My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1012 N King St - Plan
PBA
>
Building
>
ProjectDox
>
K
>
King St
>
1012 N King St
>
1012 N King St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:53:51 AM
Creation date
6/1/2025 11:53:44 AM
Metadata
Fields
Template:
Plan
Permit Number
20184915
101122236
Full Address
1012 N King St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
December 11, 2024 <br />Subject: Proposed Solar Panel Installation <br />Rosales, Rogelio Residence, 1012 N King St, Santa Ana, CA <br />Job #001-04502 <br />To Whom it May Concern, <br />Design Parameter Summary <br />Governing Building Code: 2022 California Residential Code <br />Risk Category: II <br />Wind Exposure: C <br />Design Wind Speed: 115 mph <br />Ground Snow Load: 0 psf <br />Roof Information <br />Roofing Material: Clay Tile, Mod Bit <br />Roof Slope: 20, 1 degrees <br />We have reviewed information, provided by our client, related to the proposed solar panel installation at the above-referenced address. <br />The purpose of the review was to determine if the existing roof is structurally adequate for the proposed installation. Based on our review <br />and analysis of the given information, and in accordance with governing building codes, I certify that the capacity of the structural roof <br />framing that directly supports the additional gravity loading due to the solar panel supports and modules had been reviewed and <br />determined to meet or exceed the requirements in accordance with the Design Criteria. <br />Engineering Analysis <br />Lag Screws: 2 screws, 5/16" dia min., with min. 2.5" embedment into roof truss top chord only, at 72" O.C. max <br />Roof Structure: 2x4 Manufactured Trusses @ 24" O.C. (assumed) <br />Roof Connection Details (Roof 1) <br />Roof Connection Details (Roof 2) <br />Lag Screws: 1 screws, 5/16" dia min., with min. 2.5" embedment into roof truss top chord only, at 72" O.C. max <br />Wind uplift on the panels has been calculated in accordance with the relevant provisions of ASCE 7-16. This loading has been used to <br />verify the adequacy of the connection specified above. Connection locations should be in accordance with design drawings. <br />Stagger attachments to avoid overloading any individual truss top chord. <br />The proposed installation will be 6" max. above the roof surface (flush mounted) and parallel to the roof surface. Therefore, any <br />increase in wind loading on the building structure from the solar panel installation is expected to be negligible. Wind is the governing <br />lateral load case. Because the increase in lateral loading is not increased by more than 10%, per provisions in the adopted building <br />codes, the structure need not be altered for lateral loading. <br />Everest K2 Systems Crossrail 44-X rails will support the modules and will fasten to the roof structure with Everest K2 Flat Tile Hook <br />and K2 Big Foot along the rail. <br />The proposed installation - including weight of panels, racking, mounts, and inverters where applicable - will be approximately 3 psf. In <br />the areas where panels are installed, roof live loads will not be present. The reduction of roof live load is adequate to fully or partially <br />compensate for the addition of the panel installation. Because the member forces in the area of the solar panels are not increased by <br />more than 5%, and so per provisions in the adopted building codes, the structure need not be altered for gravity loading. <br />1012 N King St <br />1/23/2025
The URL can be used to link to this page
Your browser does not support the video tag.