Laserfiche WebLink
SCALE: N.T.S. <br />N <br />PROJECT <br />LOCATION <br />CO <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br /> <br />© <br /> <br />W <br />A <br />N <br />G <br />T <br />A <br />S <br />T <br />I <br />C <br /> <br />A <br />R <br />C <br />H <br />D <br />E <br />I <br />S <br />G <br />N <br /> <br />L <br />L <br />C <br /> <br /> 2 <br />0 <br />2 <br />3 <br />G E N E R A L N O T E S A B B R E V I A T I O N S <br />G E N E R A L S Y M B O L S <br />V I C I N I T Y M A P <br />A.B. <br />ABV <br />AC <br />A/C <br />A.D. <br />ADD <br />ADJ <br />ADJA <br />AFF <br />AGGR. <br />AL <br />ALT <br />ANCH <br />ANOD <br />APPROX <br />ARCH <br />ASPH <br />AUTO <br />AVG <br />BBD <br />BD <br />BLDG <br />BLK <br />BLKG <br />BLW <br />BM <br />BOT <br />B.O.B. <br />B.O.C. <br />B.O.F. <br />B.O.S. <br />B.O.W. <br />BRZWY <br />BS <br />BTWN <br />B.U.R. <br />BW <br />CAB <br />C.B. <br />CEM <br />CER <br />CF <br />CI <br />C.I.P. <br />C.J. <br />CLG <br />CLKG <br />CLO <br />CLR <br />CM <br />CMU <br />CNTR <br />CO <br />COL <br />CONC <br />COND <br />CONN <br />CONSTR <br />CONT <br />CONTR <br />CORR <br />CPT <br />CRS <br />CS.J. <br />CTR <br />CTSK <br />D <br />DA <br />DBL <br />DEPT <br />D.F. <br />DIA <br />DIM <br />DISP <br />DN <br />DR <br />DS <br />DSP <br />DTL <br />DWG <br />DWR <br />E <br />EA <br />EF <br />EIFS <br />ELEC <br />ELEV <br />EP <br />ENCL <br />EMER <br />EQ <br />EQPT <br />EST <br />ANCHOR BOLT <br />ABOVE <br />ACOUSTICAL <br />AIR CONDITIONER (ING) <br />AREA DRAIN <br />ADDENDUM <br />ADJUSTABLE <br />ADJACENT <br />ABOVE FINISHED FLOOR <br />AGGREGATE <br />ALUMINUM <br />ALTERNATE <br />ANCHOR, ANCHORED <br />ANODIZED <br />APPROXIMATE <br />ARCHITECTURAL <br />ASPHALT <br />AUTOMATIC <br />AVERAGE <br />BULLETIN BOARD <br />BOARD <br />BUILDING <br />BLOCK <br />BLOCKING <br />BELOW <br />BEAM <br />BOTTOM <br />BOTTOM OF BEAM <br />BOTTOM OF CONCRETE <br />BOTTOM OF FOOTING <br />BOTTOM OF STEEL <br />BOTTOM OF WALL <br />BREEZEWAY <br />BOTH SIDES <br />BETWEEN <br />BUILT-UP ROOFING <br />BOTH WAYS <br />CABINET <br />CATCH BASIN <br />CEMENT <br />CERAMIC <br />CUBIC FOOT <br />CAST IRON <br />CAST-IN-PLACE <br />CONTROL JOINT <br />CEILING <br />CAULKING <br />CLOSET <br />CLEAR <br />CHANGE OF MATERIAL <br />CONCRETE MASONRY UNIT <br />COUNTER <br />CLEAN-OUT <br />COLUMN <br />CONCRETE <br />CONDITION <br />CONNECT(ED), CONNECTION <br />CONSTRUCTION <br />CONTINUOUS <br />CONTRACTOR <br />CORRIDOR <br />CARPET <br />COURSE <br />CONSTRUCTION JOINT <br />CENTER <br />COUNTERSINK <br />DEEP, DEPTH <br />DOUBLE ACTING <br />DOUBLE <br />DEPARTMENT <br />DRINKING FOUNTAIN <br />DIAMETER <br />DIMENSION <br />DISPENSER <br />DOWN <br />DOOR <br />DOWNSPOUT <br />DRY STANDPIPE <br />DETAIL <br />DRAWING <br />DRAWER <br />EAST <br />EACH <br />EACH FACE <br />EXTERIOR INSULATED FINISH SYSTEM <br />ELECTRIC <br />ELEVATOR <br />ELECTRICAL PANEL BOARD <br />ENCLOSURE <br />EMERGENCY <br />EQUAL <br />EQUIPMENT <br />ESTIMATE <br />EW <br />EWC <br />EXP <br />EXPO <br />EXST <br />EXT <br />FA <br />FB <br />FBO <br />FD <br />FDN <br />FE <br />FEC <br />FGL <br />FHC <br />FIN <br />FL <br />FLDG <br />FLUOR <br />F.N.D. <br />F.O. <br />F.O.C. <br />F.O.F. <br />F.O.M. <br />F.O.S. <br />FPRF <br />FR <br />FT <br />FTG <br />FURR <br />F.V. <br />GA <br />GALV <br />G.B. <br />G.I. <br />GI <br />GND <br />G.O. <br />GR <br />GYP <br />H <br />H.B. <br />HDBD <br />HDR <br />HDWD <br />HDW <br />H.M. <br />HORIZ <br />HR <br />HT <br />HTR <br />I.B.C. <br />I.B.O. <br />I.D. <br />INCL <br />INFO <br />INSUL <br />INT. <br />JAL <br />JAN <br />JST <br />JT. <br />KIT. <br />K.O. <br />L <br />LAB <br />LAM <br />LAV <br />LT. <br />MAX <br />M.C. <br />M.CL. <br />MED <br />MEM <br />MFR <br />M.H. <br />MIN. <br />MIR. <br />MISC. <br />M.O. <br />MTD <br />MTL <br />N <br />NAT <br />N.I.C. <br />NO. <br />NOM <br />N.T.S. <br />O.A. <br />OBS <br />O.C. <br />O.D. <br />EACH WAY <br />ELECTRIC WATER COOLER <br />EXPANSION <br />EXPOSED <br />EXISTING <br />EXTERIOR <br />FIRE ALARM <br />FIBERBOARD <br />FURNISHED BY OTHERS <br />FLOOR DRAIN <br />FOUNDATION <br />FIRE EXTINGUISHER <br />FIRE EXTINGUISHER CABINET <br />FIBERGLASS <br />FIRE HOSE CABINET <br />FINISH <br />FLOOR <br />FOLDING <br />FLUORESCENT <br />FEMININE NAPKIN DISPENSER <br />FACE OF <br />FACE OF CONCRETE <br />FACE OF FINISH <br />FACE OF MASONRY <br />FACE OF STUDS <br />FIREPROOF <br />FRAME <br />FOOT, FEET <br />FOOTING <br />FURRED, FURRING <br />FIELD VERIFY <br />GAGE, GAUGE <br />GALVANIZED <br />GRAB BAR <br />GALVANIZED IRON <br />GLASS <br />GROUND <br />GAS OUTLET <br />GRADE <br />GYPSUM <br />HIGH <br />HOSE BIB <br />HARDBOARD <br />HEADER <br />HARDWOOD <br />HARDWARE <br />HOLLOW METAL <br />HORIZONTAL <br />HOUR <br />HEAT <br />HEATER <br />INSTALLED BY CONTRACTOR <br />INSTALLED BY OWNER <br />INSIDE DIAMETER <br />INCLUDED, INCLUSIVE <br />INFORMATION <br />INSULATE(D), (ING) <br />INTERIOR <br />JALOUSIE <br />JANITOR <br />JOIST <br />JOINT <br />KITCHEN <br />KNOCKOUT <br />LONG, LENGTH <br />LABORATORY <br />LAMINATE <br />LAVATORY <br />LIGHT <br />MAXIMUM <br />MEDICINE CABINET <br />MODULAR CLOSET SYSTEM <br />MEDIUM <br />MEMBRANE <br />MANUFACTURER <br />MANHOLE <br />MINIMUM <br />MIRROR <br />MISCELLANEOUS <br />MASONRY OPENING <br />MOUNTED <br />METAL <br />NORTH <br />NATURAL <br />NOT IN CONTRACT <br />NUMBER <br />NOMINAL <br />NOT TO SCALE <br />OVERALL <br />OBSCURE <br />ON CENTER <br />OUTSIDE DIAMETER <br />O.F.C.I. <br />O.F.O.S. <br />OFF <br />O.H. <br />OPG <br />OPP <br />PC <br />PL <br />PL.LAM. <br />PLBG <br />PLYWD <br />PNL <br />PR <br />PT <br />P.T.D. <br />PTN <br />PVC <br />Q.T. <br />QTY <br />R. <br />R.D. <br />RDWD <br />REF <br />REINF <br />REV <br />RFL <br />R.H. <br />RID <br />R.L. <br />RM <br />R.O. <br />S.C. <br />SCHED <br />SCR <br />S.D. <br />SECT <br />SH <br />SHT <br />SIM <br />SL <br />SMACNA <br />SOLDR. <br />SPEC <br />SQ <br />SS <br />STA <br />STD <br />STL <br />STOR <br />STR <br />SUSP <br />SYS <br />SYM <br />T.B. <br />T.B.D <br />TEL <br />TEMP <br />T&G <br />THK <br />THR <br />TKBD <br />T.O. <br />T.O.B. <br />T.O.C. <br />T.O.F. <br />T.O.S. <br />T.O.W. <br />T.P.H. <br />TR <br />TV <br />TYP <br />U.O.I. <br />U.O.N. <br />U/S <br />V.B. <br />VER <br />VEST <br />V.T. <br />VWC <br />W <br />W/ <br />W.C. <br />WD <br />WDW <br />WH <br />W/O <br />WP <br />WPM <br />W.R. <br />WT <br />W.W.M. <br />OWNER FURNISHED CONTRACTOR <br />INSTALLED <br />OUTSIDE FACE OF STUD <br />OFFICE <br />OPPOSITE HAND <br />OPENING <br />OPPOSITE <br />PIECE <br />PLATE <br />PLASTIC LAMINATE <br />PLUMBING <br />PLYWOOD <br />PANEL <br />PAIR <br />POINT <br />PAPER TOWEL DISPENSER <br />PARTITION <br />POLYVINYL CHLORIDE <br />QUARRY TILE <br />QUANTITY <br />RISER; RADIUS <br />ROOF DRAIN <br />REDWOOD <br />REFERENCE <br />REINFORCED(ING) <br />REVISED, REVISION <br />REFLECTED <br />ROBE HOOK <br />RIDGE <br />ROWLOCK COURSE <br />ROOM <br />ROUGH OPENING <br />SOLID CORE <br />SCHEDULE <br />SCREEN <br />SOAP DISPENSER <br />SECTION <br />SHELF <br />SHEET <br />SIMILAR <br />SLOPE <br />SHEET METAL AND AIR CONDITIONING <br />CONTRACTORS NATIONAL ASSOCIATION <br />SOLDIER COURSE <br />SPECIFICATION <br />SQUARE <br />STAINLESS STEEL <br />STATION <br />STANDARD <br />STEEL <br />STORAGE <br />STRUCTURAL <br />SUSPENDED <br />SYSTEM <br />SYMMETRICAL <br />TOWEL BAR <br />TO BE DETERMINED <br />TELEPHONE <br />TEMPERED <br />TONGUE AND GROOVE <br />THICK <br />THRESHOLD <br />TACK BOARD <br />TOP OF <br />TOP OF BEAM <br />TOP OF CONCRETE <br />TOP OF FOOTING <br />TOP OF SLAB <br />TOP OF WALL <br />TOILET PAPER HOLDER <br />TREAD <br />TELEVISION <br />TYPICAL <br />UNLESS OTHERWISE INDICATED <br />UNLESS OTHERWISE NOTED <br />UNDERSIDE <br />VAPOR BARRIER <br />VERIFY <br />VESTIBULE <br />VINYL TILE <br />VINYL WALL COVERING <br />WIDE <br />WITH <br />WATER CLOSET <br />WOOD <br />WINDOW <br />WATER HEATER <br />WITHOUT <br />WATERPROOF <br />WATERPROOF MEMBRANE <br />WATER RESISTANT <br />WEIGHT <br />WELDED WIRE MESH <br />00 DOOR DESIGNATION <br />RE: DOOR SCHEDULE <br /># <br />A#.## <br />CALLOUT NUMBER <br />SHEET NUMBER, TYP. <br /># <br />SCALE <br />LOCATION <br />ELEVATION <br />ELEVATION DATUM <br />#REVISION NUMBER <br />AREA OF REVISION <br /># <br />A#.##EXTERIOR ELEVATION <br /># <br />A#.## <br />BUILDING SECTION <br />WALL SECTION <br />#VIEW TITLE <br />VIEW NUMBER <br />#WINDOW DESIGNATION <br />RE: WINDOW SCHEDULE <br />KEY NOTE <br />INTERIOR ELEVATION(S) <br />DIMENSION (TO FACE OF <br />STUD OR MASONRY) <br /># <br />#ROOF/CEILING SLOPE <br />(ELEVATION/SECTION) <br />0'-1" <br />EQ. EQ. <br />SLOPE SLOPE (ELEVATION) <br />#" per ft. <br />SLOPE (PLAN) <br />X"STEP IN SLAB <br /># <br />A#.## <br /># <br />A#.## <br /># <br /># <br />SLOPE <br />#" per ft. <br />00 <br />#" = #'-#" <br />STRUCTURAL GRID <br /># <br />P R O J E C T C O D E: <br />I S S U E D A T E: <br />R E V I S I O N S <br />S H E E T N U M B E R <br />D R A W I N G S <br />P R E P A R E D F O R : <br />S H E E T N A M E <br />1005 S. VIRLEE ST. <br />SANTA ANA, CA 92704 <br />OWNER: <br />SCOPE OF WORK <br />PROPERTY SUMMARY <br />BUILDING SUMMARY <br />AREA SUMMARY <br />PARKING SUMMARY <br />FIRE SPRINKLER SUMMARY <br />APPLICABLE CODES <br />SHEET INDEX <br />PROJECT TEAM <br />STRUCTURAL ENGINEER: <br />DESIGNER: <br />DRAWINGS, SPECIFICATIONS, AND <br />OTHER DOCUMENTS, INCLUDING THOSE <br />IN ELECTRONIC FORM, PREPARED BY <br />WANGTASTIC ARCHDESIGN LLC ARE <br />INSTRUMENTS OF SERVICE FOR USE <br />SOLELY WITH RESPECT TO THIS <br />PROJECT. WANGTASTIC ARCHDESIGN <br />LLC SHALL BE DEEMED THE AUTHORS <br />AND OWNERS OF THEIR RESPECTIVE <br />INSTRUMENTS OF SERVICE AND SHALL <br />RETAIN ALL COMMON LAW, STATUTORY <br />AND OTHER RESERVED RIGHTS, <br />INCLUDING COPYRIGHTS. VISUAL <br />CONTACT WITH THESE DOCUMENTS <br />CONSTITUTE PRIMA FACIE ACCEPTANCE <br />OF THESE CONDITIONS. <br />© WANGTASTIC ARCHDESIGN LLC 2023 <br />LEGAL DESCRIPTION: N TR 2535 LOT 28 <br />C: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />A <br />l <br />a <br />n <br /> <br />L <br />i <br />\ <br />D <br />e <br />s <br />k <br />t <br />o <br />p <br />\ <br />B <br />u <br />s <br />i <br />n <br />e <br />s <br />s <br />\ <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />a <br />l <br /> <br />P <br />r <br />o <br />j <br />e <br />c <br />t <br />s <br />\ <br />2 <br />0 <br />2 <br />3 <br /> <br />P <br />r <br />o <br />j <br />e <br />c <br />t <br />s <br />\ <br />0 <br />1 <br />4 <br />_ <br />M <br />S <br />A <br />_ <br />M <br />a <br />i <br /> <br />S <br />a <br />n <br />t <br />a <br />A <br />n <br />a <br /> <br />A <br />D <br />U <br />\ <br />3 <br />_ <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />2 <br />_ <br />R <br />e <br />v <br />i <br />t <br />\ <br />M <br />S <br />A <br />_ <br />M <br />a <br />i <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />A <br />D <br />U <br />. <br />r <br />v <br />t <br />4/ <br />3 <br />0 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />8 <br />: <br />4 <br />6 <br />: <br />4 <br />8 <br /> <br />P <br />M <br /> <br />MAI SANTA ANA ADU <br />10/09/2023 <br />CD / PERMIT <br />A0.0 <br />COVER SHEET <br />ANGIE MAI <br />23-014 <br />MA <br />I <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />A <br />D <br />U <br />10 <br />0 <br />5 <br /> <br />S <br /> <br />V <br />I <br />R <br />L <br />E <br />E <br /> <br />S <br />T <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />ADDRESS: <br />APN: <br />TRACT: <br />LOT: <br />ZONING: <br />SETBACK <br />FRONT: <br />CORNER SIDE: <br />INTERIOR SIDE: <br />REAR: <br />HEIGHT LIMIT: <br />1005 S VIRLEE ST, <br />SANTA ANA, CA 92704 <br />108-344-01 <br />2535 <br />28 <br />R-1 <br />REQUIRED PROPOSED <br />20' 84'-10" <br />10' 13'-6" <br />5' 6' <br />5' 6' <br />20' 19' - 11 1/4" <br />OCCUPANCY GROUP: <br />CONSTRUCTION TYPE: <br />STORIES: <br />DWELLING UNITS: <br />R3 & U <br />V-B <br />2 <br />2 <br />LOT AREA: <br />MAX LOT COVERAGE: <br />R OCCUPANCY <br />FIRST FLOOR <br />SECOND FLOOR <br />U OCCUPANCY <br />GARAGE <br />COVERED FRONT PORCH <br /> <br />TOTAL AREA <br />BLDG COVERAGE <br />EXISTING BUILDING AREA: <br />EXISTING FAR: <br />EXISTING LOT COVERAGE: <br />EXISTING OPEN SPACE AREA: <br />PROPOSED BUILDING AREA: <br />PROPOSED FAR: <br />PROPOSED LOT COVERAGE: <br />PROPOSED OPEN SPACE AREA: <br />MAIN HOUSE LIVING SF / ADU <br />LIVING SF RATIO: <br />7,438 SF <br />35% <br />EXISTING NEW TOTAL <br />1,370 SF 616 SF 1,986 SF <br />367 SF 367 SF <br /> 190 SF 254 SF 444 SF <br /> 60 SF 53 SF 113 SF <br />1,620 SF 1,290 SF 2,910 SF <br />1,620 SF 923 SF 2,543 SF <br />1,370 SF <br />1,370 / 7,438 = 0.18 <br />1,620 / 7,438 x 100% = 21.78% < 35% <br />3,974 SF <br />2,910 SF <br />2,910 / 7,438 = 0.39 <br />2,543 / 7,438 x 100% = 34.19% < 35% <br />2,698 SF <br />983 SF / 1,370 SF = 0.72 <br />EXISTING PARKING: <br />PROPOSED PARKING: <br />EXISTING: UNSPRINKLERED <br />PROPOSED: : UNSPRINKLERED <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA ENERGY CODE <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS <br />2022 CITY OF SANTA ANA MUNICIPAL CODE <br />ANGIE MAI <br />1005 S VIRLEE ST, <br />SANTA ANA, CA 92704 <br />P: 714.391.3764 <br />ANGIEMAI83@GMAIL.COM <br />1. APPLICATIONS FOR WHICH NO PERMIT IS ISSUED WITHIN 180 DAYS FOLLOWING THE DATE OF APPLICATION SHALL <br />AUTOMATICALLY EXPIRE. (R105.3.2 CRC) <br />2. EVERY PERMIT ISSUED SHALL BECOME INVALID UNLESS WORK AUTHORIZED IS COMMENCED WITHIN 180 DAYS AFTER ITS <br />ISSUANCE OR IF THE WORK AUTHORIZED IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS. A SUCCESSFUL INSPECTION <br />MUST BE OBTAINED WITHIN 180 DAYS. (R105.5 CRC) <br />3. THIS CONSTRUCTION REQUIRES THE INSTALLATION OF A PHOTOVOLTAIC SYSTEM IN COMPLIANCE WITH THE APPROVED <br />ENERGY COMPLIANCE. PLEASE INDICATE THIS ON THE COVER SHEET AS A DEFERRED SUBMITTAL. <br />4. ALL WORK SHALL COMPLY WITH ALL LOCAL BUILDING CODES, LAWS, ORDINANCES, RULES AND REGULATIONS OF THE <br />PUBLIC AUTHORITIES GOVERNING THE WORK. <br />5. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS FROM ALL AGENCIES HAVING JURISDICTION OVER <br />THE WORK, EXCEPT ONLY GENERAL BUILDING PERMIT. <br />6. VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE. DEVIATIONS FROM THE CONTRACT DOCUMENTS SHALL BE <br />REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. COMMENCEMENT OF WORK SHALL BE CONSTRUED AS <br />ACCEPTANCE OF ALL CONDITIONS, DIMENSIONS, AND SUBSTRATES. <br />7. DRAWINGS ARE NOT TO BE SCALED; USE WRITTEN DIMENSIONS ONLY. REPORT DIMENSIONAL DISCREPANCIES TO THE <br />ARCHITECT BEFORE PROCEEDING WITH THE WORK. <br />8. MAINTAIN A COMPLETE SET OF DRAWINGS AND SPECIFICATIONS ON THE JOB SITE AT ALL TIMES, INCLUDING COPIES OF ALL <br />THE ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS, CONSTRUCTION CHANGE AUTHORIZATIONS, REVIEWED SHOP DRAWINGS AND <br />PROJECT SUBMITTALS. <br />9. ALL MATERIALS, COMPONENTS, FINISHES, EQUIPMENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE SPECIFICATIONS <br />OR MANUFACTURER 'S RECOMMENDATIONS, OR INDUSTRY STANDARDS WHICHEVER IS MORE STRINGENT. <br />10. CONTRACTOR SHALL VERIFY ALL LOCATIONS OF TOILETS, VENTS, DUCTS, PLUMBING STACKS AND ANY OTHER <br />PENETRATION OF THE FLOOR CEILING ASSEMBLY. ALL PENETRATIONS SHALL NOT OCCUR ON ANY SECTION OF THE <br />FOUNDATIONS. NOTIFY ARCHITECTS OF ANY LOCATION THAT WOULD REQUIRE PENETRATION OF THE FOUNDATION. <br />11. ALL FINISH GRADES SHALL SLOPE AWAY FROM THE BUILDING AT 2% MINIMUM. <br />12. DAMP-PROOF ALL WALLS AND FOUNDATIONS BELOW GRADE. <br />13. STUD WALLS SHALL BE FIRE BLOCKED AT FLOOR, CEILING (INCLUDING FURRED AREAS), AND MID-HEIGHT OF STUD SPACES <br />MORE THAN 8'-0" HIGH. <br />14. ALL INSULATION SHALL BE CERTIFIED BY THE MANUFACTURER AS COMPLYING WITH THE CALIFORNIA QUALITY STANDARDS <br />FOR INSULATION MATERIAL. DOOR & WINDOWS BETWEEN CONDITIONED & UNCONDITIONED SPACE SHALL BE FULLY WEATHER- <br />STRIPPED. <br />15. FLASH EXTERIOR OPENINGS. WINDOW HEAD FLASHING TO LAP OVER JAMB FLASHING AND JAMB FLASHING TO LAP OVER <br />SILL FLASHING. <br />16. ALL DOORS, OVERHEAD DOORS, UTILITIES, PIPES, LADDERS, SCUPPER AND DOWNSPOUTS ARE TO BE PAINTED TO MATCH <br />THE ADJACENT MATERIAL. <br />17. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL <br />BE FINISHED WITH A NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET <br />ABOVE THE FLOOR. (R307.2) <br />18. BACK DRAFT DAMPERS ARE REQUIRED ON BATHROOM VENTILATION FANS, FANS MUST VENT THROUGH AN APPROVED <br />DUCT AND SHALL TERMINATE AT LEAST 3’ FROM AN OPENING OR PROPERTY LINE. <br />19. AN APPROVED SMOKE ALARM SHALL BE INSTALLED IN EACH SLEEPING ROOM AND HALLWAY OR AREA GIVING ACCESS TO A <br />SLEEPING ROOM, AND ON EACH STORY & BASEMENT FOR DWELLINGS WITH MORE THAN ONE STORY. SMOKE ALARMS SHALL BE <br />INTERCONNECTED SO THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS WITHIN THE INDIVIDUAL DWELLING UNIT. <br />IN NEW CONSTRUCTION SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER SOURCE FROM THE BUILDING WIRING & SHALL <br />BE EQUIPPED WITH BATTER BACK UP & LOW BATTERY SIGNAL. (R314) <br />20. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN <br />WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. CARBON <br />MONOXIDE ALARM SHALL BE PROVIDED OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY <br />OF THE BEDROOM(S) & ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. (R315) <br />21. FOR ROOF SLOPES < 2:12 SRI VALUES OF AT LEAST 75 OR BOTH A 3 YEAR SOLAR REFLECTANCE OF AT LEAST 0.75. <br />22. PROVIDE RAIN GUTTERS AND DOWNSPOUTS TO DRAIN ROOF WATER AND CARRY IT VIA NON -EROSIVE MEANS TO THE <br />STREET. GUTTERS SHALL BE SECURED AT LEAST EVERY 36" WITH MALLEABLE METAL HANGERS. <br />23. PROVIDE EMERGENCY EGRESS FROM SLEEPING ROOMS. SHOW DETAILS ON PLANS. MINIMUM - 24" CLEAR HEIGHT, 20" <br />CLEAR WIDTH, 5.7 SF MINIMUM AREA (5.0 SF AT GRADE LEVEL) & 44" MAXIMUM TO SILL. (R310.2.1) <br />24. BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION <br />PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. (R319) <br />25. PV SYSTEM WILL BE REQUIRED. SOLAR SYSTEM WILL BE SUBMITTED UNDER A SEPARATE SUBMITTAL AND SHALL BE <br />APPROVED AND PERMITTED PRIOR TO BUILDING FRAME INSPECTION IS SCH EDULE. <br />WANGTASTIC ARCHDESIGN LLC <br />6302 E 142ND PL <br />THORNTON, CO 80602 <br />P: 720.238.9094 <br />WANGTASTICARCHDESIGN@GMAIL.COM <br />RL ENGINEERING <br />20716 ARLINE AVE. <br />LAKEWOOD, CA 90715 <br />P: 415.887.8691 <br />RONG.RLENGR@GMAIL.COM <br />1 COVERED PARKING SPACE (HOUSE) <br />1 COVERED PARKING SPACE (ADU) <br />SHEET NUMBER SHEET NAME <br />A0.0 COVER SHEET <br />A1.0 EXISTING SITE PLAN <br />A1.1 SITE PLAN <br />A2.1 FLOOR PLANS <br />A2.2 ROOF PLAN <br />A3.1 EXTERIOR ELEVATIONS <br />A4.1 BUILDING SECTIONS <br />A7.1 DETAILS <br />SN1 GENERAL NOTES <br />S1 FOUNDATION PLAN <br />S2 FLOOR FRAMING PLAN <br />S3 ROOF FRAMING PLAN <br />SD1 STRUCTURAL DETAILS <br />SD1.1 STRUCTURAL DETAILS <br />SD2 STRUCTURAL DETAILS <br />SD3 STRUCTURAL DETAILS <br />SD4 STRUCTURAL DETAILS <br />1 of 3 RESIDENTIAL T24 SHEET <br />2 of 3 RESIDENTIAL T24 SHEET <br />3 of 3 RESIDENTIAL T24 SHEET <br />NEW DETACHED ACCESSORY DWELLING UNIT, INCLUDING: <br />- TWO BEDROOMS <br />- TWO BATHROOM <br />- ONE LOFT AREA <br />- KITCHEN AND LIVING AREA <br />DEMOLISION OF UNPERMITTED STORAGE ON EXISTING SINGLE FAMILY <br />DWELLING <br />DATE NO. DESCRIPTION <br />02/23/2024 1 BUILDING <br />COMMENTS <br />04/23/2024 2 BUILDING <br />COMMENTS <br />2 <br />Bldg# 101118024 <br /> <br />APPROVALS: <br />PLNG - PRaj <br />BLDG - TLe <br />POLICE - BMartin <br />1005 S Virlee St <br />Unit# 28/26/2024