My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
900 S Deming St - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Deming St
>
900 S Deming St
>
900 S Deming St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 5:13:10 PM
Creation date
5/30/2025 8:01:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20177844
101112626
Full Address
900 S Deming St
Document Relationships
101112626 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Deming St\900 S Deming St
20177844 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Deming St\900 S Deming St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
97% <br />0.97 <br />1.21 <br />1.21 <br />8 IQ8PLUS-72-2-US (CEC) <br />FROM JBOX TO IQ COMBINER BOX <br />FROM IQ COMBINER BOX TO PV LOAD CENTER <br />1 1/2'' <br /> TEMP. DERATE FACTOR (TEMP - 39 + 22 = 61C)0.58 <br /> RACEWAY HEIGHT FROM ROOF <br />PV SYSTEM <br />AS INDICATED <br />SEPTEMBER 29, 2022 <br />GREGORIO BEJINES <br />900 SOUTH DEMING ST <br />SANTA ANA, CA 92704 <br />Current Insight, LLC <br />2852 W. Amini Way <br />South Jordan, UT <br />84095 <br />EXO ENERGY <br />Address: <br />1247 Simpson Way <br />Escondido, CA 92029 <br />Phone Number: <br />208-351-4153 <br />CSLB:#1063308 <br />Drafted By: <br />CONTRACTOR <br />3 <br />WIRE SIZE <br />CALCULATIONSFROM PV MODULES TO JBOX <br /> #12 AWG Q-CABLE, PV WIRE(2) 1 <br />(1) #6 AWG BARE CU EGC <br />2 <br /> #8 AWG CU EGC, <br />(3) <br />3 <br />(1) #8 AWG CU EGC, <br /> MAXIMUM INVERTER OUTPUT CURRENT <br /> WALL TEMPERATURE FACTOR <br />OUTPUT CALCULATIONS <br />PV SYSTEM MAX DC OUTPUT <br />PV SYSTEM MAX AC OUTPUT <br />1.25 <br />0.91 <br />(2) <br />(1) <br />8 <br /> Pmax (PTC Rating) <br />3/4'' EMT TYPE CONDUIT <br />3/4'' EMT TYPE CONDUIT <br />#10 AWG THWN-2 <br />WIRE CHART WIRE CHART <br />1 <br />NUMBER OF SERIES IN BRANCH CIRCUIT <br /> BRANCH CIRCUITS <br /> INVERTER OUTPUT MAX CURRENT <br /> COEFFICIENT 1.25 <br /> BRANCH CIRCUIT CURRENT: 8 BREAKER SIZE PER BRANCH CRCT <br />20A <br />ADJST. FACTOR (1 thru 3 WIRES)1.0 <br />**1.258 1.21 12.1A <br /> ADJUSTED CONDUCTOR AMPACITY <br />/ / 12.1 0.58 1.0 20.9A <br /> NUMBER OF MICROINVERTERS <br /> 3.20KW <br />2.88KW <br />MAIN SERVICE PANEL RATING <br />BUSBAR RATING <br />MAIN BREAKER <br />PV BACKFEED BREAKER SIZE <br />120% RULE: <br />MAX ALLOWED FEED <br />40A <br />200A <br />200A <br />240A <br />200A''MB'' + 40A "SOLAR" = 240A ≤ 240A MAX <br />WIRE CHART <br />QTY <br /> CONSIDER CONTINUOUS COEFFICIENT <br /> CONSIDER CONTINUOUS (A)1.25**8 1.21 12.1 <br />*1.25 / 0.91*8 1.21 13.3 <br /> #10 AWG THWN-2 <br /> TEMPERATURE ADJUSTMENT (A) <br />8 <br />Attention!!!!!!! <br />Need Calculation <br />(don't delete this note) <br />8 <br />8 <br />400W <br />* 400 <br />371.5W <br />* 371.5 * <br />Q.PEAK DUO BLK ML-G10+ 400 <br />8 <br />(3) <br />4 <br />(1) #8 AWG CU EGC, <br /> WALL TEMPERATURE FACTOR <br />3/4'' EMT TYPE CONDUIT <br />MAXIMUM INVERTER OUTPUT CURRENT <br /> CONSIDER CONTINUOUS (A) <br /> #8 AWG THWN-2 <br /> TEMPERATURE ADJUSTMENT (A) <br />0.91 <br />(N)9.68+(E)15.0=24.68 <br />30.9 <br />33.9 <br />24.68 * 1.25 <br />24.68 * 1.25 / 0.91 <br />1.25 CONSIDER CONTINUOUS COEFFICIENT <br />FROM PV LOAD CENTER TO MAIN SERVICE PANEL <br />900 S Deming St <br />11/09/22
The URL can be used to link to this page
Your browser does not support the video tag.