My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1025 N Mirasol St - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Mirasol St
>
1025 N Mirasol St
>
1025 N Mirasol St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:53:59 AM
Creation date
6/1/2025 11:53:51 AM
Metadata
Fields
Template:
Plan
Permit Number
20178523
101113588
Full Address
1025 N Mirasol St
Document Relationships
101113588 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Mirasol St\1025 N Mirasol St
20178523 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Mirasol St\1025 N Mirasol St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CAUTION: <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS LOCATED <br />AS SHOWN <br />NOTES AND SPECIFICATIONS: <br />x SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF <br />THE CEC 2016 ARTICLE 110.21(B), UNLESS SPECIFIC <br />INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF <br />REQUESTED BY THE LOCAL AHJ. <br />x SIGNS AND LABELS SHALL ADEQUATELY WARN OF <br />HAZARDS USING EFFECTIVE WORDS, COLORS AND <br />SYMBOLS. <br />x LABELS SHALL BE PERMANENTLY AFFIXED TO THE <br />EQUIPMENT OR WIRING METHOD AND SHALL NOT BE <br />HAND WRITTEN. <br />x LABEL SHALL BE OF SUFFICIENT DURABILITY TO <br />WITHSTAND THE ENVIRONMENT INVOLVED. <br />x SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, <br />PRODUCT SAFETY SIGNS AND LABELS, UNLESS <br />OTHERWISE SPECIFIED. <br />x DO NOT COVER EXISTING MANUFACTURER LABELS. <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND MAY BE <br />ENERGIZED <br />ELECTRICAL SHOCK HAZARD <br />WARNING ! <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECTS. <br />PER CODE(S): CEC 2016: 690.35(F), NEC <br />2014: 690.35(F), NEC 2011: 690.35(F) <br />WARNING! <br />SOURCES: UTILITY GRID <br />AND PV SOLAR ELECTRIC <br />SYSTEM <br />DUAL POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN <br />SERVICE PANEL. <br />PER CODE(S): NEC 2014: 705.12(D)(3), <br /> NEC 2011: 705.12(D)(4) <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />LABEL LOCATION: <br />INVERTER(S), ENPHASE ENVOY <br />ENCLOSURE (IF APPLICABLE). <br />PER CODE(S): CEC 2019: 690.15, <br />NEC 2014: 690.5(C), NEC 2011: 690.5(C) <br />! <br />ELECTRICAL SHOCK HAZARD <br />WARNING ! <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC <br />COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2019: 690.17(B), <br />NEC 2014: 690.17(E), NEC 2011: 690.17(4) <br />WARNING ! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER (IF <br />APPLICABLE). <br />PER CODE(S): CEC 2019: 705.12(B), <br />NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: <br />705.12(D)(7) <br />! <br />DO NOT ADD LOADS <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />WARNING <br />LABEL LOCATION: <br />PHOTOVOLTAIC AC COMBINER (IF <br />APPLICABLE). <br />PER CODE(S): CEC 2016: <br />705.12(D)(2)(3)(c), NEC 2014: <br />705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, <br />AT EACH TURN, ABOVE AND BELOW PENETRATIONS, <br />ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): CEC 2019: 690.13, NEC 2014: 690.31(G)(3), <br />690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC <br />2012: 605.11.1.4 <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2019: 690.53, NEC 2014: 690.54, NEC <br />2011: 690.54 <br />PHOTOVOLTAIC AC DISCONNECT <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH RAPID SHUTDOWN <br />LABEL LOCATION: <br />WEATHER RESISTANT MATERIAL, DURABLE PLAQUE, UL969 AS STANDARD TO WEATHER RATING (UL <br />LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, <br />PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN <br />DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.12, 690.56(C)) <br />OTHERWISE SPECIFIED. <br />x D O NOT COVER EXISTIN G MANUFACTURER LABELS.SOLAR PV SYSTEM <br />EQUIPPED WITH RAPID <br />SHUTDOWN <br />TURN RAPID <br />SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUTDOWN PV <br />SYSTEM AND <br />REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR <br />ELECTRIC <br />PV PANELS <br />MS <br />P <br />UM <br />LC <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />DATE DESCRIPTION <br />REVISIONS <br />PV-6 <br />HOMEOWNER INFO <br />11" X 17" <br />SIGNATURE & SEAL <br />CONTRACTOR <br />AD <br />R <br />I <br />A <br />N <br /> <br />V <br />E <br />G <br />A <br />10 <br />2 <br />5 <br /> <br />M <br />I <br />R <br />A <br />S <br />O <br />L <br /> <br />S <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br />AN <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />, <br /> <br />U <br />S <br />A <br />NAME: SUNERGY, INC. <br />ADDRESS: 23182 ALCALDE DR SUITE <br />GLAGUNA HILLS, CA 92653 <br />PHONE: (562) 544-7394 <br />LICENSE #: 1061794 <br />APN: - <br />EMAIL: - <br />PHONE: - <br />0012/19/2022 Initial Design <br />PLACARDS <br /> <br />PV ARRAY <br />COMBINER PANEL <br />UTILITY METER <br />MAIN SERVICE PANEL10 <br />2 <br />5 <br /> <br />M <br />I <br />R <br />A <br />S <br />O <br />L <br /> <br />S <br />T <br />1025 N Mirasol St <br />01/27/23
The URL can be used to link to this page
Your browser does not support the video tag.