Laserfiche WebLink
ENGINEERING REPORT <br />* Distributed Dead Load 2.77 psf <br />* Average Roof Point Dead Load 16.33 lbs <br />92703 <br />Plan review <br />TOTAL NUMBER OF MODULES 9 <br />TOTAL KW 2.97 KW <br />TOTAL MODULE AREA ~165 ft <br />Loads Used for Design <br />BUILDING CODE ASCE 7-16 <br />BASIC WIND SPEED 100.00 mph <br />GROUND SNOW LOAD 0.00 psf <br />SEISMIC (SS)1.462 <br />ELEVATION 81.00 ft <br />WIND EXPOSURE B <br />TOPOGRAPHICAL FACTOR KZT 1.00 <br />VELOCITY PRESSURE, QZ 15.20 psf <br />Loads Determined by Zip <br />CITY, STATE Santa Ana, CA <br />BASIC WIND SPEED 89.00 mph <br />GROUND SNOW LOAD 0.00 psf <br />2 <br />Inspection <br />PRODUCT SOLARMOUNT FLUSH <br />MODULE MANUFACTURER Trina Solar <br />MODEL 9 - TSM-DD06M.05(II) 330 <br />MODULE WATTS 330 watts <br />MODULE LENGTH 66.85" <br />MODULE WIDTH 39.53" <br />MODULE THICKNESS 1.38" <br />MODULE WEIGHT 41.20 lbs <br />EXPANSION JOINTS Every 40' <br />RAILS DIRECTION CROSS-SLOPE <br />BUILDING HEIGHT 30.00 ft <br />ROOF TYPE Other <br />RAFTER SPACING 24.00" <br />* TOTAL WEIGHT 457.32 lbs <br />MID CLAMP Universal AF Clamp <br />END CLAMP Universal AF Clamp <br />* Calculated based on suggested quantity given on part list. <br />901 N Westwood <br />Ave - <br />101111905-201773 <br />06 <br />03/29/23