Text box
ID:
1
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: SM
ID:
2
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: SHEET NO.
ID:
3
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: SITE PLAN - LIGHTING
ID:
4
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: 08/31/2020
ID:
5
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: 1
ID:
6
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: 1
ID:
7
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: 1
ID:
8
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: 1
ID:
9
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: 1
ID:
10
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: 1
ID:
11
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: GENERAL NOTE:
ID:
12
Creator:
Import Agent
Created:
5/30/2025 4:40 PM
Modified:
5/30/2025 9:18 AM
Text:
AutoCAD SHX Text: 1. EXISTING MINIMUM BUILDING AREA EXTERIOR LIGHTING WATTAGE FOR FIXTURES EXISTING MINIMUM BUILDING AREA EXTERIOR LIGHTING WATTAGE FOR FIXTURES BEING REMOVED OR REPLACED IS 4,900W. ALL FIXTURES BEING REPLACED WILL USE NEW L.E.D. FIXTURES. NEW BUILDING AREA WATTAGE WILL BE 2,225.4W. FOR A NET REDUCTION OF 2,674.6W. 2. EXTEND 2#10,1#10G.,3/4"C TO EXISTING EXTERIOR LIGHTING CIRCUIT FROM FED EXTEND 2#10,1#10G.,3/4"C TO EXISTING EXTERIOR LIGHTING CIRCUIT FROM FED FROM EXISTING EXTERIOR LIGHTING PANEL. CONTRACTOR TO VERIFY ALL CIRCUIT LOADS ARE 70% OR BELOW OF CIRCUIT MAX CAPACITY. 3. EXISTING CIRCUITS TO BE RE-ROUTED FROM FIXTURES TO BE REMOVED AND EXISTING CIRCUITS TO BE RE-ROUTED FROM FIXTURES TO BE REMOVED AND PATCHED TO NEW FIXTURES AS REQUIRED. CONTRACTOR TO VERIFY ALL CIRCUIT LOADS ARE 70% OR BELOW OF CIRCUIT MAX CAPACITY. 4. ALL MULTI-WIRE BRANCH CIRCUITS SHALL ORIGINATE FROM THE PANELBOARD, ALL MULTI-WIRE BRANCH CIRCUITS SHALL ORIGINATE FROM THE PANELBOARD, THE GROUNDED AND UNGROUNDED CONDUCTORS SHALL BE GROUPED WITHIN THE PANELBOARD AND THEY SHALL BE PROVIDED WITH A MEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS PER ARTICLE 210.4 OF THE 2019 CEC.