My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1003 W Richland Ave Units 18, 19, 20 & 21 - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Richland Ave
>
1003 W Richland Ave Unit# 18
>
1003 W Richland Ave Units 18, 19, 20 & 21 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:52:23 AM
Creation date
6/1/2025 11:52:13 AM
Metadata
Fields
Template:
Plan
Permit Number
101117246
101117255
101117256
101117257
Full Address
1003 W Richland Ave Unit# 18
1003 W Richland Ave Unit# 19
1003 W Richland Ave Unit# 20
1003 W Richland Ave Unit# 21
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1/16/2024 <br />11 <br />Mu <br />l <br />t <br />i <br />- <br />F <br />a <br />m <br />i <br />l <br />y <br /> <br />D <br />w <br />e <br />l <br />l <br />i <br />n <br />g <br />AD <br />U <br /> <br />G <br />a <br />r <br />a <br />g <br />e <br />/ <br />P <br />a <br />r <br />k <br />i <br />n <br />g <br /> <br />C <br />o <br />n <br />v <br />e <br />r <br />s <br />i <br />o <br />n <br />10 <br />0 <br />3 <br /> <br />W <br />. <br /> <br />R <br />i <br />c <br />h <br />l <br />a <br />n <br />d <br /> <br />A <br />v <br />e <br />. <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />DR <br />A <br />F <br />T <br />I <br />N <br />G <br /> <br />& <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br /> <br />S <br />E <br />R <br />V <br />I <br />C <br />E <br />S <br />, <br /> <br />L <br />L <br />C <br />Sheet:of6 <br />KT <br />A <br /> <br />D <br />R <br />A <br />F <br />T <br />I <br />N <br />G <br /> <br />& <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br /> <br />S <br />E <br />R <br />V <br />I <br />C <br />E <br />S <br />, <br /> <br />L <br />L <br />C <br />22 <br />2 <br /> <br />W <br />. <br /> <br />6 <br />T <br />H <br /> <br />S <br />T <br />, <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />4 <br />0 <br />0 <br /> <br />| S <br />A <br />N <br /> <br />P <br />E <br />D <br />R <br />O <br />, <br /> <br />C <br />A <br /> <br />9 <br />0 <br />7 <br />3 <br />1 <br />E: <br /> i <br />n <br />f <br />o <br />@ <br />k <br />t <br />a <br />d <br />r <br />a <br />f <br />t <br />i <br />n <br />g <br />. <br />c <br />o <br />m <br /> <br />| <br />T <br />: <br /> <br />(3 <br />1 <br />0 <br />) <br />- <br />9 <br />4 <br />0 <br />- <br />9 <br />0 <br />2 <br />2 <br />ww <br />w <br />. <br />k <br />t <br />a <br />d <br />r <br />a <br />f <br />t <br />i <br />n <br />g <br />. <br />c <br />o <br />m <br />Date: <br />A-6 <br />Proposed <br />Electrical Layout <br />ELECTRICAL LEGEND: <br />DUPLEX RECEPTACLE WITH ARC <br />FAULT INTERRUPTER <br />GFCI <br />S <br />DUPLEX RECEPTACLE WITH <br />GROUND FAULT INTERRUPTER <br />SINGLE POLE SWITCH <br />S 3-WAY SWITCH <br />3 <br />CEILING LIGHT FIXTURE <br />EXHAUST FAN <br />(Exhaust fans shall be 50 CFM <br />minimum, ENERGY STAR <br />compliant and be ducted to <br />terminate outside the building. <br />Exhaust fans must be <br />controlled by a humidity <br />control.) <br />ELECTRICAL WIRING <br />S SINGLE POLE SWITCH WITH <br />VACANCY SENSOR <br />S 3-WAY SWITCH WITH <br />VACANCY SENSOR3 vc <br />vc <br />WALL LIGHT FIXTURE <br />PROPOSED ELECTRICAL PLAN (AREA 1 - UNITS 20 & 21) <br />SCALE: 1" = 4' <br />NOTE: PLUMBING WALLS SHALL BE <br />CONSTRUCTED OF 2x6 STUDS @ 16" O.C. <br />LEGEND: <br />NEW WALL <br />(2"X4" STUDS @ 16" O.C., <br />UNLESS NOTED OTHERWISE) <br />EXISTING WALL---CMSMOKE <br />DETECTOR <br />CARBON <br />MONOXIDE <br />DETECTOR <br />--SDWALL TO BE DEMOLISH <br />PROPOSED ELECTRICAL PLAN (AREA 2 - UNITS 18 & 19) <br />SCALE: 1" = 4' <br />NOTE: PRIOR TO INSTALLATION OF LIGHT <br />FIXTURES, SWITCHES AND OUTLETS, <br />CONTRACTOR SHALL VERIFY LOCATIONS <br />WITH OWNER. <br />GF <br />C <br />I <br />GFCIGF <br />C <br />I <br />GF <br />C <br />I <br />S <br />S <br />S <br />SSS <br />S <br />CM SD <br />SD <br />vc <br />GF <br />C <br />I <br />GFCI GF <br />C <br />I <br />GF <br />C <br />I <br />S <br />S <br />S <br />SSS <br />S <br />CMSD <br />SD <br />vc <br />GF <br />C <br />I <br />GFCIGF <br />C <br />I <br />GF <br />C <br />I <br />SD <br />CM SD <br />SSS <br />vc <br />S S <br />S <br />S <br />GF <br />C <br />I <br />GFCI GF <br />C <br />I <br />GF <br />C <br />I <br />SD <br />CMSD <br />SSS <br />vc <br />SS <br />S <br />S <br />ELECTRICAL: <br />1.Access and working space shall be provided and maintained about all electrical equipment <br />to permit ready and safe operation and maintenance of such equipment. (CEC 110.26) <br />2.Electrical panels are not allowed to be located in bathrooms or clothes closets. (CEC <br />240.24(D) & (E)) <br />3.Ground fault circuit interrupter (GFCI) protection shall be provided at all receptacle outlets <br />in bathrooms, garages, outdoor areas, crawl spaces, basements, kitchens where the <br />receptacles are installed to serve the countertop surfaces, sinks where receptacles are <br />installed within 6 feet from the top inside edge of the bowl of the sink, boathouses, laundry <br />areas. (CEC 210.8) <br />4.For one-and two-family dwellings, and multifamily dwellings, at least one receptacle outlet <br />shall be installed in areas specified in 210.52(G)(1) through (G)(3). These receptacles <br />shall be in addition to receptacles required for specific equipment. (CEC 210.52(G)) <br />(1) Garages. In each attached garage and in each detached garage with electrical <br />power, at least one receptacle outlet shall be installed in each vehicle bay and not <br />more than 5-1/2 feet above the floor. (CEC 210.52(G)(1)) <br />EXCEPTION: Garages spaces not attached to an individual dwelling unit of a <br />multifamily dwelling shall not require a receptacle outlet in each vehicle bay. <br /> (2) Accessory Buildings. In each accessory building with electric power. <br />(CEC 210.52(G)(2)) <br />(3) Basements. In each separate unfinished portion of a basement. <br />(CEC 210.52(G)(3)) <br />5.Combination type Arc Fault Circuit Interrupter (AFCI) circuit breakers are required for all <br />120V single phase 15A/20A branch circuits. Except where GFCI circuits are provided. <br />(CEC 210.12(A)) <br />6.Kitchen countertops 12 inches or wider must have receptacle outlets installed so no point <br />along the counter wall is more than 24 inches from a receptacle. (CEC 210.52(C)) <br />7.Kitchen island and peninsular countertops shall have at least one receptacle outlet. At <br />least one receptacle outlet shall be located within 2 feet of the outer end of a peninsular <br />countertop or work surface. Receptacle outlets shall be located below countertop or works <br />surfaces: Not more than 12 inches below the countertop or work surface. Receptacles <br />installed below a countertop or work surface shall not be located where the countertop or <br />work surface extends more than 6 inches beyond its support base. (CEC 210.52(C)) <br />8.A minimum of one dedicated 20 ampere circuit is required for each bathroom and laundry <br />room. (CEC 210.11(C)(2)&(3)) <br />9.In bathrooms, a GFCI protected receptacle outlet is required within 3 feet of the edge of <br />each sink. (CEC 210.52(D)) <br />10.Receptacles shall not be installed within a zone measured 3 feet horizontally and 8 feet <br />vertically from the top of the bathtub rim or shower stall threshold. The identified zone is <br />all-encompassing and shall include the space directly over the tub or shower stall. (CEC <br />406.9(C)) <br />EXCEPTION: In bathrooms with less than the required zone the receptacles(s) shall <br />be permitted to be installed opposite the bathtub rim or shower stall threshold on the <br />farthest wall within the room. <br />11.Receptacles shall be installed such that no point measured horizontally along the floor line <br />of any wall space is more than 6 feet from a receptacle outlet. (CEC 210.52(A)(1)) <br />12.In dwelling units, hallways of 10 feet or more in length shall have at least one receptacle <br />outlet. (CEC 210.52(H)) <br />13.Contractor shall verify the exact location of the lighting, switches, receptacles, exhaust <br />fans and ceiling fans with the owner before installation. <br />No part of this plan set may be changed, reproduced or distributed in any form or by any means, without the prior written permission of KTA DRAFTING & DESIGN SERVICES, LLC. <br />NOTE: ENERGY RELATED ITEMS AND <br />APPLIANCES SHALL BE INSTALLED PER <br />TITLE 24 REPORT AND OWNER. <br />(N) KITCHEN HOOD <br />(MIN. 100 CFM) <br />(N) KITCHEN HOOD <br />(MIN. 100 CFM) <br />(N) KITCHEN HOOD <br />(MIN. 100 CFM) <br />(N) KITCHEN HOOD <br />(MIN. 100 CFM) <br />Electric Ready Notes <br />1. Water Heating system (water heater) (Section 150.0(n)) <br />A. Systems using gas or propane water heaters to serve individual dwelling units shall designate a space at least 2.5 <br />feet by 2.5 feet wide and 7 feet tall suitable for the future installation of a heat pump water heater (HPWH) by meeting <br />either A or B listed under Section 150.0(n). <br />i. If the designated space is within 3 feet from the water heater: <br />a. A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 <br />conductor, 10 AWG copper branch circuit, within 3 feet from the water heater. <br />ii. Isolate both ends of the unused conductor. <br />b. A reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker. <br />c. A condensate drain that allows natural draining of the water heater. <br />d. If the designated space is more than 3 feet from the water heater: see additional Code requirements. <br />B. When a second water heater is installed as part of the addition shall comply with Section (150.2(a)(D). <br />1003 W Richland Ave Units 18, <br />19, 20 & 21 - 101117246 & <br />7255-576/19/2024
The URL can be used to link to this page
Your browser does not support the video tag.