Laserfiche WebLink
JOB NO.: U2880.1439.211 <br />SUBJECT: CONNECTION <br />PROJECT: De La Cruz, Eladio Residence <br />Calculate Uplift Forces on Connection <br />Pressure <br />(0.6 Dead -0.6 Wind) <br />(psf) <br />Max Trib. Width1 <br />(ft) <br />Max Trib. <br />Area2 <br />(ft2) <br />Max Uplift <br />Force <br />(lbs) <br />Zone 1 16.5 6.0 20.0 330 <br />Zone 2r 20.0 6.0 20.0 400 <br />Zone 2e, 3 21.8 6.0 20.0 436 <br />Calculate Connection Capacity <br /> Lag Screw Size [in]:5/16 <br />Cd:1.6 NDS Table 2.3.2 <br />Embedment3 [in]:3 <br />Grade: <br />Nominal Capacity [lbs/in]:205 NDS Table 12.2A <br />Number of Screws:1 <br />Prying Coefficient:1.4 <br />Total Capacity [lbs]:703 <br />Determine Result <br />Maximum Demand [lbs]: 436 <br />Lag Screw Capacity [lbs]: 703 <br />Result: Capacity > Demand, Connection is adequate. <br />Notes <br />1. 'Max Trib. Width' is the width along the rails tributary to the connection. <br />3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag <br />screw. Embedment in sheathing or other material is not effective. The length of the tapered tip is not part of the <br />embedment length. <br />2. 'Max Trib Area' is the product of the 'Max. Trib Width' and 1/2 the panel width/height perpendicular to the <br />rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 80". <br />SPF (G = 0.42) <br />4701 W Lucky Way <br />11/02/21