OR VARIATIONS FROM THE LUMINAIRE SCHEDULE. <br />8. CONTRACTOR SHALL VERIFY EXISTING AND PROPOSED FIXTURE MOUNTING <br />CONDITIONS IN FIELD. ANY SPECIAL MOUNTING HARDWARE NEEDED FOR PROPOSED <br />FIXTURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. <br />9. CONTRACTOR SHALL SUPPLY ALL NEW LIGHT POLES. NEW LIGHT POLES SHALL MATCH <br />EXISTING CONDITIONS ON SITE FOR POLE TYPE AND PAINT COLOR. <br />10. CONTRACTOR SHALL ORDER ALL FIXTURES FROM BORDER STATES IN ACCORDANCE <br />WITH BANK OF AMERICA NATIONAL ACCOUNT. CONTACT NATIONAL ACCOUNT QUOTES <br />DEPARTMENT AT BOA@BORDERSTATES.COM OR 704-372-3040. <br />11. CONTRACTOR SHALL PERFORM ALL NECESSARY PATCHING OR REPAINTING FOR ADDED, <br />REMOVED, OR REPLACED FIXTURES. <br />12. CONTRACTOR SHALL REPAIR ANY DISTURBED AREAS BACK TO EXISTING CONDITION <br />INCLUDING PAVED AREAS, LANDSCAPED AREAS, ETC. <br />13. CONTRACTOR SHALL VERIFY AND DOCUMENT COMPLETED WORK DURING NIGHT <br />HOURS. ALL FIXTURES MUST BE FUNCTIONAL DURING NIGHT HOURS PRIOR TO <br />SCHEDULING A FINAL SURVEY WITH GMR. <br />14. CONTRACTOR SHALL PROVIDE BEFORE AND AFTER NIGHT TIME PHOTOS OF THE SITE. <br />15. CONTRACTOR SHALL UTILIZE THE “BOA ELP INCENTIVE SITE SURVEY FORM” TO <br />DOCUMENT THE EXACT DETAILS OF EACH FIXTURE BEING REMOVED FOR REBATE AND <br />ENERGY SAVINGS CALCULATION PURPOSES. <br />16. CONTRACTOR SHALL RECEIVE A PUNCHLIST FROM GMR UPON FINAL SURVEY FOR ANY <br />REMAINING ITEMS TO BE COMPLETED. <br />NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM <br />LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH <br />ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED <br />METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES <br />MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN <br />LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. <br />v3 200827 <br />SITE ABBREVIATIONS: <br />= PROPERTY LINE <br />= ABOVE FINISHED GRADE <br />= FOOTCANDLE <br />= CONTROLLED BY OTHERS <br />= AFTER HOUR DEPOSITORY <br />PL <br />AFG <br />Fc <br />CBO <br />AHD <br />2020-161485 <br />12/15/20