My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
534 S Sycamore St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Sycamore St
>
534 S Sycamore St
>
534 S Sycamore St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 9:11:50 AM
Creation date
5/30/2025 8:01:03 AM
Metadata
Fields
Template:
Plan
Permit Number
20175697
101109797
Full Address
534 S Sycamore St
Street Number
534
Street Direction
S
Street Name
Sycamore
Street Suffix
St
Document Relationships
101109797 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Sycamore St\534 S Sycamore St
20175697 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Sycamore St\534 S Sycamore St
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
352
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
4 Vue d’ensemble des produitsSMA Solar Technology AG <br />Instructions d’installation SBxx-1SP-US-41-IA-xx-12 175 <br />L’onduleur dispose de fonctions pour le soutien du réseau. En cas de panne de courant alternatif ou <br />d’actionnement du sectionneur AC, l’onduleur reste dans le réseau électrique public pendant une <br />durée définie (Ride Through) et attend le retour de la tension. Si la tension du réseau n’est pas <br />rétablie dans la durée définie, l’onduleur se coupe du réseau électrique public et un arrêt rapide <br />(Rapid Shutdown) se déclenche. <br />Par défaut, la fonction à arrêt rapide (Rapid Shutdown) est désactivée. La fonction à arrêt rapide <br />(Rapid Shutdown) ne doit être activée que lorsque des interrupteurs de module photovoltaïque <br />homologués sont installés dans les panneaux ou entre les panneaux photovoltaïques et l’onduleur. <br />La fonction à arrêt rapide (Rapid Shutdown) peut être activée via l’interface utilisateur pendant ou <br />après la mise en service de l’onduleur. Il suffit de sélectionner le mode de fonctionnement adapté <br />aux interrupteurs de module photovoltaïque. Si la fonction à arrêt rapide (Rapid Shutdown) est <br />activée mais qu’aucun interrupteur de module photovoltaïque n’a été installé, l’onduleur ne peut <br />pas décharger le conducteur d’entrée DC en cas d’arrêt rapide. Dans ce cas, l’onduleur risque <br />d’être endommagé. <br />AVERTISSEMENT - CET ÉQUIPEMENT À ARRÊT RAPIDE DE L’ÉNERGIE PHOTOVOLTAÏQUE NE <br />DISPOSE PAS DE TOUTES LES FONCTIONS D’UN SYSTÈME COMPLET À ARRÊT RAPIDE. CET <br />ÉQUIPEMENT PHOTOVOLTAÏQUE À ARRÊT RAPIDE DOIT ÊTRE ÉQUIPÉ D’AUTRES DISPOSITIFS <br />AFIN DE CONSTITUER UN SYSTÈME COMPLET À ARRÊT RAPIDE SATISFAISANT AUX <br />EXIGENCES NEC (NFPA 70) CONCERNANT LES CÂBLES DE RACCORDEMENT SURVEILLÉS À <br />L’EXTÉRIEUR DU GÉNÉRATEUR PHOTOVOLTAÏQUE. L’INSTALLATION D’APPAREILS <br />SUPPLÉMENTAIRES À L’INTÉRIEUR OU À L’EXTÉRIEUR DE L’INSTALLATION RISQUENT D’AVOIR <br />UNE INFLUENCE NÉGATIVE SUR LE FONCTIONNEMENT DU SYSTÈME PHOTOVOLTAÏQUE À <br />ARRÊT RAPIDE. L’INSTALLATEUR EST TENU DE RESPECTER LES EXIGENCES FONCTIONNELLES <br />D’ARRÊT RAPIDE LORS DU MONTAGE DE L’INSTALLATION PHOTOVOLTAÏQUE. CES <br />APPAREILS DOIVENT ÊTRE INSTALLÉS CONFORMÉMENT AUX INSTRUCTIONS <br />D’INSTALLATION DU FABRICANT. <br />Fonctionnement en parallèle des entrées DC A et B <br />La possibilité d’utiliser en parallèle les entrées DC A et B de l’onduleur et d’y raccorder en parallèle <br />jusqu’à 3 strings vous est offerte. Contrairement au fonctionnement normal, cela permet de <br />raccorder jusqu’à 3 strings aux onduleurs munis de 2 entrées DC, et jusqu’à 4 strings directement <br />aux onduleurs disposant de 3 entrées DC. L’onduleur détecte automatiquement si les entrées DC A <br />et B sont utilisées en parallèle. <br />Alimentation de secours <br />Vous pouvez raccorder à l’onduleur une prise de courant externe et un interrupteur pour la prise. <br />La prise de courant sert à alimenter une charge avec du courant produit par l’installation <br />photovoltaïque en cas de panne du réseau. L’enclenchement de la prise de courant par <br />l’interrupteur active l’alimentation de la charge en courant produit par l’installation photovoltaïque. <br />FR <br />A <br />N <br />Ç <br />A <br />I <br />S <br />534 S Sycamore St <br />- 10110979707/01/22
The URL can be used to link to this page
Your browser does not support the video tag.