LAG SCREW ANALYSIS <br />Loads <br />Wind Pressures qz = -56.30 psf <br />Solar Panel Load QD = 3 psf <br />Panel Length l = 5.761 ft <br />Panel Width b 3.4088 ft <br />Attachment Spacing s = 6 ft <br />Portrait <br />Tributary Area At = 17.28 ft2 <br />Wind Load P W = qz * At = -973 lbs <br />Dead Load P D = Q D * At = 51.85 lbs <br />Uplift Pa = 0.6 P D + 0.6 Pw = -553 lbs <br />Landscape <br />Tributary Area At = b * s = 10.226 ft2 <br />Wind Load P W = qz * At = -576 lbs <br />Dead Load P D = Q D * At = 30.679 lbs <br />Uplift Pa = 0.6 P D + 0.6 Pw = -327 lbs <br />Lag Screw 5/16" x 5" <br />Specific Gravity of Lumber SG = 0.50 (Douglas Fir-Larch) <br />Diameter of Lag Screw D = 5/16 in <br />Withdraw Design /in 1800*SG 3/2 *D 3/4 = 266 lbs/in <br />Depth of Embedment lp = 2.50 in <br />Total Nominal Withdrawal Value W = W * l p = 665 lbs <br />Load Duration Factor CD = 1.6 <br />Withdrawal Design Value W' = W * C D = 1064 lbs <br />Demand Capacity Ratio DCR = Pa / W' = 0.52 < 1 OK <br />643 E. Flora Unit <br />#204/14/22