Laserfiche WebLink
Page 5 of 8 <br />1760 Chicago Ave Ste J13, Riverside, CA 92507 (951) 405-1733 info@currentrenewableseng.com <br />Roof Framing Checks: <br />Force Checks <br />LC1: D+S <br />Roof 1 <br />Applied Moment (lb-ft):199.7 <br />Applied Shear (lbs):148.5 <br />Allowable Moment (lb-ft):455.6 <br />Allowable Shear (lbs):724.5 <br />Moment DCR:0.438 <br />Shear DCR:0.205 <br />LC2: D+0.6W <br />Roof 1 <br />Applied Moment (lb-ft):322.5 <br />Applied Shear (lbs):239.8 <br />Allowable Moment (lb-ft):633.9 <br />Allowable Shear (lbs):1,008.0 <br />Moment DCR:0.509 <br />Shear DCR:0.238 <br />LC3: D+0.75(S+0.6W) <br />Roof 1 <br />Applied Moment (lb-ft):291.8 <br />Applied Shear (lbs):217.0 <br />Allowable Moment (lb-ft):633.9 <br />Allowable Shear (lbs):1,008.0 <br />Moment DCR:0.460 <br />Shear DCR:0.215 <br />LC4: 0.6D+0.6W <br />Roof 1 <br />Applied Moment (lb-ft):242.7 <br />Applied Shear (lbs):180.4 <br />Allowable Moment (lb-ft):633.9 <br />Allowable Shear (lbs):1,008.0 <br />Moment DCR:0.383 <br />Shear DCR:0.179 <br />1028 S Maxine St <br />07/28/23