Laserfiche WebLink
~123.85' <br />~5 <br />1 <br />. <br />4 <br />6 <br />' <br />~116.29' <br />4' <br />- <br />1 <br />" <br />18'-3" <br />3' <br />- <br />1 <br />0 <br />" <br /> <br />34'-0" <br />~5 <br />4 <br />. <br />5 <br />3 <br />' <br />MSP LC ACD <br />JB <br />UM CB <br />MSP LC ACDUM CB <br />JB <br />SITE PLAN WITH ROOF PLAN <br />SHEET NAME <br />SHEET NUMBER <br />PV-1 <br />PROJECT NAME <br />TH <br />I <br />E <br />N <br />A <br />N <br /> <br />V <br />A <br />N <br />1 <br />0 <br />2 <br />8 <br /> <br />S <br /> <br />M <br />A <br />X <br />I <br />N <br />E <br /> <br />S <br />T <br /> <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br /> <br />U <br />S <br />A <br />AP <br />N# <br /> <br />1 <br />0 <br />8 <br />5 <br />9 <br />1 <br />8 <br />7 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />DEL MAR, CA 92014, USA <br />REVDATE DESCRIPTION <br />VERSION <br />UR05/16/2023 INITIAL RELEASE <br />DESIGN SUPPORT DAY OF INSTALL: <br />CHAT.POWUR.COM <br />SITE PLAN WITH <br />ROOF PLAN <br />1 SCALE: 3/32" = 1'-0" <br />NOTE: <br />A. ALL ELECTRICAL EQUIPMENT, INVERTERS/COMBINER, <br />DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL <br />NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ <br />SUPPLY OR DEMAND PIPING. <br /> ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE <br />THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS <br />OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN <br />LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. <br />NOTE: <br />3/4" OR GREATER EMT CONDUIT <br />RUN (7/8" ABOVE ROOF) <br />LEGEND <br />AC DISCONNECT <br />JUNCTION BOX <br />ACD <br />JB <br />MSP MAIN SERVICE PANEL <br />GATE <br />FENCE <br />TREES <br />ENPHASE IQ COMBINER 4 <br />X2-IQ-AM1-240-4 (IEEE 1547:2018)CB <br />UTILITY METERUM <br />VENT, ATTIC FAN (ROOF OBSTRUCTION) <br />PROPERTY LINE <br />EXISTING <br />DRIVEWAY <br />(E) <br />SHED <br />S <br />M <br />A <br />X <br />I <br />N <br />E <br /> <br />S <br />T <br />TWO- STORY <br />HOUSE <br />ROOF ACCESS POINT <br />ROOF ACCESS POINT <br />(E)08 - SUNPOWER SPR-X20-250-BLK <br />(250)MODULES <br />LC LOAD CENTER <br />6/30/2024 <br />STAMPED 07/06/2023 <br />STRUCTURAL NOTES : <br />1. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE <br />COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE <br />PROPOSED PV INSTALLATION ONLY. <br />2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. <br />3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS <br />MUST FOLLOW MANUFACTURER GUIDELINES AND <br />REQUIREMENTS. <br />4. PLEASE SEE THE ACCOMPANYING STRUCTURAL <br />CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. <br />5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR <br />INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE <br />INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY <br />INCONSISTENCY BETWEEN SITE VERIFICATION AND <br />FOLLOWING: 2x4 TRUSSES @ 24" OC SPACING WITH MAX <br />UNSUPPORTED SPAN EQUAL OR LESS THAN 8 FT. <br />1028 S Maxine St <br />07/28/23