Laserfiche WebLink
SOLARMOUNT Flush Product Assumptions <br />Limitations of Responsibility: It is the user’s responsibility to ensure that inputs are correct for your specific project. <br />Unirac is not the solar, electrical, or building engineer of record and is not responsible for the solar, electrical, or <br />building design for this project. <br />Allowable spans and resulting point loads are subject to the following conditions: <br />1. Building Height ≤ 60 ft unless otherwise specified. <br />2. Roof Slope ≥ 1.2° <br />3. Maximum rail cantilever ≤ 1/3 of selected span. <br />4. Occupancy/Risk Category = II unless otherwise specifi ed. <br />5. ASCE 7-05: Basic Wind Speed: 85-170 mph (IBC 2006/ASCE 7-05). Wind Exposure: B, C or D. <br />6. ASCE 7-10: Basic Wind Speed: 95-190 mph (IBC 2012/ASCE 7-10). Wind Exposure: B, C or D. <br />7. ASCE 7-16: Basic Wind Speed: 85-190 mph (IBC 2018/ASCE 7-16). Wind Exposure: B, C or D. <br />8. Ground Snow Load: 0-100 psf. (Reduction can be input if this is acceptable with your local building authority). Results are based on <br />uniform snow loading and do not consider unbalanced, drifting, and sliding conditions. <br />9. Dead Load ≤ 5 psf (includes PV Modules and Racking). <br />10. Maximum PV Module Length: 85 in. <br />11. Seismic: Installations must be in seismic site class A, B, C, or D as defined in IBC 2006/ASCE 7-05. <br />12. Intermediary Span Distances: Roof attachment point loads be reduced linearly if the installed distance between the attachments is less <br />than the selected span. For example, if the spacing is half the amount shown in the results, then the point loads may also be reduced by <br />half. <br />13. Spans greater than 96 in.: While our products are valid for greater spans in many instances, we do not recommend this mounting <br />configuration. Typical residential roofs are not designed for the larger point loads that might result from such excessive spans and we <br />recommend final design by a licensed professional engineer of responsible charge. <br />Pitched Roof Solutions (Flush Mounted Solutions): <br />Modules are parallel to the roof surface and within 10 in. of it. <br />Allowable roof pitch: 1.2°-45°. (SM is not fire tested for sloped of < 2:12, please check with your AHJ if this is acceptable.) <br />Building has a monoslope roof with a slope ≤ 3°, a gable roof ≤ 45°, or a hip roof ≤ 27°. <br />901 N Westwood <br />Ave - <br />101111905-201773 <br />06 <br />03/29/23