PHOTOVOLTAIC GENERAL NOTES <br />· ALL MATERIALS, EQUIPMENT. INSTALLATION AND WORK · ALL GROUNDED (NEUTRAL) CONDUCTORS INSULATION SHALL BE SOLID WHITE, GRAY <br />PERFORMED SHALL BE IN ACCORDANCE WITH THE FOLLOWING OR WITH 3-WHITE STRIPES (NEC 2000 200 7 400 22], ALL GROUNDING CONDUCTORS COUNT/ ELECTRONIC STAMP <br />CODES SHALL BE OF BARE WIRE WITHOUT COVERING OR WITH INSULATION OF GREEN OR <br />- 2019 CRC /2018 IBC GREEN WITH YELLOW STRIPES NEC 250 119 & 400 23 THE COLOR OF UNGROUNDED <br />.2019 CRC 12018 IRC CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED. (NEUTRAL) AND GROUNDING <br />-2019 CEC /2017 NEC CONDUCTORS [NEC 310 110(0)) <br />· 2019 CMC /2018 IMC <br />2019 CPC /2019 PC MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND <br />OVERCURRENT PROTECTION IS 10FT [NEC 705 31]2019 CFC /2010 IFC <br />-2019 BUILDING ENERGY EFFICIENCY STANDARDS CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE <br />OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL BE IN <br />· ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ACCORDANCE WITH NEC 705 12(B) <br />ELECTRICAL TESTING LABORATORY AND L.A. TEST LAB <br />EQUIPMENT INSTALLED SHALL BE PER ITS LISTING REQUIREMENTS DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS CONDUITS_ <br />AND THE MANUFACTURERS INSTRUCTIONS (NEC 110.2. 110.3,ENCLOSURES OR CABLE SHEATHINGS [NEC 690 3110)] <br />6904(B/.690 12(D)) <br />METALLIC TYPE RACEWAYS CONDUITS.ENCLOSURES, AND CABLE SHEATHS <br />ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED. INCLUDING CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND MUST BE BONDED IN <br />ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES ACCORDANCE WITH NEC 250 97. <br />ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE CONNECTORS THAT ARE <br />READILY ACCESSIBLE AND OPERATING AT OVER .30 -VOLTS SHALL REQUIRE A TOOL TOACCORDANCE WITH NEC ARTICLE 250.OPEN AND MARKED "DO NOT DISCONNECT UNDER LOAD" OR NOT FOR CURRENT <br />INTERRUPTING " (NEC 690 331C18 (E)(2)1 <br />ALL PV CIRCUITS CONNECTED AND EQUIPMENT SHALL BE <br />PROTECTED AGAINST OVERCURRENT, OVERCURRENT DEVICES · FOR PV MODULES EQUIPMENT GROUNDING CONDUCTOR (EGC) SMALLER THAN46.AWG <br />SHALL BE LISTED FOR USE IN PV SYSTEMS OVERCURRENT SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY AN IDENTIFIED RACEWAY OR CABLE <br />PROTECTIVE DEVICES SHALL NOT BE REQUIRED FOR CIRCUITS ARMOR UNLESS INSTALLED WITHIN HOLLOW SPACES OF THE FRAMING MEMBERS OF <br />WITH SUFFICIENT AMPACITY FOR THE HIGHEST AVAILABLE BUILDINGS OR STRUCTURES AND WHERE NOT SUBJECT TO PHYSICAL DAMAGE [NEC <br />CURRENT CIRCUITS CONNECTED TO CURRENT LIMITED SUPPLIES 69046 250_120(C)] <br />AND ALSO CONNECTED TO SOURCES HAVING HIGHER CURRENT <br />AVAILABILITY SHALL BE PROTECTED AT THE HIGHER CURRENT · THE INTERCONNECTION POINT SHALL BE ON THE SUPPLY SIDE OF ALL GROUND-FAULT <br />SOURCE CONNECTION [NEC 690 91 PROTECTION EQUIPMENT [NEC 705321 <br />DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID · CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT <br />LOCATED UNDER THE MODULES MUST BE PROTECTED [NEC 3004]SHUTDOWN INITIATION) SHALL BE LOCATED IN A READILY <br />ACCESSIBLE LOCATION NEAR THE EQUIPMENT [NEC 690 13 690 15] · FOR ELECTRICAL SERVICE REPLAC,EMENTS, BONDING TO THE METAL PIPES OF <br />NATURAL GAS HOT WATER AND COLD WATER MUST BE PROVIDED [NEC 250 104] <br />· RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH NEC 690 12 <br />GROUNDING ROD ELECTRODES SI IALL BE INSTALLED a-FT MINIMUM IN CONTACT WITt I <br />ENERGY STORAGE SYSTEM TERMINALS LOCATED MORE THAN 5 SOIL AND MINIMUM 5/8 -INCH DIAMETER (NEC 250 52(A)(5) 250.53(G)] <br />FEET AWAY OR ON OPPOSITE SIDE OF WALL FROM CONNECTED <br />EQUIPMENT MUST HAVE DISCONNECTING MEANS IN ACCORDANCE THE MARKINGS 'WARNING PITOTOVOL TAIC POWER SOURCE' FOR DC RACEWAYS AND <br />WITH NEC 706.7(E) AND LABELED PER 706 7I0) A SECOND CABLE ASSEMBLIES MUST BE NO MORE THAN /0-FT 00 AND IS SEPARATED BY <br />DISCONNECTING MEANS LOCATED AT THE CONNECTED ENCLOSURES WALLS PARTITIONS CEILINGS FLOORS, OR BENDS ABOVE OR BELOW <br />EQUIPMENT SHALL BE INSTALLED WHERE THE DISCONNECTING PENETRATIONS. [NEC 690 31(G)(318(411 <br />MEANS AT THE ESS END OF THE CIRCUIT IS NOT WITHIN SIGHT WORKING CLEARANCES TOOT PROVIDED AT NEW AND EXISTING ELECTRICAL <br />EQUIPMENT [NEC 11026]· THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY <br />DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL · POWER PRODUCTION SYSTEMS AND At L ASSOCIATED WIRING AND <br />PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN INTERCONNECTIONS OPERATING IN PARALLEL WITH A PRIMARY POWER SOURCE SHALL <br />RESTORED (NEC 705 40]BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC 690 41C) 7058) <br />ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LABELS SHALL BE REFLECTIVE AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE <br />LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND FOR A MINIMUM HEIGHT OF 3'8 IN WHITE ON A RED BACKGROUND [NEC 690.31(G1(4)] <br />THE APPLICATION [NEC 690 31(C) THROUGH (F). 310 10(D)] <br />IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN <br />INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES ACCORDANCE WITH NEC 690 56(C) <br />SHALL BE USE 2 OR PV.WIRE TYPE FOR PV SYSTEMS (UL 4703 <br />854 LISTED) [NEC 690 31(C))· SMOKE ALARMS AND CARBON mONOxIDE ALARMS ARE REQUIRED 10 BE RE ['ROE! ! I ED <br />ONTO THE EXISTING DWELLING AS PER THE 2019 CRC THESE SMOKE ALARMS ARE <br />REQUIRED TO BE IN ALL BEDROOMS OUTSIDE EACH BEDROOM AT LEAST ONE ONFINE STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS .AND <br />EACi I FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUPED TO BE <br />AND TERMINALS TO ENSURE A THOROUGHLY GOOD CONNECTION RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE <br />WITHOUT DAMAGING THE CONDUCTORS [NEC 110 14(A)]HOUSE .(CRC 314 315) <br />FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTIONS <br />WITH TERMINALS LUGS DEVICES, OR CONNECTORS THAT ARE 314 AND 315 TO BE VERIFIED AND INSPECTED BY THE INSPECTOR IN THE FIELD <br />IDENTIFIED AND LISTED FOR SUCH USE [NEC 690 3111-1). 110 14] <br />· A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH Cal-OSHA <br />ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END REGULATIONS, SECURED AND EXTENDING 3-FT ABOVE THE ROOF <br />AND GROUPED FOR UNIQUE IDENTIFICATION [NEC 690 3163)1 · ALL OF THE REQUIRED MARKINGS, SIGNS AND LABELS MUST BE INSTALLED ON ALL <br />ALL EXTERIOR CONDUIT FITTINGS, AND BOXES SHALL BE RAIN EQUIPMENT PRIOR TO ANY INSPECTIONS <br />TIGHT AND APPROVED FOR USE IN WET LOCATIONS [NEC 314.15] <br />— <br />· 2 <br />I—(/) <br />cnc0 — <br />OD < <br />C·i <br />7-1, - <br />· > <br />O 0 <br />0 c'n <br />0 2cs1 · g <br />C <br />O <br />V <br />E <br />R <br /> <br />PA <br />G <br />E <br /> <br />;PI <br />1AOF 11 <br />801 E Borchard <br />Ave04/13/22