Laserfiche WebLink
Standard Loading Comparison (Roof 1) <br />Without Solar With Solar <br />Dead Load <br />Clay Tile 10 10 psf <br />1/4" Plywood 1 1 psf <br />Framing 4 4 psf <br />Insulation 1 1 psf <br />1/2" Gypsum Ceiling 2 2 psf <br />M,E, & Misc 1.5 1.5 psf <br />Solar Panel 0 3 psf <br />Total Dead Load 19.5 22.5 psf <br />Snow Load <br />Ground Snow Load, Pg psf <br />Exposure Factor, Ce <br />Thermal Factor, Ct <br />Importance Factor, Is <br />Flat Roof Snow Load ASCE 7 Eqn. 7.3-1 or jurisdiction min. <br />Slope degrees <br />Unobstructed Slippery Surface?No No <br />Slope Factor, Cs 1.00 1.00 <br />Sloped Roof Snow Load 0.0 0.0 psf <br />Live Load <br />Roof Live Load 20 0 psf <br />Load Combination <br />D + Lr 39.5 22.5 psf <br />D + S 19.5 22.5 psf <br />Max. Load 39.5 22.5 psf <br />% of original 56.96% <br />Result: <br />This calculation justifies the additional solar load by comparing existing to proposed gravity loads <br />in the location of the solar panels. <br />Because the total forces are decreased, per the relevant code <br />provisions stated in the body of the letter, the existing roof <br />structure is permitted to remain unaltered. <br />0 <br />1.1 <br />20 <br />1 <br />1.00 <br />0 <br />1012 N King St <br />1/23/2025