Laserfiche WebLink
SIZE(kW) <br />MODULE: <br />SYSTEM SPECIFICATIONS <br />3.200 <br />7 <br />(8) HANWHA 0 CELLS 0 PEAK DUO BLK <br />ML-G10.114- 400 <br />INVERTER(S):(8) ENPHASE IQ7PLUS-72-2-US <br />INVERTER TYPE: <br />STRING SCHEDULE <br />MICRO-INVERT ER <br />1 CIRCUIT(S) OF 8 MODULES <br />SYSTEM WEIGHT(LBS)428 00 <br />ARRAY AREA(SQ FT)168 97 <br />ARRAY AZIMUTHC)/ 188. 278 <br />LBS/SQ FT 1 253 <br />BUILDING SPECIFICATIONS <br />TYPE SFD <br />STORIES: <br />TIHJILDING HEIGHT(FT ): <br />BUILDING(S0 FT) <br />ROOF SLOPES("): <br />12 <br />1548 <br />1 18 <br />ROOF FRAME MEMBER <br />O C SPACING(IN) <br />MAX SPAN <br />MIN LAG BOLT <br />EMBEDMENT(IN ) <br />2X4 TRUSS <br />24 <br />40 -GIN BETWEEN SUPPORTS <br />, 2-1/2 <br />MOUNTING AND STANDOFF <br />SPECIFICATIONS <br />SINGLE LAYER COMP <br />iRONRIDGE <br />· 72 <br />FLUSH MOUNT <br />, N/A <br />ROOFING MATERIAL <br />RACKING SYSTEM <br />TANDOFF DISTANCE(IN ) <br />MOUNTING TYPE <br />' TILT LEG HEIGHT (IN.): <br />HEIGHT OF PV MODULE <br />ABOVE ROOF SURFACE <br />MAX CANTILEVER (IN)I 24 <br />3" TO 5" <br />ROOF MOUNTED NOTES: <br />-SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED <br />ON RESIDENTIAL STRUCTURE (GROUP R3 BUILDINGS) <br />-THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM <br />THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED <br />-A 36-INCH WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY <br />ESCAPE AND RESCUE OPENING(SI <br />'IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br />GROUNDING ELECTRODE. IT IS ICE CONTRACTOR S RESPONSIBILITY <br />TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE <br />AGOMONAL BUILDING DATA <br />TOTAL ARRAY AREA 150. FT I <br />TOTAL PLAN VIEW ROOF AREA (SQ. FT <br />OCCUPYING PT PERCENTAGE <br />SPRINKLER SYSTEM INSTALLED (IFC 903 3 1 3) <br />374 97 <br />1548 <br />24.22% <br />NO <br />TILT 18' <br />AZIMUTH 273° <br />· <br />ROOF ACCESS POINTS PER <br />2019 CRC R324 (iFC 1204) ' <br />Exceptions. <br />1 These requirements shall not apply to structures designed and <br />constructed in accordance with the International Residential Code <br />2 These requirements shall not g/kr i to roofs with slopes of 2 <br />unRs vertical in 12 units honzontal or less <br />R324 6.1 Pathways <br />R324.6.2 Setback at ridge <br />R324.6 2 1 Alternative setback at ridge <br />· <br />- <br />MINN ELECTRONIC STAMP <br />(N) ENPHASE AC COMBINER BOX 240VAC NEMA 3R ' <br />(N) 30A AC DISCONNECT 2P - NON FUSIBLE <br />(N)125A AC LOAD CENTER <br />NO OTHER LOADS ATTACHED <br />(E) 125A MAIN SERVICE PANEL <br />120/240VAC SINGLE PHASE <br />· — (E) 30A AC DISCONNECT 2P . NON FUSIBLE <br />(E) SOLAREDGE SE3800H.US INVERTER <br />A <br />7 ' EXTERIOR CONDUIT (7/8"-i- ABOVE ROO.) <br />I NEMA 3R JUNCTION BOX <br />TILT 18'' <br />AZIMUTH 188° <br />TX, POINT <br />(E) PV ARRAY <br />3FT FIRE PATHWAY <br />Scale: 3/16" = <br />(For 24x36 Print) <br />0 :2:2,7;238 <br />it5 0.90 0 <br />020000UIre A <br />P <br />L <br />O <br />T <br /> <br />P <br />L <br />A <br />N <br /> <br />Page <br />03 OF 11 <br />801 E Borchard <br />Ave04/13/22