Laserfiche WebLink
N <br />3' <br />3' <br />3' <br />3' <br />SCALE: 1/8" = 1'-0" <br />PV SYSTEM SITE PLAN <br />PV SYSTEM SIZE: <br />4.55 kW DC <br /> LEGEND <br />M METER MAIN COMBO <br />CONSTRUCTION NOTES <br />M <br />PV INTERCONNECTION POINT. <br />LOCATION OF METER MAIN COMBO MOUNTED ON <br />EXTERIOR WALL OF A SINGLE FAMILY RESIDENCE. <br />LOCATION OF "RAPID SHUTDOWN" <br />DISCONNECT NEC 690.12 <br />NEW SOLAR PANELS <br />DRIVEWAY <br />(10) SOLAREVER SE-166*83-455M-144 (455W) <br />WITH (5) AP SYSTEMDS3-L MOUNTED TO <br />THE BACK OF EACH MODULE MOUNTED ON <br />FLAT ROLLED SHINGLE ROOF <br /> 815 S VAN NESS AVE <br />ROOF OBSTRUCTIONS <br />SHEET <br />CONTRACTOR <br />SOLGEN CONSTRUCTION LLC. <br />815 S VAN NESS AVE, <br /> SANTA ANA, <br /> CA 92701 <br /> APN:01024404 <br /> DATE:7/16/2022 <br />PORRAS <br />RESIDENCE <br />License#: C-10 1053344 <br />DESIGNER: ONS <br />CORE ENERGY GROUP. <br />ADDRESS: 2072 N MAIN ST <br />FL 2, LOGAN <br />UT 84341-1993 <br />CSLB#: 1053344 <br />PV-1 <br />1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON <br />RESIDENTIAL STRUCTURE. <br />2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE <br />WITH THE CBC SECTION 1609 TO WITHSTAND A BASIC <br />WIND SPEED OF 95 MPH (3 SECOND GUST), WIND <br />EXPOSURE B. <br />3. THE ROOF MEMBERS ARE 2 "X 4" TRUSSES AT 24" ON <br />CENTER. CONNECTION TO STRUCTURE SHALL NOT BE <br />WITHIN 11" OF NAILING PLATES. <br />4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT <br />OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING <br />ROOF VENTS. <br />5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF <br />SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE <br />(INCLUDING CABLES UNDERNEATH MODULES AND <br />RACKING). <br />6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE <br />FOLLOWING (CRC R324.7.1, CBC 3111.2.1) <br />6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT <br />OF GROUND LADDERS OVER OPENINGS SUCH AS <br />DOORS OR WINDOWS. <br />6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION IN <br />LOCATIONS WHERE ACCESS POINT DOES NOT <br />CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH <br />AS: TREES, WIRES, OR SIGNS. <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />Roof Azimuth: 90° <br />Roof Tilt: 3° <br />Roof Section 1 <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />IN <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />NE <br />(E)STRUCTURE ON PROPERTY <br />Structural <br />Only <br />The scope of the plans is for the installation of the solar photovoltaic system only and the approval is <br />subject to compliance with all applicable city and state codes and regulations regarding construction. The <br />approval of the plans does not constitute any certification of the accuracy, completeness, or building <br />permit status of the existing buildings and structures as shown. <br />Bldg# 101113302 <br />Elec# 20177860 <br />Issued 12/29/22 <br />815 S Van Ness Ave <br />12/30/22