My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
405 W Alpine Ave - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Alpine Ave
>
405 W Alpine Ave
>
405 W Alpine Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:43:47 PM
Creation date
5/30/2025 8:00:59 AM
Metadata
Fields
Template:
Plan
Permit Number
20177200
101111767
Full Address
405 W Alpine Ave
Document Relationships
101111767 - Permit
(Permit - Plan)
Path:
\Building\Permits\A\Alpine Ave\405 W Alpine Ave
20177200 - Permit
(Permit - Plan)
Path:
\Building\Permits\A\Alpine Ave\405 W Alpine Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
The Enphase Q Aggregator and Enphase Q Cable <br />are part of the sixth generation Enphase IQ System. <br />These accessories provide simplicity, reliability, and <br />faster installation times. <br />. <br />Enphase Q Aggregator <br />and Q Cable Accessories <br />To learn more about Enphase offerings, visit enphase.com <br />Data Sheet <br />Enphase Q Cable Accessories <br />Enphase Q Aggregator <br /> Reduces electrical labor and eliminates wire <br />nuts for safer, faster installations <br /> Aggregates up to three fully populated 20A <br />branch circuits <br /> Supports solar arrays of up to 11.5 kW with a <br />single rooftop aggregator <br />Enphase Q Cable <br /> Two-wire, double-insulated Enphase Q Cable <br />is 50% lighter than the previous generation <br />Enphase cable <br /> New cable numbering and plug and play <br />connectors speed up installation and simplify <br />wire management <br /> Link connectors eliminate cable waste <br />Field-Wireable Connectors <br /> Easily connect Q cables on the roof without <br />complex wiring <br /> Make connections from any open connector <br />and center feed any section of cable within <br />branch limits <br /> Available in male and female connector types <br />To learn more about Enphase offerings, visit enphase.com <br />© 2017 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. <br />2017-04-05 <br />Q AGGREGATOR SPECIFICATIONS <br />Model number Q-BA-3-1P-60 <br />Dimensions 190 mm (W) x 227 mm (D) x 80 mm (H) (7.5 in (W) x 9 in (D) x 3.2 in (H)) <br />Enclosure rating NEMA3 (up to 45° from horizontal) <br />Temperature range -40° C to +55° C (-40° F to +122° F) <br />Compliance UL1703, EN62109, UL6703A <br />Q CABLE SPECIFICATIONS <br />Voltage rating 600V (connector rating 250 V) <br />Cable temperature rating 90° C (194° F) <br />'IVXMƤGEXMSR UL3003, DG cable <br />Flame test rating FT4 <br />Compliance RoHS, OIL RES I, CE, UV resistant, combined UL for Canada and United States <br />Cable insulator rating THHN/THWN-2 dry/wet <br />Q CABLE TYPES / ORDERING OPTIONS <br />Model Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box <br />Q-12-10-240 250 VAC 1.3 m (4.2 ft)Portrait 240 <br />Q-12-17-240 250 VAC 2.0 m (6.5 ft)Landscape (60-cell) 240 <br />Q-12-20-200 250 VAC 2.3 m (7.5 ft)Landscape (72-cell) 200 <br />ENPHASE Q CABLE ACCESSORIES <br />Name Model Number Description <br />Enphase Q Aggregator Q-BA-3-1P-60 Combines up to three microinverter branches into one home run. <br />Field-wireable connector (male) Q-CONN-10M Make connections from any Q Aggregator open connector <br />Field-wireable connector (female) Q-CONN-10F Make connections from any Q Cable open connector <br />Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling <br />Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount <br />Q Aggregator sealing caps (male) Q-BA-CAP-10 Sealing cap for unused aggregator connections <br />Q Cable sealing caps (female)Q-SEAL-10 One needed to cover each unused connector on the cabling <br />Terminator Q-TERM-10 Terminator cap for unused cable ends <br />Replacement DC Adaptor (MC4) Q-DCC-2 DC adaptor to MC4 (max voltage 100 VDC) <br />Replacement DC Adaptor (UTX) Q-DCC-5 DC adaptor to UTX (max voltage 100 VDC) <br />Enphase Q Cable Accessories <br />TERMINATOR <br />Terminator cap for unused cable <br />ends, sold in packs of ten <br />(Q-TERM-10) <br />SEALING CAPS <br />Sealing caps for unused <br />aggregator and cable connections <br />(Q-BA-CAP-10 and Q-SEAL-10) <br />DISCONNECT TOOL <br />Plan to use at least one per <br />installation, sold in packs of ten <br />(Q-DISC-10) <br />CABLE CLIP <br />Used to fasten cabling to the racking <br />or to secure looped cabling, sold in <br />packs of ten (Q-CLIP-100) <br />405 W. Alpine Ave <br />- 2017720009/06/22
The URL can be used to link to this page
Your browser does not support the video tag.