My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
534 S Sycamore St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Sycamore St
>
534 S Sycamore St
>
534 S Sycamore St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 9:11:50 AM
Creation date
5/30/2025 8:01:03 AM
Metadata
Fields
Template:
Plan
Permit Number
20175697
101109797
Full Address
534 S Sycamore St
Street Number
534
Street Direction
S
Street Name
Sycamore
Street Suffix
St
Document Relationships
101109797 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Sycamore St\534 S Sycamore St
20175697 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Sycamore St\534 S Sycamore St
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
352
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
6 Electrical ConnectionSMA Solar Technology AG <br />Installation Manual SBxx-1SP-US-41-IA-xx-12 45 <br />14. Ensure the conductors are plugged into the terminal <br />points (round openings) as far as is will go and not <br />into the actuation shafts (rectangular openings).AC-out SPSL N <br />AC-out SPSL N <br />15. Ensure that the terminal points are allocated to the correct conductors. <br />16. Ensure that the conductors are plugged completely into the terminal points up to their <br />insulation. <br />17. Install outlet in desired position (e.g. next to the inverter or as switch/outlet combination <br />optionally at short distance from the inverter (to max. 10 m (393.7 in))). <br />18. Connect the other end of the cable using it directly as energy supply to the outlet. <br />Connect the switch for secure power supply operation <br />Requirements for the conductors: <br />☐ Conductor cross-section: 0.2 mm² to 2.5 mm² (24 AWG to 14 AWG) <br />☐ The conductor type and wiring method must be appropriate for the application and location. <br />☐ Maximum length of conductors: 10 m (393.7 in) <br />Procedure: <br />1. Remove the sealing plug from the opening for connecting the switch for secure power supply <br />operation. <br />2. Insert the conduit fitting into the opening and tighten from the inside using the counter nut. <br />3. Attach the conduit to the conduit fitting. <br />4. Guide the conductors into the inverter. <br />5. Strip off the conductor insulation by min. 6 mm (0.24 in) to max. 10 mm (0.39 in). <br />6. Connect the conductors to the 2-pole terminal <br />blocks. Ensure that the conductors are plugged <br />completely into the terminal points up to their <br />insulation. <br />EN <br />G <br />L <br />I <br />S <br />H <br />534 S Sycamore St <br />- 10110979707/01/22
The URL can be used to link to this page
Your browser does not support the video tag.