My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4609 W El Don Pl - Plan
PBA
>
Building
>
ProjectDox
>
E
>
El Don Pl
>
4609 W El Don Pl
>
4609 W El Don Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 4:53:33 PM
Creation date
5/30/2025 8:00:59 AM
Metadata
Fields
Template:
Plan
Permit Number
20177153
101111434
101112251
Full Address
4609 W El Don Pl
4609 1/2 W El Don Pl
Document Relationships
101111434 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\El Don Pl\4609 W El Don Pl
101112251 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\El Don Pl\4609 1/2 W El Don Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
GENERAL NOTES <br />1 <br />EQUIPMENT LIKELY TO BE WORKED UPON WHILE <br />ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT <br />SATISFY MINIMUM WORKING CLEARANCES PER CEC <br />110.26. <br />2 24/7 UNESCORTED KEYLESS ACCESS SHALL BE <br />PROVIDED TO ALL SOUTHERN CALIFORNIA EDISON CO <br />EQUIPMENT. <br />3 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED <br />BY A NATIONALLY RECOGNIZED TESTING LABORATORY <br />FOR THE INTENDED USE. <br />4 <br />CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL <br />EQUIPMENT, CABLES, ADDITIONAL CONDUITS, <br />RACEWAYS, AND OTHER ACCESSORIES NECESSARY <br />FOR A COMPLETE AND OPERATIONAL PV SYSTEM. <br />5 ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS <br />WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE <br />A RAINTIGHT FIT, PER CEC 358.42. <br />(N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC <br />ARRAY. 4/12 (18.4°) SLOPED ROOF, 6 PV MODULES <br />(BLACK FRAME, BLACK BACKSHEET), 340° AZIMUTH <br />(N) TRANSITION BOX (JB1), OUTDOOR, OUTPUT CIRCUIT <br />CONDUCTORS SHALL BE RUN IN EMT CONDUIT <br />THROUGH THE INTERIOR OF THE BUILDING <br />(N) DISCONNECT (SW1), OUTDOOR <br />(N) VISIBLE-OPEN TYPE, LOCKABLE, READILY <br />ACCESSIBLE, LABELED PV SYSTEM DISCONNECT <br />LOCATED WITHIN 10 FT OF UTILITY METER (SW2), <br />OUTDOOR <br />(N) AC COMBINER (C1), OUTDOOR, OUTPUT CIRCUIT <br />CONDUCTORS SHALL BE RUN IN EMT CONDUIT OVER <br />ROOF NO CLOSER THAN 7/8″ ABOVE ROOF SURFACE <br />(E) UTILITY METER, OUTDOOR <br />(E) MAIN SERVICE PANEL (MSP), OUTDOOR <br />ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH <br />THE INTERIOR OF THE BUILDING, AND WHERE <br />POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING <br />MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE <br />THE ROOF. <br />P-525014 <br />GR <br />I <br />D <br />- <br />T <br />I <br />E <br />D <br /> <br />S <br />O <br />L <br />A <br />R <br /> <br />P <br />O <br />W <br />E <br />R <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />NG <br />U <br />Y <br />E <br />N <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />46 <br />0 <br />9 <br /> <br />W <br /> <br />E <br />L <br /> <br />D <br />O <br />N <br /> <br />P <br />L <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SITE PLAN <br />DOC ID:ED8F10-3 <br />DATE:5/13/22 <br />CREATOR:B.H. <br />REVIEWER: <br />REVISIONS <br />PV-2 <br />4609 W El Don Pl - <br />10111143409/21/22
The URL can be used to link to this page
Your browser does not support the video tag.