LA <br />B <br />E <br />L <br />I <br />N <br />G <br />IE <br />- <br />0 <br />5 <br />LABELING NOTES <br />1. LABELING REQUIREMENTS BASED ON THE CALIFORNIA ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD <br />1910.145, CCR TITLE 8 §3340, ANSI Z535.4-2011 <br />2. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. <br />3. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. <br />4. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. <br />5. ALERTING WORDS TO BE COLOR CODED. "DANGER" WILL HAVE RED BACKGROUND; "WARNING" WILL HAVE ORANGE BACKGROUND; <br />"CAUTION" WILL HAVE YELLOW BACKGROUND.[ANSI Z535.4-2011] <br />DIRECTORY <br />A PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF ALL ELECTRIC <br />POWER SOURCE DISCONNECTING MEANS SHALL BE PROVIDED AT EACH SERVICE <br />EQUIPMENT LOCATION AND PV SYSTEM DISCONNECTING MEANS IN ACCORDANCE <br />WITH CEC 705.10. PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE <br />INSTALLED IN BATHROOMS [CEC 690.4(E)] <br />AT RAPID SHUTDOWN SYSTEM <br />[CEC 690.56(C)(1)(A)] <br />LABEL 1 <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING <br />METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE <br />SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, <br />CEILINGS, OR FLOORS. [CEC 690.31(G)(3)] <br />LABEL 5 <br />LABELING <br />LETTERING TO BE AT LEAST 3 8" WHITE <br />ON RED BACKGROUND; REFLECTIVE, UV <br />RESISTANT STICKERS. [CEC 690.31(G)(4)] <br />AT POINT OF CONNECTION; LABEL, <br />SUCH AS LABEL 2 OR LABEL 3 MUST <br />IDENTIFY PHOTOVOLTAIC SYSTEM <br />[CEC 705.12(B)(3)] <br />DUAL POWER SOURCES <br />SECOND SOURCE IS <br />PHOTOVOLTAIC SYSTEM <br />WARNING <br />LABEL 3 <br /> RATED AC OUTPUT CURRENT: 8.46A <br /> NOMINAL OPERATING AC VOLTAGE: 240V <br />LABEL 2 <br />AT EACH AC DISCONNECTING MEANS <br />[CEC 690.13(B) AND 690.54] <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />AT RAPID SHUTDOWN SWITCH <br />[CEC 690.56(C)(3)] <br />LABEL 7 <br />JA <br />Y <br />. <br />P <br />E <br />P <br />I <br />T <br />O <br />LABEL 4 <br />LABEL 6 <br />AT POINT OF INTERCONNECTION <br />OVERCURRENT DEVICE <br />[CEC 705.12(B)(2)(3)(B)] <br />AT MAIN SERVICE PANEL, PULL BOXES <br />[CEC 705.12(B)(3)] <br />POWER SOURCE OUTPUT <br />CONNECTION - DO NOT RELOCATE <br />THIS OVERCURRENT DEVICE <br />WARNING <br />PHOTOVOLTAIC SYSTEM <br />CIRCUIT IS BACKFED <br />CAUTION 38 <br />5 <br />5 <br /> <br />R <br />A <br />I <br />L <br />R <br />O <br />A <br />D <br />CA <br />N <br />Y <br />O <br />N <br /> <br />R <br />D <br />. <br /> <br />S <br />T <br />E <br /> <br />2 <br />- <br />2 <br />9 <br />CA <br />N <br />Y <br />O <br />N <br /> <br />L <br />A <br />K <br />E <br />, <br />CA <br /> <br />9 <br />2 <br />5 <br />8 <br />7 <br />CS <br />L <br />B <br /># <br />: <br /> <br />1 <br />0 <br />7 <br />4 <br />4 <br />6 <br />9 <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />I <br />N <br />F <br />O <br />R <br />M <br />A <br />T <br />I <br />O <br />N <br />SA <br />U <br />L <br /> <br />D <br />E <br />L <br />G <br />A <br />D <br />O <br />62 <br />5 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />B <br />R <br />O <br />A <br />D <br />W <br />A <br />Y <br /> <br />un <br />i <br />t <br /> <br /># <br /> <br />3 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />CA <br />, <br />9 <br />2 <br />7 <br />0 <br />1 <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />FI <br />N <br />A <br />N <br />C <br />E <br /> <br />T <br />Y <br />P <br />E <br />: <br /> <br />S <br />U <br />N <br />N <br />O <br />V <br />A <br />DA <br />T <br />E <br />: <br />7 <br />/ <br />2 <br />1 <br />/ <br />2 <br />0 <br />2 <br />2 <br />625 S Broadway <br />11/03/22