My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1123 S Magnolia Ave Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Magnolia Ave
>
1123 S Magnolia Ave Unit# 2
>
1123 S Magnolia Ave Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:18:31 PM
Creation date
6/1/2025 11:56:23 AM
Metadata
Fields
Template:
Plan
Permit Number
102120229
Full Address
1123 S Magnolia Ave Unit# 2
Document Relationships
102120229 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Magnolia Ave\1123 S Magnolia Ave Unit# 2
Text box
ID:
1
Creator:
Import Agent
Created:
6/1/2025 11:56 AM
Modified:
5/30/2025 11:56 AM
Text:
Type 2 Holdown Anchor
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Company:Date:10/5/2022 <br />Engineer:Page:1/5 <br />Project: <br />Address: <br />Phone: <br />E-mail: <br />Anchor Designer™ <br />Software <br />Version 3.2.2311.2 <br />1.Project information <br />Project description: <br />Location: <br />Fastening description: <br />2. Input Data & Anchor Parameters <br />General <br />Design method:ACI 318-14 <br />Units: Imperial units <br />Anchor Information: <br />Anchor type: Bonded anchor <br />Material: F1554 Grade 55 <br />Diameter (inch): 0.375 <br />Effective Embedment depth, hef (inch): 7.500 <br />Code report: ICC-ES ESR-4057 <br />Anchor category: - <br />Anchor ductility: Yes <br />hmin (inch): 8.75 <br />cac (inch): 19.72 <br />Cmin (inch): 1.75 <br />Smin (inch): 1.00 <br />Base Material <br />Concrete: Normal-weight <br />Concrete thickness, h (inch): 12.00 <br />State: Cracked <br />Compressive strength, f’c (psi): 3000 <br />Ψc,V: 1.0 <br />Reinforcement condition: A tension, A shear <br />Supplemental edge reinforcement: Not applicable <br />Reinforcement provided at corners: No <br />Ignore concrete breakout in tension: No <br />Ignore concrete breakout in shear: No <br />Hole condition: Dry concrete <br />Inspection: Continuous <br />Temperature range, Short/Long: 150/110°F <br />Reduced installation torque (for AT-3G): Not applicable <br />Ignore 6do requirement: Not applicable <br />Build-up grout pad: No <br />Recommended Anchor <br />Anchor Name: SET-3G™ - SET-3G w/ 3/8"Ø F1554 Gr. 55 <br />Code Report: ICC-ES ESR-4057 <br />Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. <br />Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com <br />ADU 1123 Magnolia Ave. <br />Proj. No. 16113.00 09/30/24 <br />49 <br />1123 S Magnolia Ave <br />Unit# 22/19/2025
The URL can be used to link to this page
Your browser does not support the video tag.