Laserfiche WebLink
REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />DO <br />U <br />G <br /> <br />R <br />I <br />S <br />K <br />61 <br />0 <br /> <br />E <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />C <br />L <br />A <br />R <br />A <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />, <br /> <br />U <br />S <br />A <br />ANSI B <br />11" X 17" <br />DATE DESCRIPTION <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-8 <br />CONTRACTOR NAME <br />CONTRACTOR INFORMATION <br />8001 CANOGA AVE #B <br />CANOGA PARK, CA 91304 <br />PHONE: 1(818) 564-4820 <br />COASTAL BUILDERS <br />610 E. SANTA CLARA AVE. <br />SANTA ANA, CA 92706 <br />(714) 234-9160 <br />CALIFORNIA <br />LIC# 623480- B <br />WIRING <br />CALCULATIONS <br />ELECTRICAL NOTES <br />DC CONDUCTOR AMPACITY CALCULATIONS: <br />ARRAY TO JUNCTION BOX: <br />DC CONDUCTOR AMPACITY CALCULATIONS: <br />FROM JUNCTION BOX TO INVERTER: <br />AC CONDUCTOR AMPACITY CALCULATIONS: <br />INVERTER TO MAIN PANEL <br />1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. <br />3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS <br />POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. <br />5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, <br />SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. <br />6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM <br />ACCORDINGLY. <br />7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING <br />CLIP MANUFACTURER'S INSTRUCTION. <br />9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br />10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE <br />INVERTER SPECIFICATIONS <br />MANUFACTURER / MODEL # <br />NOMINAL AC POWER <br />NOMINAL OUTPUT VOLTAGE <br />MAX. CONTINUOUS OUTPUT CURRENT <br />NUMBER OF CURRENT <br />CARRYING CONDUCTORS IN <br />EMT <br />4-6 <br />7-9 <br />10-20 <br />PERCENT <br />OF <br />VALUES <br />.80 <br />.70 <br />.50 <br />SOLAREDGE SE7600H-US000BNU4 <br />7.6 KW <br />240 VAC <br />32A <br />OPTIMIZERS SPECIFICATIONS <br />MANUFACTURER / MODEL # <br />MAX. OUTPUT CURRENT <br />MAX. INPUT CURRENT <br />MAX. INPUT VOLTAGE <br />SOLAREDGE POWER OPTIMIZER P320 <br />15A <br />8.8A <br />48Vdc <br />SOLAR MODULE SPECIFICATIONS <br />MANUFACTURER / <br />MODEL # <br />VMP <br />IMP <br />VOC <br />ISC <br />HANWHA Q.CELLS Q.PEAK DUO <br />BLK-G5 320W <br />MODULE DIMENSION <br />MODULE TEMPERATURE COEFFICIENT OF Voc <br />33.32V <br />9.60A <br />40.13V <br />10.09A <br />66.3"L x 39.4"W x 1.26"D (In Inch) <br />-0.28%/°C <br />EXPECTED WIRE TEMP (In Celsius)31° <br />TEMP. CORRECTION PER TABLE (310.16)0.96 <br />NO. OF CURRENT CARRYING CONDUCTORS 4 <br />CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 <br />CIRCUIT CONDUCTOR SIZE 10 AWG <br />CIRCUIT CONDUCTOR AMPACITY 40A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) <br />18.75A <br />1.25 X OPTIMIZER OUTPUT <br />DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 <br />30.72ATEMP. CORRECTION PER TABLE (310.16) X <br />CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT <br />CONDUCTOR AMPACITY <br />Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and <br />ampacity <br />EXPECTED WIRE TEMP (In Celsius)31° <br />TEMP. CORRECTION PER TABLE (310.16)0.96 <br />NO. OF CURRENT CARRYING CONDUCTORS 4 <br />CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 <br />CIRCUIT CONDUCTOR SIZE 10AWG <br />CIRCUIT CONDUCTOR AMPACITY 40A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) <br />18.75A <br />1.25 X OPTIMIZER OUTPUT <br />DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 <br />30.72ATEMP. CORRECTION PER TABLE (310.16) X <br />CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT <br />CONDUCTOR AMPACITY <br />Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and <br />ampacity <br />No. OF INVERTER 1 <br />EXPECTED WIRE TEMP (In Celsius)31° <br />TEMP. CORRECTION PER TABLE (310.16)0.96 <br />NO. OF CURRENT CARRYING CONDUCTORS 3 <br />CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1 <br />CIRCUIT CONDUCTOR SIZE 8AWG <br />CIRCUIT CONDUCTOR AMPACITY 50A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) <br />40A <br />1.25 X MAX INVERTER OUTPUT CURRENT <br />DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 <br />44ATEMP. CORRECTION PER TABLE (310.16) X <br />CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT <br />CONDUCTOR AMPACITY <br />Result should be greater than (40.00A) otherwise less the entry for circuit conductor size and <br />ampacity <br />AMBIENT TEMPERATURE SPECS <br />RECORD LOW TEMP 2° <br />AMBIENT TEMP (HIGH TEMP 2%)31° <br />CONDUIT HEIGHT 7/8" <br />ROOF TOP TEMP 53° <br />CONDUCTOR TEMPERATURE RATE 90°75°/ <br />610 E Santa Clara <br />Ave11/09/21