My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
534 S Sycamore St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Sycamore St
>
534 S Sycamore St
>
534 S Sycamore St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:44:46 PM
Creation date
5/30/2025 8:01:03 AM
Metadata
Fields
Template:
Plan
Permit Number
20175697
101109797
Full Address
534 S Sycamore St
Document Relationships
101109797 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Sycamore St\534 S Sycamore St
20175697 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Sycamore St\534 S Sycamore St
Jump to thumbnail
< previous set
next set >
Text box
ID:
1
Creator:
Import Agent
Created:
5/30/2025 10:02 AM
Modified:
5/30/2025 9:38 AM
Text:
http://www.imopc.com
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
352
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
www.imopc.com 9 <br />It is because of this that the IMO Solar Isolator range is constructed of materials that significantly reduce the risk of a fire hazard and in particular <br />our enclosed installation style products for which the main plastic enclosure is rated at UL 94V-0 and the handles are UL 94V-2 rated. The <br />classification criteria for each of these ratings is found in of the UL 94 Table 8.1 (see extract below). <br />The installation requirements and environments of PV systems can vary significantly and the IMO Solar Isolator has been designed <br />such that it can offer a wide range of configurations depending upon the users’ requirement. Also the IMO Solar Isolator range includes <br />models that, when mounted in accordance with their respective instructions and with the appropriate IMO handle, offer suitable <br />protection up to IP66 (EN 60529) and NEMA 4X (Nema 250, UL508). <br />With the advent of more worldwide installations and the requirements laid down in many country’s national wiring publications for the use of <br />DC switches in PV installations, the IMO Solar Isolators have also been assessed and tested under the latest UL standard UL508i which has been <br />specifically written to cover the use of “Manual Disconnect Switches intended for use in Photovoltaic Systems”. <br />This UL508i standard specifically covers switches rated up to 1500 V that are intended for use in an ambient temperatures of -20 °C to +50°C, <br />and that are suitable for use on the load side of PV branch protection devices. In order to comply with this standard the IMO DC Isolators has to <br />pass an overload test, at +50°C, of 50 cycles at 200% of rated current; followed by an endurance test of 6000 cycles (6 cycles/min) at rated load <br />(Ith) and a further 4000 cycles with no current. <br />The IMO DC Isolator has successfully attained certification under the UL508i standard and as such is suitable for use as a disconnection method <br />for the isolation of the output of DC PV array where it is to be connected to a DC/AC inverter. <br />Criteria conditions V-0 V-1 V-2 <br />Afterflame time for each individual specimen t1 or t2 <10s <10s <30s <br />Total afterflame time for any condition set (t1 plus t2 for the 5 specimens <50s <250s <250s <br />Afterflame puts afterglow time for each individual specimen after the second flame application (t2+t3)<30s <60s <60s <br />Afterflame or afterglow of any specimen up to the holding clamp No No No <br />Cotton indicator ignited by flaming particles or drops No No Yes <br />Examples of Typical PV Installations <br />Single String System – 3kW Output Single Phase <br />Consider two potential configurations for a typical 3kW system which would supply 13A at 230VAC: <br />Inverter: Input: 600VDC (VOC), 16A (IDC), 32A (IDC max) Output: 230VAC (VAC), 13A (IAC), 17.2A (IAC max) <br />Solar Panel: 60V (VOC), 8A (ISC) No. of panels: 8 <br />Calculation: V = 8 x 60 x 1.15 = 552V I = 8 x 1.25 = 10A <br />For this configuration, the IMO SI16-PEL64R-2 rated at 16A for 700VDC is suitable for the DC switch and the PE69-3020 rated at 20A is <br />suitable for the AC switch. <br />Inverter: Input: 750VDC (VOC), 15A (IDC), 28A (IDC max) Output: 230VAC (VAC), 13A (IAC), 16A (IAC max) <br />Solar Panel: 60V (VOC), 8A (ISC) No. of panels: 10 <br />Calculation: V = 10 x 60 x 1.15 = 895.62V I = 8 x 1.25 = 10A <br />For this configuration, the IMO SI25-PEL64R-2 would still be suitable as it is rated at 16A for 800VDC, however the IMO SI25-PEL64R-2 rated at <br />16A for 900VDC would allow for a greater margin of safety. The PE69-3020 rated at 20A is suitable for the AC switch. <br />L <br />N <br />E <br />Existing AC <br />Equipment <br /> DC Isolator Inverter AC Isolator <br /> 600V: SI16-PEL64R-2 3kW PE69-3020 <br /> 750V: SI25-PEL64R-2 PE69-3020 <br /> PV Arrays <br />+ + + + <br />- - - - <br />+ + + + <br />- - - - <br />L <br />N <br />E <br />534 S Sycamore St <br />- 10110979707/01/22
The URL can be used to link to this page
Your browser does not support the video tag.