CONTRACTOR: <br />Lic # 974115 <br />Ara Petrosyan <br />ALBERTO BERNABE <br />4318 W McFadden Ave, <br />Santa Ana,CA 92704,USA <br />LA Solar Group <br />16238 B Raymer St., <br />Van Nuys, CA 91406 <br />Phone: (818) 373-0077 <br />LIC TYPE: C-46, C-10, C-39 <br />Project Name and Address <br />No. Revision/Issue Date <br />General Notes <br />Project <br />Date <br />Scale <br />PV SYSTEM <br />AS INDICATED <br />December 25, 2021 PV 05 <br />SYSTEM <br />LABELING DETAIL <br />Ara Panosyan <br />Designed By : <br />MAIN SERVICE <br />SYSTEM LABELING DETAIL <br />PHOTOVOLTAIC REQUIREMENTS <br />PER CALIFORNIA ELECTRICAL CODE ARTICLE 690 <br />PHOTOVOLTAIC SYSTEM DISCONNECT <br />AC OUTPUT CURRENT - 35.94 AMPS <br />OPERATING VOLTAGE 240 VOLTS <br />WARNING <br />DO NOT TOUCH TERMINALS ON BOTH <br />LINE AND LOAD SIDES MAY BE <br />ENERGIZED IN THE OPEN POSITION <br />WARNING <br /> ELECTRIC SHOCK HAZARD. <br />DO NOT TOUCH TERMINALS. <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN THE <br />OPEN POSITION. <br />Marking shall be placed on interior and <br />exterior DC conduit, raceways, enclosures <br />and cable assemblies every 10 ft (3048 <br />mm) within 1 ft (305 mm) of turns or bands <br />and within 1 ft (305 mm) above and below <br />penetrations of roof/ceiling assemblies, <br />walls or barriers. <br />COMBINER / <br />JUNCTION <br />BOX ARRAY <br />WARNING <br />DO NOT TOUCH TERMINALS <br />ON BOTH LINE AND <br />LOAD SIDES MAY BE <br />ENERGIZED IN THE OPEN <br />POSITION <br />ON <br />OFF <br />DC <br />DISCONNECT <br />(if applicable)RAPID SHUTDOWN <br />INVERTER <br />(if applicable) <br />ON <br />OFF <br />AC <br />DISCONNECT <br />WARNING <br />RATED OUTPUT CURRENT 35.94 AMPS <br />AC NORMAL OPERATING VOLTAGE 240 VOLTS <br />WARNING: <br />PHOTOVOLTAIC POWER SOURCE <br />This lable is to be located adjacent to the PV breaker36'' to 75'' above the floor or grade <br />level to center of performance meters <br />(IF APPLICABLE) <br />SERVICE <br />METER <br />METER <br />SOCKET <br />(if applicable) <br />WARNING: <br />PHOTOVOLTAIC <br />POWER SOURCE <br />WARNING <br />INVERTER OUTPUT <br />CONNECTION. DO NOT <br />RELOCATE THIS <br />OVERCURRENT DEVICE <br />OPTIONAL SOLAR P.V. ONLY <br />COMBINER PANEL BOARD <br />PV SUB PANEL <br />(if applicable) <br />WARNING <br />PHOTOVOLTAIC SYSTEM - DO NOT <br />RELOCATE THIS BREAKER <br />WARNING <br />ELECTRIC SHOCK HAZARD. <br />IF GROUND FAULT IS INDICATED <br />NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br />UNGROUNDED AND ENERGIZED. <br />Solar Source Only <br />No Other Loads in <br />This panel <br />CEC 690.13(B) <br />CEC 690.13(B) <br />PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />CEC 690.13(B) <br />WARNING <br />ELECTRIC SHOCK <br />HAZARD. THE DC CONDUCTORS <br />OF THIS PHOTOVOLTAIC <br />SYSTEM ARE UNGROUNDED <br /> AND MAY BE ENERGIZED. <br />CEC 690.41(A) <br />CEC 690.53 <br />CEC 690.14(C)(2) <br />PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />CEC 690.54 <br />WARNING <br />DUAL POWER SOURCES SECOND SOURCE IS <br />PHOTOVOLTAIC SYSTEM <br />CEC 705.12(B)(3) <br />705.12.(B)(2)(3)(b) <br />PHOTOVOLTAIC <br />SYSTEM EQUIPPED <br /> WITH RAPID <br />SHUTDOWN <br /> 690.56 <br />CEC. 5. MAKINGS, LABELS AND WIRING SIGNS. <br />A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. <br />This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for <br />smoke removal <br />B. Main Service Disconnect. <br />1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if <br />the main service disconnect is operable with the service panel closed. <br />2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where <br />the level is operated. <br />3. Markings: Verbiage, Format and Type of Material. <br />a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED <br />b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non <br />bold. <br />c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable <br />adhesive materials meet this requirement. <br />C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: <br />1. Markings: Verbiage, Format and Type of Material. <br />a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, <br />at turns, above and for below penetrations, all DC combiners and junction boxes <br />b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement. <br />c. Inverters are not required to have caution markings <br />1. Marking is required on all interior and exterior DC conduit, raceway, enclosures, cable assemblies, and junction boxes, combiner and <br />disconnects. <br />2. The materials used for marking shall be reflective, weather resistant material suitable for the environment.Minimum 3/8" letter height; <br />all upper case letters Arial or similar font; Red background with wight lettering. <br />3. Marking shall contain: WARNING: PHOTOVOLTAIC POWER SOURCE. <br />4. Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location were the disconnect is <br />operated. <br />FIRE DEPARTMENT REQUIREMENTS <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM <br />THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN : <br />CAUTION <br />North <br />WARNING PLAQUE <br />MAIN SERVICE <br />INVERTER TYPE: Micro <br />264 V <br />14.98 A <br />SERVICE POINT & <br />UTILITY METERING <br />PV SUB PANEL <br />McFadden Ave <br />4318 W McFadden <br />Ave01/14/22