Laserfiche WebLink
AC <br />B <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />BBB <br />C <br />B <br />BB <br />BB <br />CCC <br />CCCCC MS <br />P <br />BT <br />CT <br />CB <br />JB <br />AC <br />RS <br />D <br />BT <br />SBSB <br />REV: H <br />AHJ: CA-CITY OF SANTA ANA <br />33.770878, -117.879538 <br />APN: 00123127 <br />NAME: MICHAEL LANGSTON & <br />CHRISTOPHER CLEARY <br />DRAFTED BY: K.NISHANTH <br />ADDRESS: 1024 SHARON RD, SANTA <br />ANA, CA 92706 <br />UTILITY: SCE-SOUTHERN <br />CALIFORNIA EDISON <br />SCALE: AS NOTED <br />PRN NUMBER: SMT-87593 <br />PAPER SIZE: 17"X11"SHEET: E-01DATE: 05/09/2024 <br />DRAWING INFORMATION <br />CUSTOMER INFORMATION CONTRACTOR INFORMATION <br />QC'ED BY: J.ABINESH <br />PHONE NUMBER: (714) 225-5477 <br />SCALE:1"=20'-0"SITE PLAN <br />MICHAEL LANGSTON & CHRISTOPHER CLEARY - 10.935kW DC, 7.830kW AC, 9.855kW CEC AC RATING, 20.16kWh <br />ENERGY STORAGE SYSTEM <br />10935W DC, 7830W AC, 9855W CEC AC <br />RATING, 20.16 kWh ENERGY STORAGE <br />SYSTEM <br />SCOPE OF WORK <br />BATTERY: <br />INVERTER: <br />MODULES: <br />SYSTEM SIZE: <br />(2)ENPHASE ENCHARGE 10 <br />(ENCHARGE-10-1P-NA) <br />(1)ENPHASE IQ SYSTEM CONTROLLER 2 <br />(EP200G101-M240US01) <br />(27) HANWHA QCELLS Q.PEAK DUO BLK <br />ML-G10+ 405 (405W) <br />(27) ENPHASE IQ8PLUS-72-2-US (240V) <br />[SI-1] <br />MAIN BREAKER DERATE:REPLACE EXISTING MAIN <br />BREAKER WITH NEW 175A MAIN BREAKER <br />ROOF AREA CALCULATION <br />TOTAL ARRAY AREA = 570.26 sq.ft <br />TOTAL ROOF AREA = 3329 sq.ft <br />% ARRAY AREA IN ROOF = 17.13 % <br />BRANCH DETAILS: <br />1X9, 1X9, 1X9 ENPHASE BRANCHES <br />SOLARMAX RENEWABLE ENERGY <br />PROVIDER INC. <br />3080 12TH ST, RIVERSIDE, CA 92507 <br />TEL: (951) 300-0788 <br />LICENSE NUMBER& <br />CLASS:972048/C-46 <br />David Bingwen Hsu <br /> David Bingwen Hsu, Lic. Holder <br />(E) UTILITY METER WITH <br />(E) MAIN SERVICE PANEL (EXTERIOR) <br />(N) (1)ENPHASE ENCHARGE 10 (EXTERIOR) <br />(N) ENPHASE RAPID SHUTDOWN SWITCH (EXTERIOR) <br />CONDUIT RUN <br />PERIMETER FENCE <br />GATE <br />1'-6" FIRE SETBACKDR <br />I <br />V <br />E <br />W <br />A <br />Y <br />SHARON RD <br />(N) JUNCTION BOX (ROOF-MOUNTED) <br />DETACHED STRUCTURE <br />(N) (1)ENPHASE ENCHARGE 10 (EXTERIOR) <br />NOTE: <br />1. INDICATE DEDICATED CLEAR UNOBSTRUCTED WORKING SPACE IN FRONT OF DISCONNECTING <br />MEANS, NOT BE LESS THAN 3 FOOT DEEP BY 2.5 FEET-WIDE FROM STANDING SURFACE TO NOT <br />LESS THAN 6.5 FEET IN HEIGHT. <br />NOTE: <br />1. EXTERIOR ESS UNIT(S) WILL NOT BE INSTALLED WITHIN 3 FEET (IN ANY DIRECTION) OF ANY <br />DOORS, WINDOWS, OPERABLE OPENINGS INTO BUILDINGS AND HVAC INLETS. <br />(N) ENPHASE IQ COMBINER 4/4C (EXTERIOR) <br />(E) SUB PANEL-1 (INTERIOR) <br />RESIDENCE <br />STRING CONFIGURATION <br />BRANCH DETAILS <br />A 9 MICROINVERTERS <br />B 9 MICROINVERTERS <br />C 9 MICROINVERTERS <br />TOTAL NUMBER OF STORY: 1 <br />147'-10" <br />140'-4" <br />79'-9" <br />GATE <br />GATE <br />GATE <br />POOL <br />DETACHED <br />PERGOLAS <br />PERGOLA <br />47'-4" <br />36'-4" <br />5'-5" <br />WALKWAY <br />WA <br />L <br />K <br />W <br />A <br />Y <br />WA <br />L <br />K <br />W <br />A <br />Y <br />WA <br />L <br />K <br />W <br />A <br />Y <br />3'-1" <br />(N) ENPHASE IQ SYSTEM CONTROLLER 2 (EXTERIOR) <br />(N) ESS DISCONNECT (EXTERIOR) <br />(N) AC DISCONNECT (EXTERIOR) <br />(E) SUB PANEL-2 (INTERIOR) <br />B <br />1024 W Sharon Rd - <br />201822705/28/2024