Laserfiche WebLink
LARSUN SOLAR <br />CSLB: #583458 (C-46) <br />ADDRESS: 439 E HARRISON ST. UNIT E <br />CITY|ZIP: CORONA | CA | 92879 <br />PHONE: (951) 298-9007 <br />best solar <br />PREPARED BY:DATE: <br />PROJECT #: <br />SHEET NAME: <br />SHEET #: <br />PROPOSED EQUIPMENT:SCOPE OF WORK: HOMEOWNER: CONTRACTOR: <br />PV-G.01 <br />GENERAL NOTES4/28/2022 <br />HP-192 <br />THE DAI TRAN RESIDENCE <br />405 W ALPINE AVE. <br />SANTA ANA | CA | 92707 <br />APN #: 41018218 <br />ALL-AMERICAN <br />SOLAR SERVICES <br />L.L.C. <br />x AJC <br />GENERAL NOTES <br />· ALL MATERIAL(S), EQUIPMENT, INSTALLATION & WORK SHALL <br />COMPLY W/ THE FOLLOWING APPLICABLE CODE(S): <br />-2019 CBC/2017 IBC <br />-2019 CRC/2017 IRC <br />-2019 CEC/2020 NEC <br />-2019 CMC/2017 UMC <br />-2019 CPC/2017 UPC <br />-2019 CFC/2017 IFC <br />-2019 BUILDING ENERGY CODE <br />-2019 CALGREEN <br />· EXISTING PLUMBING VENT(S), SKYLIGHT(S), EXHAUST OUTLET(S) <br />& VENTILATION INTAKE AIR OPENING(S) SHALL NOT BE COVERED <br />BY THE SOLAR PHOTOVOLTAIC SYSTEM <br />· ALL EQUIPMENT SHALL BE LISTED & LABELED BY A RECOGNIZED <br />ELECTRICAL TESTING LABORATORY AND INSTALLED PER LISTING <br />REQUIREMENTS & THE MANUFACTURER'S INSTRUCTION(S) <br /> [NEC 690.4(D)] <br />· ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, <br />INCLUDING ALL ROOF MOUNTED TRANSITION BOXES & <br />SWITCHES <br />· ALL EQUIPMENT SHALL BE PROPERLY GROUNDED & BONDED IN <br />ACCORDANCE W/ NEC ARTICLE 250 <br />· ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL <br />HAVE OVER CURRENT DEVICES LOCATED SO AS TO PROVIDE <br />OVER CURRENT PROTECTION FROM ALL SOURCES [NEC 690.9(A)] <br />· ADDITIONAL EQUIPMENT OF THE PV SYSTEM SHALL BE LOCATED <br />OUTSIDE OF THE BUILDING NEAR THE MAIN ELECTRICAL <br />SERVICES [NEC 690.12(C)] <br />· THE UTILITY INTERACTIVE INVERTER(S) SHALL AUTOMATICALLY <br />DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL <br />PRODUCTION & DISTRIBUTION NETWORK UPON LOSS OF <br />VOLTAGE IN THE SYSTEM & SHALL REMAIN IN THAT STATE UNTIL <br />THE ELECTRICAL PRODUCTION & DISTRIBUTION NETWORK <br />VOLTAGE HAS BEEN RESTORED [NEC 690.61] <br />· DUE TO THE FACT THAT PV MODULES ARE ENERGIZED <br />WHENEVER EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE <br />THE ARRAY DURING INSTALLATION & SERVICE BY SHORT <br />CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY W/ <br />OPAQUE COVERING [NEC 690.18] <br />· ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED & <br />IDENTIFIED FOR USE IN DIRECT SUNLIGHT <br /> [NEC 690.31(B), 310.8(D)] <br />· THE MODULE CONDUCTORS MUST BE TYPE USE-2 OR LISTED <br />PHOTOVOLTAIC (PV) WIRE [NEC 690.31(B)] <br />· ALL CONDUCTORS SHALL BE MARKED ON EACH END FOR <br />UNIQUE IDENTIFICATION [NEC 690.4(B)] <br />· ALL GROUND CONDUCTORS SHALL BE PROPERLY COLOR <br />IDENTIFIED PER [NEC 690.6(B)] <br />· PV SYSTEM CONNECTED ON THE LOAD SIDE OF THE SERVICE <br />DISCONNECTING MEANS IF THE OTHER SOURCE(S) AT ANY <br />DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE <br />FOLLOWING [NEC 705.12]: <br />-EACH SOURCE CONNECTION SHALL BE <br /> MADE AT THE DEDICATED CIRCUIT <br /> BREAKER OR FUSIBLE DISCONNECTING MEANS <br /> [NEC 705.12(D)(1)] <br />-THE SUM OF THE AMPERE RATING OF THE <br /> OVERCURRENT DEVICES IN CIRCUITS <br /> SUPPLYING POWER TO THE BUSBAR OR <br /> CONDUCTOR SHALL NOT EXCEED 120% OF <br /> THE RATING OF BUSBAR OR CONDUCTOR <br /> [NEC 705.12(D)(2)] <br />-THE INTERCONNECTION POINT SHALL BE ON THE <br /> LINE SIDE OF ALL GROUND-FAULT PROTECTION <br /> EQUIPMENT [NEC 705.12(D)(3)] <br />-EQUIPMENT CONTAINING OVERCURRENT <br /> DEVICES IN CIRCUIT SUPPLYING POWER TO A <br /> BUSBAR OR CONDUCTOR SHALL BE MARKED TO <br /> INDICATE THE PRESENCE OF ALL SOURCES <br /> [NEC 705.12(D)(4)] <br />-CIRCUIT BREAKER, IF BACKED, SHALL BE <br /> SUITABLE FOR SUCH OPERATION <br /> [NEC 705.12(D)(5)] <br />· TO MINIMIZE OVERHEATING OF THE BUSBAR IN PANEL BOARD, <br />THE PANEL BOARD MAIN CIRCUIT BREAKER & THE PV POWER <br />SOURCE CIRCUIT BREAKER SHALL BE PHYSICALLY LOCATED AT <br />THE OPPOSITE END OF THE BUSBAR [NEC 705.12(D)(7)] <br />· ALL THE NEC REQUIRED WARNING SIGNS, MARKING, & LABELS <br />SHALL BE POSTED ON EQUIPMENT & DISCONNECTS PRIOR TO <br />ANY INSPECTIONS TO BE PERFORMED BY THE BUILDING <br />DEPARTMENT INSPECTOR <br />· METALLIC RACEWAYS OR METALLIC ENCLOSURES ARE REQUIRED <br />WIRING METHOD FOR INSIDE A BUILDING FOR PV SYSTEM [NEC <br />690.31(E)] <br />· FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY <br />W/ TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE <br />IDENTIFIED & LISTED FOR SUCH USE [NEC 690.31(F) & 110.14(A)] <br />· CONNECTORS SHALL BE OF LATCHING OF LOCKING TYPE. <br />CONNECTORS ARE READILY ACCESSIBLE & OPERATING OVER 30 <br />VOLTS SHALL REQUIRE TOOL TO OPEN & MARK "DO NOT <br />DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT <br />INTERRUPTING" [NEC 690.33(C) & (E)(2)] <br />· EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES <br />SMALLER THAN 6AWG SHALL BE PROTECTED FROM PHYSICAL <br />DAMAGE BY A RACEWAY OR CABLE ARMOR <br /> [NEC 690.46 & 250.120(C)] <br />· FINE-STRANDED CABLES USED FOR BATTERY TERMINALS, <br />DEVICES, & CONNECTIONS REQUIRE LUGS & TERMINALS LISTED <br />& MARKED FOR THE USE [NEC 690.74(A)] <br /> (17) CANADIAN SOLAR: CS3N-395MS <br /> MODULES <br /> (17) ENPHASE: IQ7PLUS-72-2-US <br /> MICRO-INVERTERS <br />HOMEOWNER INFORMATION <br />HOMEOWNER: DAI TRAN <br />ADDRESS: 405 W ALPINE AVE. <br />CITY / STATE / ZIP: SANTA ANA | CA | 92707 <br />PHONE NUMBER: N/A <br />CONTRACTOR INFORMATION <br />CONTRACTOR: LARSUN SOLAR <br />ADDRESS: 439 E HARRISON ST. UNIT E <br />CITY / STATE / ZIP: CORONA | CA | 92879 <br />PHONE NUMBER: (951) 298-9007 <br />CSLB LICENSE: #1043108 <br />CSLB CLASS: C-46 <br />EQUIPMENT INFORMATION <br />PV MODULES: (17) CANADIAN SOLAR: CS3N-395MS <br />INVERTER(S): (17) SOLAREDGE: IQ7PLUS-72-2-US <br />MODULE AREA: 21.91 SQ. FT. <br />MODULE LENGTH: 76.40-IN. <br />MODULE WIDTH: 41.30-IN. <br />MODULE DEPTH: 1.38-IN. <br />MODULE WEIGHT: 49.60 LBS. <br />TOTAL MODULE AREA: 372.50 SQ. FT. <br />MOUNTING WEIGHT: 149.00 LBS. <br />TOTAL INSTALL WEIGHT: 992.20 LBS. <br />POINT LOAD PER MOUNT: 24.81 LBS. <br />DISTRIBUTED WEIGHT: 2.66 P.S.F. <br />ROOFING INFORMATION <br /># OF STORIES:1 <br />TYPE OF ROOF:COMP. SHINGLE <br />WIND SPEED:130 MPH <br />EXPOSURE CATEGORY: C <br />BUILDING CODE DATA <br />(E) OCCUPANCY GROUP R3 <br />(E) TYPE OF CONSTRUCTION V-B <br />(E) SPRINKLERS NO <br />APPLICABLE CODE <br />· 2019 BUILDING ST&ARDS ADMINISTRATIVE CODE <br />PART 1, TITLE 24, C.C.R. <br />[2017 IBC W/ AMENDMENTS] <br />· 2019 CALIFORNIA BUILDING CODE [CBC] <br />PART 2, TITLE 24, C.C.R. <br />[2017 IBC W/ AMENDMENTS] <br />· 2019 CALIFORNIA ELECTRICAL CODE [CEC] <br />PART 3, TITLE 24, C.C.R. <br />[2020 NEC W/ AMENDMENTS] <br />· 2019 CALIFORNIA FIRE CODE [CFC] <br />PART 9, TITLE 24 C.C.R. <br />· 2020 NATIONAL ELECTRICAL CODE NFPA 70 [NEC] <br />SHEET INDEX <br />PV-G.01 GENERAL NOTES <br />PV-S.01 SITE PLAN <br />PV-S.02 STRUCTURAL DETAILS <br />PV-E.01 ELECTRICAL DETAILS <br />PV-E.02 SINGLE LINE DIAGRAM <br />PV-S.03 WARNING SIGNAGE <br />*DATA-SHEETS ARE ATTACHED TO PACKET <br />INSTALL A NEW 6.71kW (DC)|6.08kW(AC)|6.12kW (CEC AC) PV SOLAR SYSTEM ON <br />AN (E) RESIDENTIAL ROOF. ALL WORK TO BE CONDUCTED UNDER AN ACTIVE CSLB <br />LICENSE & SHALL ADHERE TO ALL FEDERAL|STATE|LOCAL LAWS & CODES. PLEASE <br />REFERENCE ALL CODE(S) THROUGHOUT THIS PLAN SET FOR FULL COMPLIANCE. <br />405 W. Alpine Ave <br />- 2017720009/06/22