Laserfiche WebLink
RO <br />O <br />F <br />T <br />O <br />P <br />GR <br />O <br />U <br />N <br />D <br /> <br />L <br />EV <br />E <br />L <br /> <br />- <br />HO <br />U <br />S <br />E <br /> E <br />X <br />T <br />E <br />R <br />I <br />O <br />R <br />2 (N) JUNCTION BOX <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE <br />GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH <br />END OF THE EMT CONDUIT WITH THE WIRE THEN FREE <br />AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL <br />11 2 3 4 1 <br />PV CIRCUIT 1: 10 MODULES/PARALLEL [(5) AP SYSTEM DS3-L 2 IN 1] <br />9 10 <br />(N) (10) SOLAREVER SE-166*83-455M-144 (455W) MODULES <br /> WITH AN (5) AP SYSTEMDS3-L <br />ATTACHED TO THE BACK OF EVERY MODULE. <br />M <br />POINT OF <br /> DELIVERY AND <br />INTERCONNECTION <br />20A <br />100A <br />N <br />(E) GROUNDING <br />ELECTRODE OR <br />(UFER) <br />BACKFEED <br />BREAKER <br />EXISTING <br />240V/100A <br />MAIN SERVICE PANEL <br />SINGLE PHASE <br />SHEET <br />CONTRACTOR <br />SOLGEN CONSTRUCTION LLC. <br />815 S VAN NESS AVE <br /> SANTA ANA <br /> CA 92701 <br /> APN:01024404 <br /> DATE:7/16/2022 <br />PORRAS <br />RESIDENCE <br />License#: C-10 1053344 <br />DESIGNER: ONS <br />CORE ENERGY GROUP. <br />ADDRESS: 2072 N MAIN ST <br />FL 2, LOGAN <br />UT 84341-1993 <br />CSLB#: 1053344 <br />E-1 <br />MAIN SERVICE PANEL <br />240/120V 1Ø, 3W <br />MAIN BUSS: 100A <br />MAX BREAKER SIZE: <br />(100A X 1.2) - 100A = 20.0A <br />METER # 222012788641 <br />DESIGN TEMPERATURES <br />ASHRAE EXTREME LOW 2°C <br />ASHRAE 2% HIGH 31 °C <br />PV Module Ratings @ STC <br />Module Make/Model <br />SOLAREVER <br />SE-166*83-455M-144 <br />(455W) MODULE <br />Max Power-Point Current (Imp)10.96A <br />Max Power-Point Voltage (Vmp)41.51 V <br />Open-Circuit Voltage (Voc)49.35V <br />Short-Circuit Current (Isc)11.44A <br />Max Series Fuse (OCPD)20A <br />Nominal Maximum Power at STC (Pmax)455W <br />Maximum System Voltage 1500V <br />Voc Temperature Coefficient -0.29%°C <br />Inverter Ratings <br />Inverter Make/Model AP SYSTEMDS3-L <br />Max DC Volt Rating 60V <br />Peak Output Power 768W <br />Max Nominal Voltage 240V <br />Max AC Current 3.2A <br />Max OCPD Rating 20A <br />SYSTEM SUMMARY <br />BRANCH #1 <br />INVERTERS PER BRANCH 5 <br />MAX AC CURRENT 16A <br />MAX AC OUTPUT POWER 3840W <br />ARRAY STC POWER 4550W <br />ARRAY PTC POWER 4247W <br />MAX AC CURRENT 16A <br />MAX AC POWER 3840W <br />DERATED (CEC) AC POWER 4098.36W <br />Conduit and Conductor Schedule <br />Description Wire <br />Gauge # of Conductors Conduit Type Conduit Size <br />PV WIRES 10 AWG 1 N/A - Free Air N/A - Free Air <br />Bare Copper Ground (EGC/GEC) 6 AWG 1 N/A - Free Air N/A - Free Air <br />THWN-2 10 AWG 2 EMT 3/4" <br />THWN-2 - Ground 8 AWG 1 EMT 3/4" <br />815 S Van Ness <br />Ave12/30/22