My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
415 E Camile St - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Camile St
>
415 E Camile St
>
415 E Camile St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 4:53:33 PM
Creation date
5/30/2025 8:00:59 AM
Metadata
Fields
Template:
Plan
Permit Number
20176788
101111218
Full Address
415 E Camile St
Document Relationships
101111218 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Camile St\415 E Camile St
20176788 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Camile St\415 E Camile St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
POWER TO THIS BUILDING ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN <br />CAUTION <br />SERVICE BY QUALIFIED PERSONNEL ONLY <br />N <br />Nathan Draeger <br />REV: DESCRIPTION: BY: DATE: <br />DRAWING TITLE: <br />DESIGNER: <br />DESIGN MGR: <br />DWG PAGE: <br />ENGINEER OF RECORD <br />Alexis Arellano <br />NE <br />W <br /> <br />P <br />V <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />: <br /> <br />7 <br />. <br />6 <br />0 <br />0 <br /> <br />D <br />C <br /> <br />/ <br /> <br />7 <br />. <br />0 <br />0 <br />0 <br /> <br />A <br />C <br />Di <br />a <br />n <br />a <br /> <br />S <br />a <br />l <br />g <br />a <br />d <br />o <br />41 <br />5 <br /> <br />E <br /> <br />C <br />a <br />m <br />i <br />l <br />e <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />AP <br />N <br />: <br /> <br />4 <br />0 <br />4 <br />0 <br />5 <br />1 <br />0 <br />8 <br />7/21/2022 <br />7/21/2022 <br />DATE: TIME: <br />08:41 pm <br />08:41 pm <br />PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL <br />RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT <br />EXPRESS WRITTEN CONSENT. <br />ROOFTOP <br />PV ARRAY <br />UTILITY METER AND <br />MAIN SERVICE PANEL <br />INVERTER <br />YOU ARE <br />HERE <br />PLACARD & <br /> PLACARD MAP <br />P6 <br />LABELING PLAN LABEL DIRECTORY <br />6"X6" DISCONNECT DIRECTORY PLAQUE <br />INSTALL AT MAIN SERVICE PANEL <br />FORMAT <br />1. WHITE LETTERING ON A RED BACKGROUND <br />2. MINIMUM 3/8 INCHES LETTER HEIGHT <br />3. ALL LETTERS SHALL BE CAPITALIZED <br />4. ARIAL OR SIMILAR FONT (NON-BOLD) <br />MATERIAL <br />REFLECTIVE, WEATHER RESISTANT MATERIAL <br />SUITABLE FOR THE ENVIRONMENT <br />(USE UL-969 AS STANDARD FOR WEATHER RATING). <br />DURABLE ADHESIVE MATERIALS <br />PROPERTY MAP PROPERTY MAP NOTES: <br />BE <br />T <br />T <br />E <br />R <br /> <br />E <br />A <br />R <br />T <br />H <br /> <br />E <br />L <br />E <br />C <br />T <br />R <br />I <br />C <br /> <br />I <br />N <br />C <br />. <br />18 <br />1 <br />5 <br /> <br />W <br />I <br />L <br />S <br />H <br />I <br />R <br />E <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />, <br /> <br />S <br />T <br />E <br />. <br /> <br />9 <br />0 <br />8 <br />/ <br />9 <br />0 <br />9 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />PH <br />O <br />N <br />E <br /> <br /># <br />: <br /> <br />( <br />8 <br />8 <br />8 <br />) <br /> <br />3 <br />7 <br />3 <br />- <br />9 <br />3 <br />7 <br />9 <br />LI <br />C <br /> <br /># <br />: <br /> <br />C <br />1 <br />0 <br />- <br />1 <br />0 <br />2 <br />4 <br />4 <br />6 <br />0 <br />STICKER LOCATED INSIDE <br />PANEL NEXT TO PV BREAKER <br />11 <br />[CEC 690.14(C)(2)] PLACE ON AC DISCONNECT <br />8 <br />9 <br />[CEC 705.12(B)(2)(3)(C)] PLACE THIS LABEL AT P.O.C. TO <br />SERVICE DISTRIBUTION EQUIPMENT <br />LABELING NOTES: <br />1.1 LABELING REQUIREMENTS BASED ON THE <br />NATIONAL ELECTRICAL CODE, <br />INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD <br />1910.145, ANSI Z535. <br />1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE <br />AUTHORITY HAVING JURISDICTION. <br />1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO <br />WITHSTAND THE ENVIRONMENT INVOLVED. <br />1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” <br />AND PERMANENTLY AFFIXED. <br />PHOTOVOLTAIC <br />SOLAR BREAKER <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />! WARNING <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRRENT DEVICES, EXCLUDING <br />MAIN SUPPLY OVERCURRENT <br />DEVICE, SHALL NOT EXCEED <br />AMPACITY OF BUSBAR <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />10 <br />FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND <br />CONDUCTORS LEAVING THE ARRAY: SIGN TO BE <br />LOCATED ON OR NO MORE THAN 3 FT AWAY FROM <br />SERVICE DISCONNECTING MEANS TO WHICH THE PV <br />SYSTEMS ARE CONNECTED AND SHALL INDICATE THE <br />LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN <br />SWITCHES IF NOT AT THE SAME LOCATION. [CEC <br />690.56(C)(1)(A)] <br />2 <br />3 <br />[CEC 690.53] AT EACH DC DISCONNECT MEANS <br />[CEC 690.5(C)] PLACE THIS LABEL ON ALL <br />DISCONNECTING MEANS WHERE <br />ENERGIZED IN AN OPEN POSITION <br />1 <br />[CEC 690.31(G)3 & 4] PLACE ON JUNCTION BOXES <br />AND CONDUIT EVERY 10' <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />! <br />MAXIMUM VOLTAGE <br />PHOTOVOLTAIC SYSTEM <br />DC DISCONNECT ! <br />MAX CIRCUIT CURRENT <br />15 AMPS <br />! <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />ELECTRIC SHOCK HAZARD <br />WARNING <br />MAX RATED OUTPUT <br />CURRENT OF THE CHARGE <br />CONTROLLER <br />OR DC-DC CONVERTER <br />4 <br />[CEC 690.12(5)] PLACE ON INVERTER <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH <br />RAPID SHUTDOWN <br />7 <br />6 <br />5 <br />[CEC 690.54] PLACE LABEL AT "INTERACTIVE POINT OF <br />INTERCONNECTION" (AT MAIN SERVICE PANEL AND <br />SUBPANEL IF APPLICABLE) <br />[CEC 690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT <br />CONTAINING OVERCURRENT DEVICES IN CIRCUITS <br />SUPPLYING POWER TO A BUSBAR OR CONDUCTORS <br />SUPPLIED FROM MULTIPLE SOURCES <br />CEC 705.12(B)(2)(3)(B) PLACE THIS LABEL AT P.O.C. TO <br />SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL <br />AND SUBPANEL IF APPLICABLE) <br />! <br />SOURCES: UTILITY GRID AND <br />PV SOLAR ELECTRIC SYSTEM <br />DUAL POWER SUPPLY <br />WARNING <br />! <br />RATED AC OUTPUT CURRENT <br />NOMINAL OPERATING AC VOLTAGE 240 V <br />PHOTOVOLTAIC SYSTEM <br />AC DISCONNECT ! <br />! <br />DO NOT RELOCATE <br />THIS OVERCURRENT <br />DEVICE <br />INVERTER OUTPUT CONNECTION <br />WARNING <br />16A <br />480 VDC <br />11 AMPS <br />SUB <br />PANEL <br />5 6 <br />JUNCTION <br />BOX <br />METER <br />MAIN SERVICE <br />PANEL <br />1 <br />7 <br />6 8 <br />10 <br />9 <br />INVERTER <br />INTEGRATED <br />DC DISCONNECT <br />4 <br />2 3 <br />1 <br />WHEN <br />APPLICABLE <br />AC <br />DISCONNECT <br />PRODUCTION <br />METER <br />AC <br />DISCONNECT <br />ROOFTOP ARRAY <br />AC LOAD <br />CENTER <br />7 <br />3 5 8 <br />3 5 8 <br />3 5 <br />5 <br />11 <br />WHEN <br />APPLICABLE <br />WHEN <br />APPLICABLE <br />WHEN <br />APPLICABLE <br />WHEN <br />APPLICABLE <br />415 E Camile St <br />07/28/22
The URL can be used to link to this page
Your browser does not support the video tag.