My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4609 W El Don Pl - Plan
PBA
>
Building
>
ProjectDox
>
E
>
El Don Pl
>
4609 W El Don Pl
>
4609 W El Don Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 4:53:33 PM
Creation date
5/30/2025 8:00:59 AM
Metadata
Fields
Template:
Plan
Permit Number
20177153
101111434
101112251
Full Address
4609 W El Don Pl
4609 1/2 W El Don Pl
Document Relationships
101111434 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\El Don Pl\4609 W El Don Pl
101112251 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\El Don Pl\4609 1/2 W El Don Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PV MODULE <br />MICROINVERTER <br />6 IN <br />BRANCH <br />PM1-6 <br />440W <br />1 2 <br />3 4 <br />5 6 <br />7 <br />JUNCTION BOX <br />JB1 <br />1 <br />AC DISCONNECT <br />2 <br />SW1 <br />30A <br />AC COMBINER <br />COMM <br />GATEWAY <br />3 <br />CB1 <br />10A <br />C1 <br />8 9 <br />PV DISCONNECT <br />SW2 <br />30A <br />4 <br />SQUARE D <br />DU221RB <br />MAIN SERVICE PANEL <br />AC <br />GEC <br />LO <br />A <br />D <br />S <br />BIDIRECTIONAL <br />UTILITY METERKWHR <br />LOAD <br />LINE <br />KWHR <br />LOAD <br />LINE <br />HOMELINE <br />120/240V 1ΙΈ, 3W <br />225A BUSBAR (TOP-FED) <br />200A MAIN BREAKER <br />30A-RATED AUX. INPUT <br />200A <br />CB2-4 <br />10A <br />10 <br />11 <br />MODULES <br />REF. QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING <br />PM1-6 6 URECO FAM440E8G-BB 440W 411W 11.34A 10.74A 49.6V 41.0V -0.1339V/°C (-0.27%/°C)20A <br />INVERTERS <br />REF. QTY.MAKE AND MODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY <br />I1-6 6 ENPHASE IQ8PLUS-72-2-US 240V NOT SOLIDLY GROUNDED 290W 1.2A 15.0A 60V 97.0% <br />PASS-THRU BOXES AND COMBINERS <br />REF. QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE <br />JB1 1 GENERIC GEN-AWB-TB-1-4X OR EQUIV.30A 240VAC / 600VDC <br />C1 1 ENPHASE IQ COMBINER 4C OR EQUIV.64A 240VAC <br />DISCONNECTS <br />REF. QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE <br />SW1-2 2 SQUARE D DU221RB OR EQUIV.30A 240VAC <br />OCPDS <br />REF. QTY.RATED CURRENT MAX VOLTAGE <br />CB1-2 2 10A 240VAC <br />F1-2 2 10A 240VAC <br />SYSTEM SUMMARY <br />INVERTERS PER BRANCH 6 <br />MAX AC CURRENT 7.26A <br />MAX AC OUTPUT 1,740W <br />ARRAY STC POWER 2,640W <br />ARRAY PTC POWER 2,465W <br />MAX AC CURRENT 7A <br />MAX AC POWER OUTPUT 1,740W <br />DERATED AC POWER OUTPUT 1,740W <br />NOTES <br />RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER CEC 690.12(B). PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY (DEFINED AS 3 FEET FROM THE POINT OF PENETRATION INTO <br />A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY) SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION. CONDUCTORS LOCATED INSIDE OF THE ARRAY BOUNDARY <br />SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN. <br />1 <br />ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER CEC 690.12(B).2 <br />THE DC AND AC CONNECTORS OF THE ENPHASE IQ8PLUS-72-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY CEC 690.15(D). MATING CONNECTORS SHALL COMPLY WITH CEC <br />690.33. <br />3 <br />INVERTER IS COMPLIANT WITH CALIFORNIA PUBLIC UTILITIES COMMISSION RULE 21 FOR SMART INVERTERS. INSTALLER SHALL CONFIGURE INVERTER TO OPERATE IN REACTIVE POWER PRIORITY MODE.4 <br />DC PV CONDUCTORS ARE NOT SOLIDLY-GROUNDED. NO DC PV CONDUCTOR SHALL BE WHITE- OR GRAY-COLORED5 <br />ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY CEC 250.4(B) AND PART III OF ARTICLE 250 AND <br />DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO CEC 690.47(A) AND CEC 250.169 AND INSTALLED IN COMPLIANCE WITH <br />CEC 250.64. <br />6 <br />MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 52.5V AT 3°C (3.3°C - 25°C) X -0.134V/C + 49.6V = 52.5V).7 <br />AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH CEC 705.12(B)(2)(3)(C).8 <br />THE ENPHASE IQ COMBINER 4C CONTAINS A FACTORY-INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 15A.9 <br />POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT USING AUXILIARY ENERGY INPUT OF SOLAR-READY MAIN SERVICE PANEL, IN COMPLIANCE WITH CEC 705.12(A).10 <br />PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER. <br />DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH CEC 230.72. <br />11 <br />CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS <br />ID TYP CONDUCTOR CONDUIT / CABLE <br />CURRENT-CARRYING <br />CONDUCTORS IN <br />CONDUIT/CABLE. <br />OCPD EGC TEMP. CORR. <br />FACTOR FILL FACTOR CONT. <br />CURRENT <br />MAX. <br />CURRENT <br />(125%) <br />BASE AMP.DERATED <br />AMP. <br />TERM. <br />TEMP. <br />RATING <br />AMP. @ <br />TERM. <br />TEMP. <br />RATING <br />LEN. V.D. <br />1 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.76 (52°C) 1.0 7.26A 9.07A 30A 23A 75°C 25A 23.7FT 0.28% <br />2 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.96 (32°C) 1.0 7.26A 9.07A 30A 29A 75°C 25A 48IN 0.05% <br />3 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.96 (32°C) 1.0 7.26A 9.07A 30A 29A 75°C 25A 48IN 0.05% <br />4 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.96 (32°C) 1.0 7.26A 9.07A 30A 29A 75°C 25A 48IN 0.05% <br />REVISIONS <br />PROJECT ID: <br />CREATED BY: <br />CHECKED BY: <br />DATE: <br />SCALE: <br />GR <br />I <br />D <br />- <br />T <br />I <br />E <br />D <br /> <br />S <br />O <br />L <br />A <br />R <br /> <br />P <br />O <br />W <br />E <br />R <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />46 <br />0 <br />9 <br /> <br />W <br /> <br />E <br />L <br /> <br />D <br />O <br />N <br /> <br />P <br />L <br />PV-3 <br />P-525014 <br />05/13/22 <br />B.H. <br />ED8F10-3 <br />SINGLE-LINE DIAGRAM <br />NG <br />U <br />Y <br />E <br />N <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />1 <br />PV-3 <br />SINGLE-LINE DIAGRAM <br />NTS <br />GROUNDING NOTES <br />1 <br />ALL EQUIPMENT SHALL BE <br />PROPERLY GROUNDED PER THE <br />REQUIREMENTS OF NEC ARTICLES <br />250 & 690 <br />2 <br />PV MODULES SHALL BE GROUNDED <br />TO MOUNTING RAILS USING MODULE <br />LUGS OR RACKING INTEGRATED <br />GROUNDING CLAMPS AS ALLOWED <br />BY LOCAL JURISDICTION. ALL OTHER <br />EXPOSED METAL PARTS SHALL BE <br />GROUNDED USING UL-LISTED LAY-IN <br />LUGS. <br />3 <br />INSTALLER SHALL CONFIRM THAT <br />MOUNTING SYSTEM HAS BEEN <br />EVALUATED FOR COMPLIANCE WITH <br />UL 2703 "GROUNDING AND BONDING" <br />WHEN USED WITH PROPOSED PV <br />MODULE. <br />4 <br />IF THE EXISTING MAIN SERVICE <br />PANEL DOES NOT HAVE A <br />VERIFIABLE GROUNDING <br />ELECTRODE, IT IS THE <br />CONTRACTOR'S RESPONSIBILITY TO <br />INSTALL A SUPPLEMENTAL <br />GROUNDING ELECTRODE. <br />5 <br />AC SYSTEM GROUNDING <br />ELECTRODE CONDUCTOR (GEC) <br />SHALL BE A MINIMUM SIZE #8AWG <br />WHEN INSULATED, #6AWG IF BARE <br />WIRE. <br />6 <br />EQUIPMENT GROUNDING <br />CONDUCTORS SHALL BE SIZED <br />ACCORDING TO NEC ARTICLE 690.45, <br />AND BE A MINIMUM OF #10AWG <br />WHEN NOT EXPOSED TO DAMAGE, <br />AND #6AWG SHALL BE USED WHEN <br />EXPOSED TO DAMAGE <br />7 <br />GROUNDING AND BONDING <br />CONDUCTORS, IF INSULATED, SHALL <br />BE COLOR CODED GREEN, OR <br />MARKED GREEN IF #4AWG OR <br />LARGER <br />GENERAL ELECTRICAL <br />NOTES <br />1 <br />UTILITY HAS 24-HR UNRESTRICTED <br />ACCESS TO ALL PHOTOVOLTAIC <br />SYSTEM COMPONENTS LOCATED AT <br />THE SERVICE ENTRANCE. <br />2 <br />CONDUCTORS EXPOSED TO <br />SUNLIGHT SHALL BE LISTED AS <br />SUNLIGHT RESISTANT PER NEC <br />ARTICLE 300.6 (C) (1) AND ARTICLE <br />310.10 (D). <br />3 <br />CONDUCTORS EXPOSED TO WET <br />LOCATIONS SHALL BE SUITABLE FOR <br />USE IN WET LOCATIONS PER NEC <br />ARTICLE 310.10 (C). <br />4609 W El Don Pl - <br />10111143409/21/22
The URL can be used to link to this page
Your browser does not support the video tag.