My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1003 W Richland Ave Units 18, 19, 20 & 21 - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Richland Ave
>
1003 W Richland Ave Unit# 18
>
1003 W Richland Ave Units 18, 19, 20 & 21 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:52:23 AM
Creation date
6/1/2025 11:52:13 AM
Metadata
Fields
Template:
Plan
Permit Number
101117246
101117255
101117256
101117257
Full Address
1003 W Richland Ave Unit# 18
1003 W Richland Ave Unit# 19
1003 W Richland Ave Unit# 20
1003 W Richland Ave Unit# 21
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E <br />Project Name:1003 W RICHLAND AVE Calculation Date/Time:2023-10-02T23:55:30-07:00 (Page 7 of 9) <br />Calculation Description:Title 24 Analysis Input File Name:Building1.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2023-10-02 23:55:37 <br />WATER HEATERS <br />01 02 03 04 05 06 07 08 09 10 11 12 13 <br />Name <br />Heating <br />Element <br />Type <br />Tank Type # of Units Tank Vol. <br />(gal) <br />Heating <br />Efficiency <br />Type <br />Efficiency Rated Input <br />Type <br />Input Rating <br />or Pilot <br />Tank <br />Insulation <br />R-value <br />(Int/Ext) <br />Standby Loss <br />or Recovery <br />Eff <br />1st Hr. Rating <br />or Flow Rate <br />Tank <br />Location <br />DHW <br />Heater 1 Gas <br />Consumer <br />Instantaneo <br />us <br />1 0 UEF 0.81 Btu/Hr 200000 0 n/a <br />WATER HEATING - HERS VERIFICATION <br />01 02 03 04 05 06 07 <br />Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution <br />Type Recirculation Control Shower Drain Water Heat <br />Recovery <br />DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required <br />SPACE CONDITIONING SYSTEMS <br />01 02 03 04 05 06 07 08 09 <br />Name System Type Heating Unit Name Heating Equipment <br />Count Cooling Unit Name Cooling Equipment <br />Count Fan Name Distribution Name Required <br />Thermostat Type <br />HVAC1 Heat pump <br />heating cooling <br />Heat Pump System <br />1 1 Heat Pump System <br />1 1 n/a n/a Setback <br />423-P010179572A-000-000-0000000-0000 10/03/2023 00:05 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E <br />Project Name:1003 W RICHLAND AVE Calculation Date/Time:2023-10-02T23:55:30-07:00 (Page 8 of 9) <br />Calculation Description:Title 24 Analysis Input File Name:Building1.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2023-10-02 23:55:37 <br />HVAC - HEAT PUMPS <br />01 02 03 04 05 06 07 08 09 10 11 12 13 <br />Name System Type Number of <br />Units <br />Heating Cooling <br />Zonally <br />Controlled <br />Compressor <br />Type HERS VerificationEfficiency <br />Type <br />HSPF / <br />HSPF2 / <br />COP <br />Cap 47 Cap 17 Efficiency <br />Type <br />SEER / <br />SEER2 <br />EER / <br />EER / <br />CEER <br />Heat Pump <br />System 1 VCHP-ductless 1 HSPF2 9.5 12000 11400 EER2SEER2 16 12.5 Not Zonal Single <br />Speed <br />Heat Pump System <br />1-hers-htpump <br />HVAC HEAT PUMPS - HERS VERIFICATION <br />01 02 03 04 05 06 07 08 09 <br />Name Verified Airflow Airflow Target Verified EER/EER2 Verified <br />SEER/SEER2 <br />Verified Refrigerant <br />Charge <br />Verified <br />HSPF/HSPF2 <br />Verified Heating <br />Cap 47 <br />Verified Heating <br />Cap 17 <br />Heat Pump System <br />1-hers-htpump Not Required 0 Not Required Not Required Yes No Yes Yes <br />VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION <br />01 02 03 04 05 06 07 08 09 10 <br />Name <br />Certified <br />Low-Static <br />VCHP System <br />Airflow to <br />Habitable <br />Rooms <br />Ductless Units <br />in Conditioned <br />Space <br />Wall Mount <br />Thermostat <br />Air Filter Sizing <br />& Pressure <br />Drop Rating <br />Low Leakage <br />Ducts in <br />Conditioned <br />Space <br />Minimum <br />Airflow per <br />RA3.3 and <br />SC3.3.3.4.1 <br />Certified <br />non-continuous <br />Fan <br />Indoor Fan not <br />Running <br />Continuously <br />Heat Pump System 1 Not required Required Required Required Not required Not required Not required Not required Not required <br />INDOOR AIR QUALITY (IAQ) FANS <br />01 02 03 04 05 06 07 08 09 <br />Dwelling Unit Airflow (CFM)Fan Efficacy <br />(W/CFM)IAQ Fan Type <br />Includes <br />Heat/Energy <br />Recovery? <br />IAQ Recovery <br />Effectiveness - SRE <br />Includes Fault <br />Indicator Display?HERS Verification Status <br />SFam ADU <br />IAQVentRpt 29 0.35 Exhaust No n/a No Yes <br />423-P010179572A-000-000-0000000-0000 10/03/2023 00:05 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E <br />Project Name:1003 W RICHLAND AVE Calculation Date/Time:2023-10-02T23:55:30-07:00 (Page 9 of 9) <br />Calculation Description:Title 24 Analysis Input File Name:Building1.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2023-10-02 23:55:37 <br />DOCUMENTATION AUTHOR'S DECLARATION STATEMENT <br />1. I certify that this Certificate of Compliance documentation is accurate and complete. <br />Documentation Author Name:Documentation Author Signature: <br />Company:Signature Date: <br />Address:CEA/ HERS Certification Identification (If applicable): <br />City/State/Zip:Phone: <br />RESPONSIBLE PERSON'S DECLARATION STATEMENT <br />I certify the following under penalty of perjury, under the laws of the State of California: <br />1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. <br />2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. <br />3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, <br />calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. <br />Responsible Designer Name:Responsible Designer Signature: <br />Company:Date Signed: <br />Address:License: <br />City/State/Zip:Phone: <br /> <br />Anush Dagesyan <br />HERS RATERS, LLC 10/03/2023 <br />1233 RUBERTA AVE <br />GLENDALE, CA 91201 855-437-7787 <br />Anush Dagesyan <br />HERS RATERS, LLC 10/03/2023 <br />1233 RUBERTA AVE 1016232 <br />GLENDALE, CA 91201 855-437-7787 <br />423-P010179572A-000-000-0000000-0000 10/03/2023 00:05 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of <br />this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. <br />1003 W Richland Ave Units 18, <br />19, 20 & 21 - 101117246 & <br />7255-576/19/2024
The URL can be used to link to this page
Your browser does not support the video tag.