FLUSH MOUNTED SOLAR PANELS <br />Type of Roof Hip <br />Roof Slope -  = Angle of plane of roof from horizontal, in degrees <br /> = 20 deg <br />Mean Roof Height - Eave height will be used for  <= 10deg <br />h = 15 ft <br />Building dimensions s1 = 30 ft <br />s2 = 30 ft <br />a = 10% of least horizontal dimension or 0.4h, whichever is smaller, but not less than 4% of the least <br /> horizontal direction or 3 ft <br />a = 3 ft <br />B = Horizontal dimension of building normal to wind direction, in ft. <br />B = 20 ft Horizontal dimension of building <br />Attachment Spacing <br />Effective Area A = 15 ft2 <br />p = qh(GCp)(E)(a) 29.4-7 <br />Velocity pressure Exposure Coefficients <br />ROOF OVERHANG Wind Exposure C <br />(GCp)down =0.63 0.63 Kzt =1 <br />(GCp)upz1 =-1.72 -2.22 Kd =0.85 <br />(GCp)upz2r =-2.13 -2.82 Kz =0.85 <br />(GCp)upz2e =-2.37 -2.89 Ke =1 <br />(GCp)upz3 =-2.37 -3.34  E =1 <br />a =0.73 <br />V =95 mph <br />qh = 0.00256KzKztKdKeV2 <br />qh = 16.7 psf <br />p = 12.191 *(GCp) <br />FIGURE 30.3-2E Components & Cladding h<= 60 ft: External Pressure Coefficients, (GCp), for <br />Enclosed and Partially Enclosed Buildings - Hip roofs 7<=20deg (Roof) <br />FIGURE 30.3-2F Components & Cladding h<= 60 ft: External Pressure Coefficients, (GCp), for <br />Enclosed and Partially Enclosed Buildings - Hip roofs 7<=20deg (Overhang) <br />ASCE 7-16 <br />1 <br />1043 W Fairbrook <br />Ln05/19/23