Laserfiche WebLink
1 of 1 <br />JOHN A. MARTIN and ASSOCIATES, INC. □ STRUCTURAL ENGINEERS <br />Client: Sheet <br />Project: Job No 16041 <br />Date 6/12/2020 <br />Engineer KK/MF <br />Base Plate Analysis <br />N = 12 in Minimum 12" Square Plate x 1" Thick <br />B = 12 in <br />tp = 1 in <br />Fy = 36 ksi <br />f = N/2 = 6.0 in <br />f'c = 2500 psi <br />fp,max = 1381 psi <br />qmax = 16575 lbs/in <br />Mr = 6822 lb-ft <br />Pr = 238 lbs <br />e = Mr/Pr = 344 in > ecrit = N/2 - Pr/2/qmax 6.0 in <br />Design of Column Base Plates with Large Moment (Design Guide 1) <br />Y = (f+N/2) - ((f+N/2)2- 2Pr(e+f)/qmax)1/2 = 0.4 in <br />Tu = qY-Pu = 6829 lbs <br />Y < m = 3.63 in <br />Bearing Interface: <br />m = (N-0.95d)/2 = 3.63 in <br />tp,req = 2.11(fpY(m-Y/2)/Fy)1/2 = 0.50 in <br />Tension Interface: <br />x = N/2-d/2-1 = 2.50 in <br />tp,req = 2.11(Tux/B/Fy)1/2 = 0.42 in <br />tp = 1 in > tp,req = 0.50 in OK <br />DCR = 0.50 <br />Anchor Bolts Minimum (4) 3/4" Dia. x 24" Anchor Bolts <br />Wind Forces on Anchors= Seismic Forces on Anchors= <br />Vu = 426 lbs ΩVu = 78 lbs <br />Mu = 6822 lb-ft ΩMu = 1052 lb-ft <br />*Wind governs anchorage analaysis. See attached Hilti Profis Report for anchorage analysis. <br />Forces per bolt = <br />d = 9.52 in <br />Tu,bolt = Mu/d = 4302 lbs φTn = 5866 lbs DCR = 0.73 <br />Vu,bolt = Vu/4 = 107 lbs φVn = 1337 lbs DCR = 0.08 <br />DCR = (Tu/Tn)5/3 + (Vu/Vn)5/3 = 0.61 ok <br />Rogers Electric <br />CBC 2019 <br />CA6-204 <br />SANTA ANA, CALIFORNIA <br /> 950 SOUTH GRAND AVENUE, 4TH FLOOR LOS ANGELES, CA 90015 213.483.6490 <br />G:\Job16000\J16041 Light Pole Foundation\Engineering\Calcs\Santa Ana - CA6-204\1 cover page.xlsm <br />p-1 <br />2020-161485 <br />12/15/20