Laserfiche WebLink
STRING 1: (8x) Longi LR4-60HPB-360M PV <br />MODULES <br />WITH 8 S440 SE POWER OPTIMIZERS <br />1 <br />1 <br />JUNCTION BOX <br />- NEMA 3R <br />AS REQUIRED <br />2 <br />3+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />STRING 2: (9x) Longi LR4-60HPB-360M PV <br />MODULES <br />WITH 9 S440 SE POWER OPTIMIZERS <br />921 <br />821 <br />INVERTER <br />SOLAREDGE SE5000H-US <br />NON-RGM <br />WITH DC DISCONNECT <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH RAPID <br />SHUTDOWN PER NEC 690.12 <br />DC AC <br />METER NUMBER: <br />222013-174014 <br />MAIN (E) 100A <br />(N)100A <br />M <br />BI-DIRECTIONAL <br />UTILITY METER <br />1PH/240V <br />SOLAR BREAKER LOCATED <br />AT THE FURTHEST END OF <br />BUS BAR FROM THE MAIN <br />BREAKER <br />(E) 100A/100A MAIN <br />SERVICE PANEL <br />240/120v 1-PH, 3-W <br />MAIN BONDING JUMPER <br />TO UTILITY GRID <br />(Overhead) <br />(N) 30A <br />(N) 200A SUB PANEL <br />120/240V <br />NEMA 3R UL LISTED <br />4 <br />(E) GROUNDING <br />ELECTRODE <br />(COPPER) <br />GROUND <br />ROD <br />POINT OF INTERCONNECTION <br />LOAD SIDE 705.12(B)(3)(2) <br />MAX BREAKER CALC.: <br />200A X 1.2 - 100A = 140A <br />DO NOT INSTALL ANY <br />ADDITIONAL BREAKERS IN <br />THIS PANEL <br />WARNING <br />MAIN SERVICE PANEL COMPLIES <br />WITH NEC 705.12(B)(3)(3) <br />RELOCATING ALL THE (E) LOADS <br />TO THE (N) SUB PANEL <br />AFCI BREAKERS <br />REQUIRED WHERE <br />CIRCUITS EXTEND <br />MORE THAN 6FT <br />CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS <br />ID CONDUCTOR CONDUIT CURRENT-CARRYING <br />CONDUCTORS IN CONDUIT EGC TEMP. CORR. FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING <br />1 <br />2 <br />3 <br />#10 PV Wire, in open air 3/4" EMT N/A #6 51 15 18.75 40 38.4 90 <br />#10 THWN-2, in conduit 3/4" EMT 4 #8 51 15 18.75 40 38.4 75 <br />#10 THWN-2, in conduit 3/4" EMT 3 #8 32 21 26 40 38.4 75 <br />4 #3 THWN, in conduit 1 1 <br />4" EMT 3 #6 32 130 122.2 75 <br />ASHRAE EXTREME LOW <br />DESIGN TEMPERATURES <br />ASHRAE 2% HIGH <br />32°C <br />32°C <br />INVERTER 1 SPECS <br />SOLAREDGE 5000H-US_Non-RGM <br />AC VOLTAGE (V) <br />240 <br />GROUND <br />0.99 <br />MAX OCPD (A) <br />30 <br />RATED POWER (W) <br />5000 <br />MAX OUTPUT (A) <br />21 <br />MAX INPUT (A) <br />14 <br />MAX INPUT (V) <br />480 <br />EFFICIENCY (CEC) <br />0.99 <br />POWERBOX MAX OUTPUT CURRENT <br />OPTIMIZERS IN SERIES <br />NOMINAL STRING VOLTAGE <br />ARRAY OPERATING CURRENT <br />STRING DETAILS <br />INVERTER 1 <br />STRING CALCULATIONS <br />STRING 1 STRING 2 <br />15A <br />8 <br />380V <br />21A <br />15A <br />9 <br />380V <br />21A <br />SYSTEM SUMMARY <br />ARRAY STC POWER <br />6120W <br />ARRAY PTC POWER <br />5718.8W <br />MAX AC CURRENT <br />21A <br />MAX AC POWER <br />5000W <br />INVERTER 1MODULE SPECS <br />Longi LR4-60HPB-360M <br />PMAX (W) <br />360 <br />PTC (W) <br />336.4 <br />ISC (A) <br />11.33 <br />IMP (A) <br />10.35 <br />VOC (V) <br />40.8 <br />VMP (V) <br />34.8 <br />TEMP. COEFF. OF VOC <br />-0.122 <br />POWER <br />OPTIMIZERS <br />RATED INPUT (W) <br />MAX INPUT ISC (A) <br />WEIGHTED EFFICIENCY <br />MAX OUTPUT(A) <br />MAX DC (V) <br />SOLAREDGE S440 Optimizer <br />440 <br />15 <br />98.6 <br />15 <br />60 <br />Nathan Draeger <br />DESIGNER: <br />DESIGN MGR: <br />Paul Kelvin Macavinta <br />NEW PV SYSTEM: 6,120 DC / 5000 AC <br />Heather Earnest <br />1029 W Orange Rd, Santa Ana, CA 92706 <br />APN: 00224333 <br />6/20/2023 <br />DATE:TIME: <br />07:55 AM <br />REVISION:DATE:DESCRIPTION: <br />DRAWING TITLE: <br />DRAWING PAGE: <br />SCALE: <br />LINE DIAGRAM & <br />DESIGN TABLES <br />P6 <br />JURISDICTION STAMPS: <br />EQUIPMENT SPECS <br />NOTES: <br />BETTER EARTH ELECTRIC INC. <br />16720 MARQUARDT AVE CERRITOS <br />CERRITOS, CA 90703 <br />PHONE #: (888) 373-9379 <br />LIC #: C10-1024460 <br />1029 W West <br />Orange Rd07/11/23