Laserfiche WebLink
© 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 2 <br />RATINGS <br />Product markings are located on the Grounding Lug bolt <br />head. <br />MARKINGS <br />UL 2703 LISTeD <br />Conforms to STD UL 2703 Standard for Safety First edition: Mounting Systems, Mounting Devices, Clamping/ <br />Retention Devices, and Ground Lugs for Us e with Flat-Plat e Photovoltaic Modules and Panels <br />• Max Overcurrent Protective Device (OCPD) Rating: 40A <br />• Max Module Size: 30.5 ft² <br />• Module Orientation: Portrait or Landscape <br />• System Design Load Rating: 10 PSF downward, 5 PSF upward, 5 PSF lateral <br />• Actual system structural capacity including spans and cantilevers are defined by PE stamped certification letters. <br />• CAMO Specific Design Load rating: 50 PSF downward, 50 PSF upward, 15 PSF lateral <br />Certified to CSA TIL No. A-40 Photovoltaic Module Racking Systems <br />• Load Rating: 2400 PA [50 PSF] <br />CLASS A SYSTeM FIRe RATING PeR UL 2703 <br />• Any Roof Slope with Module Types 1, 2, 3, 13, 19, 25 & 29. <br />• Any module-to-roof gap is permitted, with no perimeter guarding required. This rating is applicable with any third-party <br />attachment. <br />• Class A rated PV systems can be installed on Class A, B, and C roofs without affecting the roof fire rating. <br />WATeR SeAL RATINGS: <br />• UL 441 (Flashfoot2, All Tile Hook, Knockout Tile, Flashvue, L-Mount) <br />• TAS 100(A)-95 (Flashfoot2, All Tile Hook, Knockout Tile, Flashvue, L-Mount, Qbase) <br />• Tested and evaluated without sealant. <br />• Any roofing manufacturer approved sealant is allowed. Ratings applicable for roof slopes between 2:12 and 12:12 <br />STRUCTURAL CeRTIFICATION <br />• Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7 <br />FLORIDA PRODUCT APPROVAL #FL29843 <br />• Conforms to TAS202, TAS100(A) <br />• Approved for installation both inside and outside High Velocity Hurricane Zones (HVHZ) <br />• Allowable design pressure up to +100/-100 PSF <br />• Additional details and full list of approved components can be found Here. <br />#5003807 <br />8431 Murphy Drive <br />Middleton, WI 53562 USA <br />Telephone: 608.836.4400 <br />Facsimile: 608.831.9279 <br />www.intertek.com <br />Test Verification of Conformity <br />This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are <br />limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense <br />or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its <br />marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results <br />referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been <br />under an Intertek certification program. <br />GFT-OP-11a (24-MAR-2014) <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />Signature: <br />Name: Nalini Mandadi <br />Position: Project Engineer <br />Date: 11/14/2014 <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of <br />the referenced specifications at the time the tests were carried out. <br />Applicant Name & Address: IronRidge, Inc. <br />28357 Industrial Blvd <br />Hayward, CA 94545 <br />USA <br />Product Description: Flush Mount System with XR Rails. <br />Ratings & Principle <br />Characteristics: <br />Fire Class Resistance Rating: <br />-Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, <br />2, 3, 13, 19, 25 and 29 listed photovoltaic modules. Class A Fire Rated for Steep Slope <br />applications with Type1, 2 and 3, listed photovoltaic modules. Tested with a 5” gap (distance <br />between the bottom the module frame and the roof covering), per the standard this system can <br />be installed at any gap allowed by the manufacturers installation instructions. No perimeter <br />guarding is required. This rating is applicable with any IronRidge or 3’rd party roof anchor. <br />Models: IronRidge Flush Mount with XR Rails <br />Brand Name:IronRidge Flush Mount <br />Relevant Standards : UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, <br />Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules <br />and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, <br />2014, (Section 31.2) Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. <br />Verification Issuing Office: Intertek Testing Services NA, Inc. <br />8431 Murphy Drive <br />Middleton, WI 53562 <br />Date of Tes ts: 08/27/2014 to 03/17/2015 <br />Test Report Number(s): 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1, <br />104428358MID-001 EEV <br />Revision Summary 8/27/2020 Added type 13, 19, 25 and 29 to system, update address. <br />This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically <br />imply product certification. <br /> <br />Completed by: Chris Zimbrich Reviewed by: Chad Naggs <br />Title: Technician I, Fire Resistance Title: Technical Team Lead, Fire Resistance <br /> <br />Signature: Signature: <br />Date: 08/27/2020 Date: 08/27/2020 <br />4609 W El Don Pl - <br />101111434 & Rev <br />10111225111/23/22