My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
513 S Everglade Ave - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Everglade St
>
513 S Everglade St
>
513 S Everglade Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:43:49 PM
Creation date
5/30/2025 8:01:00 AM
Metadata
Fields
Template:
Plan
Permit Number
20177987
101112797
Full Address
513 S Everglade St
Document Relationships
101112797 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Everglade St\513 S Everglade St
20177987 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Everglade St\513 S Everglade St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(8)HANWHA Q CELL QPEAK DUO BLK ML-G10 400W ,MODULES WITH <br />(8)ENPAHSE IQ8PLUS-72-2-US(240V)(SI-1) <br />(1) BRANCH OF (8) MICRO-INVERTERS <br />(N)JUNCTION <br />BOX <br />2 1 <br />ENPHASE Q CABLE <br />DC CONDUCTORS <br />AC CONDUCTORS <br />3 <br />(N)125A END FED <br />MAIN PANEL <br />UTILITY <br />GRID <br />(N <br />) <br />1 <br />0 <br />0 <br />A <br /> <br />M <br />A <br />I <br />N <br />BR <br />E <br />A <br />K <br />E <br />R <br />PV BREAKER AT THE <br />OPPOSITE END OF <br />BUSBAR <br />20A 2P <br />PV BREAKER <br />EXISTING 120/240V 1PH 60HZ <br />METER#:SCE <br />222012-789643M <br />N <br />G <br />(E) GROUND <br />ELECTRODE <br />LOADS <br />3 <br />(N)30A AC <br />DISCONNECT <br />AC DISCONNECT <br />NON FUSED 30A, <br />120/240V, 2P <br />15A <br />AC COMBINER BOX <br />X-IQ-AM1-240-4 120/240 <br />NEMA 3R INSTALL <br />(1)20A PV 2P BREAKERS <br />(ONLY FOR SOLAR, NO <br />LOADS TO BE ADDED) <br />ENPHASE IQ <br />COMBINER 4 <br />20A <br />MODULE SPECIFICATION <br />MODEL <br />HANWHA Q CELL <br />QPEAK DUO BLK <br />ML-G10 400W <br />MODULE POWER @ STC 400W <br />OPEN CIRCUIT VOLTAGE:Voc 45.30V <br />MAX POWER VOLTAGE:Vmp 37.13V <br />SHORT CIRCUIT CURRENT:Isc 11.14A <br />MAX POWER CURRENT:Imp 10.77A <br />ADDRESS:513 S EVERGLADE ST, SANTA <br />ANA, CA 92704 <br />33.740912, -117.904046 <br />APN:109-78-142 <br />CUSTOMER INFORMATION <br />NAME:CECILIA TORRES <br />DATE:9/23/2022 <br />SCALE:AS NOTED REV:A <br />AHJ:CA - CITY OF SANTA ANA <br />UTILITY:SCE <br />PRN NUMBER:MAS-64170 <br />DRAFTED BY: <br />M.SAILESH <br />QC'ED BY:H.RAJ <br />PAPER SIZE:17"X11" <br />SOLARPLEX LLC <br />Dba MARAVILLA CONSTRUCTION <br /> License#:1056065 <br /> 5902 FIRESTONE BLVD <br /> SOUTH GATE, CA 90280 <br /> TEL:(562) 806-6000 <br /> FAX:(562) 806-4006 <br />SINGLE LINE DIAGRAM <br />E-01 <br />1. CONDUCTORS EXPOSED TO SUNLIGHT <br />SHALL BE LISTED AS SUNLIGHT <br />RESISTANT PER CEC 310.10(D). <br />2. CONDUCTORS EXPOSED TO WET <br />LOCATIONS SHALL BE SUITABLE FOR <br />USE IN WET LOCATIONS PER CEC <br />310.10(C). <br />3. MAXIMUM DC/AC VOLTAGE DROP SHALL <br />BE NO MORE THAN 2%. <br />4. ALL CONDUCTORS SHALL BE IN <br />CONDUIT UNLESS OTHERWISE NOTED. <br />5. BREAKER/FUSE SIZES CONFORMS TO <br />CEC 240.6 CODE SECTION. <br />6. AC GROUNDING ELECTRODE <br />CONDUCTOR SIZED PER CEC 250.66. <br />7. AMBIENT TEMPERATURE CORRECTION <br />FACTOR IS BASED ON CEC 690.31(A). <br />8. AMBIENT TEMPERATURE ADJUSTMENT <br />FACTOR IS BASED ON CEC 310.15(B)(2). <br />9. MAX. SYSTEM VOLTAGE CORRECTION IS <br />PER CEC 690.7. <br />10. CONDUCTORS ARE SIZED PER WIRE <br />AMPACITY TABLE CEC 310.15(B)(16). <br />ELECTRICAL NOTESSINGLE LINE DIAGRAM: DC SYSTEM SIZE - 3200W, AC SYSTEM SIZE - 2320W, CEC AC RATING:2883W <br />AC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >> <br />· REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF <br />INVERTERS = MAX CURRENT PER 690.8(A)(3) X 125% = MAX CURRENT PER <br />690.8(B)(1) <br />· CORRECTED AMPACITY CALCULATIONS: AMPACITY X TEMPERATURE DERATE <br />FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY PER <br />690.8(B)(2) <br />· DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(A)(3) <br /><DERATED CONDUCTOR AMPACITY <br />AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C <br />TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK <br />1 1.21 X 8 = 9.68 X 1.25 = 12.10A 30 X 0.87 X 1 =26.10A 12.10A <26.10A <br />2 1.21 X 8 = 9.68 X 1.25 = 12.10A 40 X 0.87 X 1 =34.80A 12.10A <34.80A <br />3 1.21 X 8 = 9.68 X 1.25 = 12.10A 40 X 0.87 X 1 =34.80A 12.10A <34.80A <br />CONDUIT SCHEDULE <br />TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND <br />1 NONE (2) 10AWG PV WIRE NONE (1) 6AWG BARE COPPER <br />2 3/4"EMT (2) 10AWG THHN/THWN-2 NONE (1) 8AWG THHN/THWN-2 <br />3 3/4"EMT (2) 10AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 (1) 8AWG THHN/THWN-2 <br />NOTE: <br />MAIN PANEL RATING:125A, MAIN BREAKER RATING:100A <br />120% RULE: (125AX1.2)-100A=50A =>ALLOWABLE BACKFEED IS 50A <br />OCPD CALCULATIONS: <br />INVERTER OVERCURRENT PROTECTION= <br />INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS <br />=1.21x1.25x8=12.10 A =>PV BREAKER = 20A <br />ALLOWABLE BACKFEED 50A =>20A PV BREAKER <br />THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS. <br />ELECTRICAL CALCULATION <br />MICRO INVERTER SPECIFICATIONS <br />MODEL <br />ENPAHSE <br />IQ8PLUS-72-2-US(240V)(SI- <br />1) <br />POWER RATING 290W <br />MAX OUTPUT CURRENT 1.21A <br />CEC WEIGHTED EFFICIENCY 97% <br />MAX NO OF MICRO <br />INVERTERS/BRANCH 13 <br />MAX DC VOLTAGE 60V <br />NOTE: <br />1. EACH MICRO INVERTER IS RAPID SHUTDOWN COMPLIANT. <br />2. MAIN PANEL UPGRADE:REPLACE EXISTING MAIN SERVICE PANEL WITH NEW <br />125/100A MAIN PANEL. <br />3. NEW SERVICE PANEL MUST BE COMBINATION/ALL-IN-ONE, AND METER AND MAIN <br />CANNOT BE SEPARATE. <br />4. 125A SERVICE REQUIRES A MINIMUM 6 AWG CONDUCTOR TO 10' OF UNDERGROUND <br />METAL WATER PIPE ELECTRODE. BOND ON THE INSIDE/OUTSIDE WITHIN FIRST 5' OF <br />WHERE THE WATER ENTERS THE BUILDING. AN ADDITIONAL CONNECTION UFER OR 2 <br />NEW RODS IS NEEDED - LOCATED 6' FROM OTHER ELECTRODES. WATER PIPE MAY NOT <br />BE USED TO BOND ANY ELECTRODES UNLESS BURIED OR ENCASED, ELECTRODE <br />CONNECTIONS MUST BE ACCESSIBLE. <br />5. LISTED COMBINATION OVERHEAD AND UNDERGROUND FEED SERVICE BOXES <br />REQUIRED. <br />513 S Everglade <br />Ave12/20/22
The URL can be used to link to this page
Your browser does not support the video tag.