My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3730 S Bristol St - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
3730 S Bristol St
>
3730 S Bristol St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 4:53:33 PM
Creation date
5/30/2025 8:00:56 AM
Metadata
Fields
Template:
Plan
Permit Number
101104889
Full Address
3730 S Bristol St
Document Relationships
101104889 - Permit
(Permit - Plan)
Path:
\Building\Permits\B\Bristol St\3730 S Bristol St
Text box
ID:
1
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:19 AM
Text:
http://www.energy.ca.gov/title24/2019standards
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 <br />STATE OF CALIFORNIA <br />Outdoor Lighting <br />NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 <br />Page 7 of 9 <br />CERTIFICATE OF COMPLIANCE NRCC-LTO-E <br />Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: <br />Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 <br />Total Allowance (Watts) Ornamental: 548.873 <br />¹ FOOTNOTES: Luminaires qualifying for this allowance shall be rated < 100W and shall be post-top luminaires, lanterns, pendants or chandeliers. <br />² For luminaires indicated in Table F as linear, wattage in column 06 is W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 07 <br />instead of number of luminaires. <br />M. LIGHTING ALLOWANCE: PER SPECIFIC AREA <br />Table Instructions: Please complete this table for areas using the wattage allowance per specific area type from Table 140.7-B. More than one specific area allowance may be <br />taken in a single project, if applicable. However, multiple specific area allowances may not be taken for the exact same area on the site. <br />01 <br />Area Description <br />02 <br />Specific Area Type per <br />Table 140.7-B <br />03 <br />Specific <br />Area <br />(ft2)¹ <br />Allowed <br />Density <br />(W/ft2) <br />Extra <br />Allowance <br />(Watts) <br />CALCULATED ALLOWANCE (Watts) <br />04 05 06 <br />Luminaire <br />Name or <br />Item Tag <br />Watts per <br />Luminaire² <br /># of <br />Luminaires² <br />DESIGN WATTS <br />07 08 09 <br />Design Watts <br />10 <br />Additional <br />Allowance <br />(Watts) <br />parking Lot Lighting Security for Retail Parking <br />& Pedestrian Hardscape 42,221 0.01 422.21 UU4 189 3 567 <br />Total Design Watts for this Area: 567 422.21 <br /> <br />Total Allowance (Watts) All Areas: 422.21 <br />¹ FOOTNOTES: See Table 140.7-B for the rules for calculating the specific areas (ft²) for these additional lighting allowances. <br />² For luminaires indicated in Table F as linear, wattage in column 07 is W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 08 <br />instead of number of luminaires. <br />N. EXISTING CONDITIONS POWER ALLOWANCE (alterations only) <br />This Section Does Not Apply <br />2020-161485 <br />12/15/20
The URL can be used to link to this page
Your browser does not support the video tag.