Laserfiche WebLink
REV: H <br />AHJ: CA-CITY OF SANTA ANA <br />33.770878, -117.879538 <br />APN: 00123127 <br />NAME: MICHAEL LANGSTON & <br />CHRISTOPHER CLEARY <br />DRAFTED BY: K.NISHANTH <br />ADDRESS: 1024 SHARON RD, SANTA <br />ANA, CA 92706 <br />UTILITY: SCE-SOUTHERN <br />CALIFORNIA EDISON <br />SCALE: AS NOTED <br />PRN NUMBER: SMT-87593 <br />PAPER SIZE: 17"X11"SHEET: CS-01DATE: 05/09/2024 <br />DRAWING INFORMATION <br />CUSTOMER INFORMATION CONTRACTOR INFORMATION <br />QC'ED BY: J.ABINESH <br />PHONE NUMBER: (714) 225-5477 <br />AERIAL MAP VICINITY MAP <br />HOUSE VIEW <br />COVER SHEET <br />MICHAEL LANGSTON & CHRISTOPHER CLEARY - 10.935kW DC, 7.830kW AC, 9.855kW CEC AC RATING, 20.16kWh <br />ENERGY STORAGE SYSTEM <br />APPLICABLE CODES <br />· ELECTRIC CODE:CEC 2022 <br />· FIRE CODE:CFC 2022 <br />· BUILDING CODE:CBC 2022 <br />· RESIDENTIAL CODE:CRC 2022 <br />10935W DC, 7830W AC, 9855W CEC AC <br />RATING, 20.16 kWh ENERGY STORAGE <br />SYSTEM <br />SCOPE OF WORK <br />BATTERY: <br />INVERTER: <br />MODULES: <br />SYSTEM SIZE: <br />(2)ENPHASE ENCHARGE 10 <br />(ENCHARGE-10-1P-NA) <br />(1)ENPHASE IQ SYSTEM CONTROLLER 2 <br />(EP200G101-M240US01) <br />(27) HANWHA QCELLS Q.PEAK DUO BLK <br />ML-G10+ 405 (405W) <br />(27) ENPHASE IQ8PLUS-72-2-US (240V) <br />[SI-1] <br />MAIN BREAKER DERATE:REPLACE EXISTING MAIN <br />BREAKER WITH NEW 175A MAIN BREAKER <br />1. MODULES ARE LISTED UNDER UL 1703 / 61730 AND CONFORM TO THE STANDARDS. <br />2. INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. <br />3. DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE <br />CONDITION MIGHT VARY. <br />4. WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH <br />CEC 110.26. <br />5. ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. <br />6. ALL CONDUCTORS SHALL BE 600V, 90°C STANDARD COPPER UNLESS OTHERWISE NOTED. <br />7. WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. <br />8. THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION <br />AND/OR THE UTILITY. <br />9. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS <br />OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION <br />WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. <br />10. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING. <br />GENERAL NOTES <br />BRANCH DETAILS: <br />1X9, 1X9, 1X9 ENPHASE BRANCHES <br />RISK CATEGORY- ll <br />BASIC WIND SPEED = 95 MPH @ 3-SEC GUST <br />GROUND SNOW LOAD = 0 PSF <br />DESIGN CRITERIA <br />PROJECT WINDSPEED DETERMINED USING THE <br />ASCE 7 STANDARD UNLESS DIRECTED OTHERWISE <br />BY LOCAL JURISDICTION AMENDMENTS <br />ROOF AREA CALCULATION <br />TOTAL ARRAY AREA = 570.26 sq.ft <br />TOTAL ROOF AREA = 3329 sq.ft <br />% ARRAY AREA IN ROOF = 17.13 % <br />SHEET CATALOG <br />SHEET REVISION DESCRIPTION <br />CS-01 COVER SHEET <br />CS-02 GENERAL NOTES <br />E-01 SITE PLAN <br />S-01 MOUNTING DETAILS <br />S-02 STRUCTURAL DETAILS <br />E-02 SINGLE LINE DIAGRAM <br />E-03 ELECTRICAL CALCULATIONS <br />E-04 EQUIPMENT ELEVATION <br />VIEW-1 <br />E-04.1 EQUIPMENT ELEVATION <br />VIEW-2 <br />E-04.2 LOAD CALCULATION <br />E-04.3 PANEL SCHEDULE <br />PL-01 PLACARDS <br />SS SPEC SHEET(S) <br />H <br />H <br />H <br />H <br />H <br />H <br />H <br />H <br />H <br />H <br />SOLARMAX RENEWABLE ENERGY <br />PROVIDER INC. <br />3080 12TH ST, RIVERSIDE, CA 92507 <br />TEL: (951) 300-0788 <br />LICENSE NUMBER& <br />CLASS:972048/C-46 <br />David Bingwen Hsu <br /> David Bingwen Hsu, Lic. Holder <br />H <br />H <br />H <br />B The scope of the plans is for the installation of the solar photovoltaic <br />system only and the approval is subject to compliance with all applicable <br />city and state codes and regulations regarding construction. The approval <br />of the plans does not constitute any certification of the accuracy, <br />completeness, or building permit status of the existing buildings and <br />structures as shown. <br />Bldg# 101118486 <br />Elec# 20182270 <br /> <br />APPROVALS: <br />ELEC - MSmith <br />1024 W Sharon Rd - <br />201822705/28/2024