My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4713 1%2 W Floyd Cir - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Floyd Cir
>
4713 1/2 W Floyd Cir
>
4713 1%2 W Floyd Cir - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:43:48 PM
Creation date
5/30/2025 8:01:00 AM
Metadata
Fields
Template:
Plan
Permit Number
20177382
101111887
Full Address
4713 1/2 W Floyd Cir
Document Relationships
101111887 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Floyd Cir\4713 1/2 W Floyd Cir
20177382 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Floyd Cir\4713 1/2 W Floyd Cir
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
6&23(2):25. <br />INSTALL (6) SILFAB ELITE SIL-370 HC SOLAR ELECTRIC MODULES <br />AND (6) ENPHASE IQ8PLUS-72-2-US MICROINVERTERS ON THE <br />EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED <br />MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, <br />CONDUCTORS AND GROUNDING. INSTALL (1) AC COMBINER, <br />AND INSTALL OCPD IN SUB PANEL. <br />HOMEOWNER: THUY NGUYEN <br />ADDRESS: 4713 1/2 W. FLOYD CIRCLE <br />SANTA ANA, CA 92704 <br />DATE: 9/7/22DATE: 9/7/22 <br />(&262/$5 86$ <br />(/(&75,&$///& <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 <br />6<67(0 6,*1$*( <br />ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT <br />PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND <br />ATTACHED WITH WEATHERPROOF ADHESIVE OR <br />OTHER APPROVED METHOD. ALL LETTERS SHALL BE A <br />MINIMUM OF 3 8" HEIGHT AND ALL CAPITALIZED. <br />ALL CONDUIT, JUNCTION BOXES AND OTHER ENCLOSURES <br />SHALL BE MARKED AT 10' MAX INTERVALS AND AT ALL <br />BENDS, TERMINATIONS, SPLICES OR CONNECTIONS WITH <br />"WARNING: PHOTOVOLTAIC POWER SOURCE". <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH THE LINE <br />AND LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />TO BE INSTALLED AT ALL SERVICEABLE PANELS <br />OR BOXES AND AT ALL DISCONNECTS: <br />SERVICE POINT & <br />UTILITY METERING <br />PV SYSTEM DISCONNECT <br />FOR UTILITY OPERATION <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING SOURCES <br />WITH DISCONNECTS AS SHOWN. <br />ADDRESS: 4713 1/2 W. FLOYD CIRCLE, SANTA ANA, CA 92704 <br />SOLAR ARRAY <br />(ON ROOF) <br />N <br />TO BE INSTALLED ON THE OUTSIDE COVER <br />OF THE MAIN SERVICE DISCONNECT: <br />RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM <br />RATED AC OUTPUT CURRENT = 9.08 A <br />NOMINAL OPERATING AC VOLTAGE = 240 V <br />TO BE INSTALLED NEXT <br />TO THE SOLAR BREAKER: <br />WARNING <br />POWER SOURCE OUTPUT CONNECTION - <br />DO NOT RELOCATE THIS OVERCURRENT DEVICE <br />TO BE INSTALLED AT THE BACKFED <br />BREAKER SERVING THE PV SOLAR SYSTEM: <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TO BE INSTALLED ON THE FRONT OF THE <br />MAIN SERVICE DISCONNECT: <br />"SOLAR PV SYSTEM EQUIPPED WITH RAPID <br />SHUTDOWN" SHALL BE BLACK LETTERING <br />ON YELLOW BACKGROUND. THE <br />REMAINDER OF THE SIGN SHALL BE BLACK <br />LETTERING ON WHITE BACKGROUND. <br />6+((7 <br />127,&( <br />$1<&+$1*(67225 86(62)7+(6( <br />'2&80(176'5$:,1*6:,7+2877+( <br />:5,77(1&216(172)-(11,)(5 .(00(25 <br />6&277+$55,6$5(675,&7/<352+,%,7(' <br />2) <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />6<67(0 &$/&8/$7,216 <br />MODULE OPERATING CURRENT = 10.60 A <br />INVERTER MAX INPUT CURRENT = 15.00 A <br />10.60 A < 15.00 A, OK <br />MODULE OPERATING VOLTAGE = 34.95 V <br />INVERTER INPUT OPERATING VOLTAGE RANGE = 25 V - 58 V <br />25 V < 34.95 V < 58 V, OK <br />MODULE Voc = 41.75 V <br />VOLTAGE CORRECTION FACTOR = 1.14 <br />41.75 V (1.14) = 47.60 V <br />INVERTER MAX INPUT VOLTAGE = 60 V <br />47.60 V < 60 V, OK <br />MODULE Isc = 11.25 A <br />11.25 A (1.25)(1.25) = 17.58 A [Isc] <br />NUMBER OF MICROINVERTERS IN CIRCUIT #1 = 6 <br />INVERTER MAX OUTPUT CURRENT = 1.21 A <br />(6) (1.21 A) (1.25) = 9.08 A [Ic], USE 20 A BREAKER <br />TOTAL NUMBER OF MICROINVERTERS = 6 <br />(6) (1.21 A) (1.25) = 9.08 A [I], USE 20 A BREAKER <br />SUB PANEL BUS RATING = 125 A <br />SUB PANEL MAIN OCPD = 100 A <br />100 A + 20 A SOLAR OCPD = 120 A <br />125 A BUS (1.2) = 150 A <br />120 A < 150 A, OK <br />:,5(&$/&8/$7,216 <br />FROM THE MICROINVERTERS TO THE AC COMBINER: <br />AMBIENT TEMPERATURE = 34°C <br />TEMPERATURE ADDER FOR CONDUIT NOT OFFSET FROM ROOF = 33°C <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT <br />34°C + 33°C = 67°C = 0.58 <br />Ic = 9.08 A <br />9.08 A/0.58 = 15.66 A <br />SELECT WIRE SIZE WITH AMPACITY GREATER THAN 15.66 A, USE 12 AWG THWN-2 COPPER <br />WIRE WITH AN AMPACITY OF 30 A <br />SELECT CONDUIT FOR (2) 12 AWG THWN-2 & (1) 8 AWG GROUND = 1 2" EMT CONDUIT <br />FROM THE AC COMBINER TO THE SUB PANEL: <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT <br />34°C = 0.96 <br />I = 9.08 A <br />9.08 A/0.96 = 9.46 A <br />SELECT WIRE SIZE WITH AMPACITY GREATER THAN 9.46 A, USE 10 AWG THWN-2 COPPER <br />WIRE WITH AN AMPACITY OF 40 A <br />SELECT CONDUIT FOR (3) 10 AWG THWN-2 & (1) 10 AWG GROUND = 3 4" EMT CONDUIT <br />SUB PANEL <br />4713 1%2 W Floyd <br />Cir09/22/22
The URL can be used to link to this page
Your browser does not support the video tag.