Laserfiche WebLink
_IGALVANIZED 21/2'x 12'x 7 GAGE THICK <br /> STEEL STRAP W/4-5/8'0 LAGS <br />.1 4- <br />12• <br />IT31/2* <br />2'-00 <br />/ /44 BE <br />4'*4' I <br />POST-- <br />4'x4" POST MINIMUM <br />- APPROVED CAP <br />\ /ift <br />L /-8D NAILS, <br />-/ EACH END <br /> ,/1 4'x BEAM - <br />-494°KNEE * <br />BRACE N <br />I2-1/2' 0 x 9 LONG LAGS SCREWS / -,1'xe KNEE . <br />NEACH END .·BRACE <br />1(SEE DETAIL 'E') <br />DETAIL "B" ' DETAIL "B" ALTERNATE <br />STANDOFF 1-1 - <br />ISTAND-OFF -1' STAND-OFF <br />A POST/ |BASE - <br />12' --=4:x.BEAM. <br />ANCHOR L --r '. , '+ +1 <br />EMBEDI <br />ANCHORS IN 1- <br />CONCRETEI <br />I hkil / <br />14- 12' <br />BOLT <br />31/2' <br />\ IGALVANIZED <br />L-I12'x12'x7 GAGE <br />IT W/6-5/8' 0 LAGS <br />\0 :3*iiI 4GRADE \-/i <br />DETAIL "C" <br />- 4.x pOST <br />DETAIL "D" <br />NOTES: <br />ALL MATERIALS: LUMBER, HARDWARE, PLYWOOD, ROOFING, ETC. SHALL BE NEW <br />AND BEAR MANUFACTURER'S OR CERTIFIED AGENCY'S GRADE MARK. <br />ALL CONSTRUCTION SHALL CONFORM TO THE CALIFORNIA BUILDING <br />CODE CURRENTLY IN EFFECT. <br />CONCRETE SLAB TO BE MINIMUM 31/2" THICK. <br />POSTS SHALL BE MINIMUM 4'x4°. <br />BOTTOM OF POSTS SHALL BE ONE INCH (1') ABOVE SLAB. <br />ROOF SHEATING SHALL BE: <br />a. 1/2" PLYWOOD, CDX, 5 PLY EXTERIOR GLUE, WITH INDEX 32/16, T&G <br />STRUCTURAL I, WITH 10 d AT 6" O/C AT SUPPORTED ENDS, AND12" O/CALONG _ <br />INTERMEDIATE FRAMING MEMBERS, OR <br />b. 1" BOARD SPAN 32% 2' SOLID T&G SPAN 8'-0% 2%<2° SELF-SPACED SPAN 6'-0". <br />ROOFING SHALL BE MIN. CLASS °C' ROOF COVERING (CBC TABLE 1505.1) OF: <br />a. WOOD SHAKES: 4/12 PITCH <br />b. WOOD SHINGLES: 3/12 PITCH <br />c. BUILT-UP ROOF SLOPE TO DRAIN (MINIMUM 1/4°/FT.) <br />d. CLAY AND CONCRETE ROOF TILES INSTALLED IN ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS. <br />MAXIMUM HEIGHT FOR A PATIO COVER IS TWELVE FEET. <br />PATIO COVER SHALL BE USED ONLY FOR RECREATIONAL OUTDOOR LIVING · <br />PURPOSE AND NOT AS CARPORT, GARAGE, STORAGE ROOM OR HABITABLE ROOM. <br />1. ENCLOSURE WALLS MAY HAVE ANY CONFIGURATION, PROVIDED THE OPEN AREA <br />OF THE LONGER WALL AND ONE ADDITIONAL WALL IS. EQUALTO AT LEAST SIXTY- <br />FIVE PERCENT OF THE AREA BELOW A MINIMUM OF 6'-8" OF EACH WALL, <br />MEASURED FROM THE FLOOR. <br />. OPENINGS MAY BE ENCLOSED WITH INSECT SCREENING OR PLASTIC THAT IS <br />READILY REMOVABLE, TRANSLUCENT, OR TRANSPARENT PLASTIC NOT MORE THAN <br />1/8 INCH IN THICKNESS. <br />L EMERGENCY EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS MAY OPEN <br />INTO AN AREA OF AN UNENCLOSED PATIO COVER. <br />1. PAnO COVER MUST BE AT LEAST 5 FEET FROM PROPERTY LINES. <br />-4- <br />- 4'x4' KNEE BRACE C- <br />r 2-1/2' 0 € LONG LAG SCREWS <br />-0-0- <br />1-T <br />E- 4°x POST <br />DETAIL "E" <br />PERSON RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF PATIO COVER: <br />U/£.Uet_ U f LuE€;, A-5 <br />PRINT NAME <br />2 < 0 f//4-2-I <br />SIGNATURE / <br />9/14,3 <br />DATE <br />rev: 07/1 9/2011 Page 2 of 2 <br />li