Laserfiche WebLink
ELECTRICAL NOTES <br />1) ALL GROUNDING TO COMPLY WITH NEC 690.47. <br />2) ROOFTOP CONDUIT SHALL BE LOCATED MIN. 7/8" ABOVE ROOF SURFACE. <br />3) ALL TERMINALS SHALL BE MIN. 75°C RATED. <br />SYSTEM SUMMARY STC (5.2 kW DC / 4.225 kW AC) <br />STC DC: (13) 400W = 5.2 kW <br />STC AC: (13) 325W = 4.225 kW <br />● (13) SOLARIA POWER X-400R (400W) MODULES MODULES <br />● (13) IQ8M-72-2-US (240V) MICROINVERTERS <br />● 1x BRANCH OF 7 CONNECTED IN PARALLEL <br />● 1x BRANCH OF 6 CONNECTED IN PARALLEL <br />1 <br />1 <br />2 <br />G <br />2 1 <br />1 <br />2 <br />G <br />7 <br />MOD: SOLARIA POWER X-400R (400W) <br />MODULES <br />INV: IQ8M-72-2-US (240V) (240V) <br />(1 BRANCH X 7 MICRO-INV) <br />1 <br />1 <br />2 <br />G <br />2 1 <br />1 <br />2 <br />G <br />6 <br />MOD: SOLARIA POWER X-400R (400W) <br />MODULES <br />INV: IQ8M-72-2-US (240V) (240V) <br />(1 BRANCH X 6 MICRO-INV) <br />1 <br />2 <br />1 <br />2 <br />G <br />N <br />JUNCTION BOX <br />600V, NEMA 3R <br />UL LISTED <br />G <br />N <br />20A(N) <br />20A(N) <br />IQ COMBINER PANEL <br />WITH ENPHASE ENVOY <br />XAM1-120 (OR EQUIV) <br />TO <br />UTILITY <br />GRID <br />M <br />BI-DIRECTIONAL <br />UTILITY METER <br />UTILITY: SOUTHERN <br />CALIFORNIA EDISON CO <br />SERVICE: 240V 60HZ 1PH <br />G <br />N <br />200A(N) <br />30A(N) <br />MAIN SERVICE PANEL <br />(NEW, BOTTOM-FED) <br />BUS RATING: 225A <br />MAIN BREAKER: 200A (N) <br />MS-01 <br />MS-02 <br />MCB-01 <br />MCB-02 <br />LC-01 <br />AC wire details <br />Wire Min Ampacity Live Neutral Ground Min EMT Min PVC Min RMC <br />MS-01 11.81A (2)10 AWG PV 10 AWG PV 06 AWG BARE <br />(NOT IN CONDUIT)- - - <br />MS-02 10.13A (2)10 AWG PV 10 AWG PV 06 AWG BARE <br />(NOT IN CONDUIT)- - - <br />MCB-01 11.81A (2)10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 1/2 in 1/2 in 1/2 in <br />MCB-02 10.13A (2)10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 1/2 in 1/2 in 1/2 in <br />LC-01 21.94A (2)10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 1/2 in 1/2 in 1/2 in <br />UTILITY FEED + TOTAL BACKFEED <br />200A + 25A = 225A <br />LESS OR EQUAL TO <br />BUS RATING x 120% <br />225A x 120% = 270A <br />INTERCONNECTION 120% RULE <br />(MAIN PANEL) <br />CALCULATION ENSURES BUS IS <br />SAFE REGARDLESS OF LOADS <br />Isc(25°C) = 13.68A, Tisc = 0.048A/°C <br />Isc(T) = Isc(25°C) + [Tisc x (T-25°C)] <br />Isc(2°C) = 12.58A, Isc(31°C) = 13.97A <br />Voc(25°C) = 37.30V, Tvoc = -0.280V/°C <br />Voc(T) = Voc(25°C) + [Tvoc x (T-25°C)] <br />Voc(2°C) = 43.74V, Voc(31°C) = 35.62V <br />EXTREME CASE MODULE OUTPUT <br />(SOLARIA POWER X-400R (400W) MODULES) <br />EE <br />TO CONSUMPTION CT <br />CT <br />CT <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />DATE DESCRIPTION <br />REVISIONS <br />PV-4 <br />HOMEOWNER INFO <br />11" X 17" <br />SIGNATURE & SEAL <br />CONTRACTOR <br />AD <br />R <br />I <br />A <br />N <br /> <br />V <br />E <br />G <br />A <br />1 <br />0 <br />2 <br />5 <br /> <br />M <br />I <br />R <br />A <br />S <br />O <br />L <br /> <br />S <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br />AN <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />, <br /> <br />U <br />S <br />A <br />NAME: SUNERGY, INC. <br />ADDRESS: 23182 ALCALDE DR SUITE <br />GLAGUNA HILLS, CA 92653 <br />PHONE: (562) 544-7394 <br />LICENSE #: 1061794 <br />APN: - <br />EMAIL: - <br />PHONE: - <br />0012/19/2022 Initial Design <br />ELECTRICAL THREE LINE DIAGRAM <br />SCALE: NTS <br />THREE LINE <br />DIAGRAM <br />1025 N Mirasol St <br />01/27/23