Laserfiche WebLink
Date: 8/17/2022 <br />Single Family Dwelling Electrical Service Load Calculation <br />1. General Lighting Loads <br />Dwelling 1822 sq. ft X 3 VA =5466 VA <br />Small appliance loads -220-16(a) 1500 VA X 2 Circuits = 3000 VA <br />Laundry load - 220-16 (b) 1500 VA X 1 Circuits = 1500 VA <br />General Lighting Total 9,966 VA <br />2. Cooking Equipment Loads - Nameplate Value <br />Range 0 Amps =0 VA <br />Cooktop Amps =0 VA <br />Oven Amps =0 VA <br />Cooking Equipment Total 0 VA <br />3. Electric Dryer 220-18 (Nameplate, 5000 VA minimum) <br />Dryer qty: 0 VA <br />Dryer Total 0 VA <br />4. Other Loads <br />Subpanel @ Amps X 240 Volts =0 VA <br />Garbage @ 20 Amps X 120 Volts =2400 VA <br />Dishwasher @ 20 Amps X 120 Volts =2400 VA <br />Microwave @ 20 Amps X 120 Volts =2400 VA <br />AC @ 30 Amps X 240 Volts =7200 VA <br />pool @ 20 Amps X 120 Volts =2400 VA <br />Washer @ 20 Amps X 120 Volts =2400 VA <br />Fridge @ 20 Amps X 120 Volts =2400 VA <br />Freezer @ 30 Amps X 120 Volts =3600 VA <br />lights @ 75 Amps X 120 Volts =9000 VA <br />@ Amps X 120 Volts =0 VA <br />Fixed Appliance Total 34,200 VA <br />5. Subtotal (add all above lines) 44,166 VA <br />6. First 10,000 VA X 100%10,000 VA <br />Remaining 34,166 VA X 40% =13,666 VA <br />7. Total Load 23,666 VA <br />10. Existing Minimum Service Size = Total Load in VA =98.61 Amps <br />625 W Columbine <br />Ave - Rev <br />#2017748409/28/22