ELECTRICAL: <br /> 1. ALL ELECTRICAL WORK TO CONFORM WITH UTILITY COMPANY REQUIREMENTS AND LOCAL CODES. <br /> 2. ELECTRICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS. <br /> 3. CONTRACTOR SHALL INSPECT EXISTING SERVICE PRIOR TO SUBMITTING BID TO INSURE ADEQUACY <br /> FOR NEW EQUIPMENT AND ELECTRICAL. A NEW SERVICE OF PROPER SIZE SHALL BE PART OF THE\ <br /> CONTRACT IF REQUIRED. <br />4. FIXTURES TO BE SELECTED BY OWNER AND INSTALLED BY ELECTRICIAN <br />5. PROVIDE ALL BATHROOM AND EXTERIOR OUTLETS ON GROUND FAULT DETECTOR CIRCUITS. <br />HEATING:(CONTINUED) <br /> 6)ALL EXHAUST SYSTEMS SHALL HAVE DAMPERS. <br /> 7)PROVIDE SETBACK THERMOSTAT ON ALL HEATING OR COOLING SYSTEMS EXCEPT <br /> HEAT PUMPS. <br />B)FAN SYSTEMS: <br /> 1) FAN SYSTEMS EXHAUSTING AIR FROM THE BUILDING TO THE OUTSIDE SHALL BE <br /> PROVIDED BACK-DRAFT DAMPERS INSTALLED TO PREVENT AIR LEAKAGE WHEN THE <br /> FAN IS NOT OPERATING. <br />C) INSTALLATION AND WORKMANSHIP: <br /> 1) ALL WORK SHALL BE PERFORMED IN THE BEST PRACTICE OF THE TRADE AND <br /> CONFORMING TO ALL APPLICABLE CODES. REGISTERS SHALL BE LOCATED IN <br /> ALL ROOMS. SEE DRAWINGS FOR LOCATIONS. UPON COMPLETION, THIS CONTRACTOR <br /> SHALL CHECK OUT AND BALANCE THE SYSTEM. <br />D) HEATING AND VENTILATING CONTRACTOR SHALL FURNISH ALL MECHANICAL DRAWINGS <br /> FOR CONSTRUCTION AND PERMITS. ALL. WORK TO COMMON WITH THE LATEST CODE <br /> AND SAFETY REGULATIONS. <br />OCCUPANCY LIFE SAFETY: <br />1. PROVIDE 110V SMOKE ALARMS(DETECTORS) WITH BATTERY BACKUP IN ALL <br /> SLEEPING ROOMS , HALLWAYS AND ROOMS LEADING TO THE ROOMS. THE DETECTOR <br /> SHALL SOUND ALARM AUDIBLE IN ALL SLEEPING ROOMS OF THE DWELLING. <br />SECURITY: <br />1. SWINGING DOORS: <br /> A)DOOR STOPS OF IN-SWINGING DOORS SHALL BE OF ONE PIECE CONSTRUCTION <br /> WITH THE JAMS OR JOINED BY RABBET TO THE JAMBS. <br /> B)ALL PIN TYPE HINGES WHICH ARE ACCESSIBLE FROM OUTSIDE THE SECURED AREA <br /> WHEN THE DOOR IS CLOSED SHALL HAVE NON-REMOVABLE HINGE PINS. IN <br /> ADDITION, THEY SHALL HAVE ¼" STEEL JAM STUD WITH ¼" MINIMUM PROJECTION <br /> UNLESS THE HINGES ARE SHAPED TO PREVENT REMOVAL OF THE DOOR IF THE <br /> PINS ARE REMOVED. <br /> C)THE STRIKE PLATE FOR LATCHES AND THE BOLDING DEVICE FOR PROJECTING <br /> DEADBOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAM AND WALL <br /> FRAMING WITH 2 ½" LONG SCREWS. <br /> D)DEADBOLTS SHALL HAVE HARDENED INSERTS, MIN 1" THROW EMBEDMENT 5/8". <br /> E)WOOD FLUSH DOORS SHALL BE IN MIN 1 3/8" THICK, SOLID CORE, PANEL TYPE <br /> MIN PANEL THICKNESS 9/16. MAX 300 SQ. INCHES IN AREA. <br /> F)GLASS DOORS SHALL HAVE FULLY TEMPERED GLASS. <br />2.CYLINDER GUARDS HALL BE INSTALLED ON ALL CYLINDER LOCKS WHENEVER THE <br /> CYLINDER PROJECTS BEYOND THE FACE OF THE DOOR OR IS OTHERWISE EXPOSED <br /> TO GRIPPING TOOLS. <br />3.SLIDING GLASS DOORS AND WINDOWS SHALL BE ALE TO RESIST THE TESTS SET <br /> FORTH IN 91.6731 AND 91.6732 OF THE BUILDING CODE. <br />4.SLIDING GLASS DOORS AND WINDOWS SHALL BE PROVIDED WITH A DEVICE IN THE <br /> UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND REMOVING OF <br /> THE PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION. <br />5.PROVIDE HARDENED LOCK AND LATCH ON OVERHEAD GARAGE DOORS OVER 9'0" IN <br /> LENGTH. <br />6.GLAZED OPENINGS WITHIN 40" OF THE DOOR LOCK WHEN THE DOOR IS IN THE <br /> CLOSED POSITION SHALL BE FULLY TEMPERED GLASS. <br />7.USE DEAD LOCKING LATCH KEY OPERATED LOCKS ON EXTERIOR; LOCKS OPEN ABLE <br /> WITHOUT KEY OR SPECIAL KNOWLEDGE OR EFFORT ON INTERIOR. <br />8.INACTIVE LEAF OF ALL EXTERIOR DOUBLE DOORS SHALL HAVE APPROVED SLIDE <br /> BOLD LOCKING DEVICE AT TOP AND BOTTOM. <br />9.PROVIDE 110V SMOKE ALARMS(DETECTORS) WITH BATTERY BACKUP IN ALL SLEEPING <br /> ROOMS , HALLWAYS AND ROOMS LEADING TO THE ROOMS. THE DETECTOR SHALL <br /> SOUND ALARM AUDIBLE IN ALL SLEEPING ROOMS OF THE DWELLING. <br /> 3)STAIN SHALL BE MONSANTO CHEMICAL OR OLYMPIC. <br /> 4)ALL WORK TO BE IN ACCORDANCE WITH BEST PRACTICES OF THE TRADE. <br /> E. MISCELLANEOUS: REFER TO PLANS FOR SPECIFIC MATERIALS AND FINISHES. <br />ENERGY:(CONTINED) <br />7)THE BUILDER SHALL PROVIDE THE ORIGINAL OCCUPANT A LIST OF THE <br /> HEATING, COOLING, WATER HEATING, LIGHTING SYSTEMS AND <br /> CONSERVATION OR SOLAR DEVICES INSTALLED IN THE BUILDING AND <br /> INSTRUCTIONS ON HOW TO USE THEM EFFICIENTLY. <br />8)A MAINTENANCE LABEL SHALL BE AFFIXED TO ALL EQUIPMENT REQUIRING <br /> PREVENTIVE MAINTENANCE, AND A COPY OF THE MAINTENANCE <br /> INSTRUCTIONS SHALL BE PROVIDED FOR THE OWNER'S USE. <br />9)ALL INSULTING MATERIALS SHALL BE CERTIFIED BY THE MANUFACTURER <br /> AS COMPLYING WITH CALIFORNIA QUALITY STANDARDS FOR INSULATION. <br />A. HEATING AND COOLING <br /> 1) IF HEATING IS TO BE ACCOMPLISHED BY EXTENDING DUCTS FROM AN <br /> EXISTING FORCED AIR UNIT, NO EQUIPMENT SIZING WILL BE REQUIRED. <br /> 2)IF NEW HEATING EQUIPMENT IS NEEDED, HEAT LOSS CALCULATING <br /> MUST BE PREPARED TO SIZE SYSTEM. <br /> 3)NEW UNIT MUST BE EQUIPPED WITH A PROGRAMMABLE HIGH SET-BACK <br /> THERMOSTAT. <br /> 4)DUCTS SHALL BE CONSTRUCTED, INSTALLED AND INSULATED <br /> ACCORDING TO CHAPTER 10 OF THE UNIFORM MECHANICAL CODE ALL <br /> PARTS OF THE DUCT SYSTEM SHALL BE TIGHTLY SEALED WITH MASTIC <br /> OR TAPE. <br /> 5)THE FOLLOWING OPENINGS IN THE BUILDING ENVELOPE SHALL BE <br /> CAULKED OR OTHERWISE SEALED TO LIMIT INFILTRATION: <br /> A) EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, BETWEEN <br /> WALL SOLE PLATES AND FLOORS, AND BETWEEN EXTERIOR WALL <br /> PANELS. <br /> B) OPENINGS FOR PLUMBING, ELECTRICITY AND GAS LINES IN WALLS, <br /> CEILINGS, AND FLOORS. <br /> C) OPENINGS IN ATTIC FLOOR. <br /> D) ALL OTHER SUCH OPENING IN BUILDING ENVELOPE. <br /> 6)STORAGE TYPE WATER HEATERS AND STORAGE BACK-UP TANKS FOR <br /> SOLAR WATER HEATING SYSTEMS SHALL BE EXTERNALLY WRAPPED <br /> WITH INSULATION OR R-12 OR GREATER. <br /> 7)PIPING IN UNCONDITIONED SPACE LEADING TO AND FROM WATER <br /> HEATERS SHALL BE WRAPPED WITH INSULATION R-3 FOR 5' OF PIPE <br /> NEXT TO WATER HEATER. <br /> 8)RECIRCULATING HOT WATER PIPING IN UNHEATED SPACES SHALL BE <br /> INSULATED. <br /> 9)GAS FIRED COOKING APPLIANCES, SHOWER HEADS AND FAUCETS SHALL <br /> COMPLY WITH THE APPLIANCE EFFICIENCY STANDARDS. <br /> B.WATER HEATING: <br /> 1) INSULATE TANK WITH R-12 EXTERNAL BLANKET. <br /> 2) INSULATE INLET AND OUTLET PIPES WITH R-3 FIRST 5 FEET. <br /> 3) SHOW MAKE, MODEL, AND SIZE OF WATER HEATER ON PLANS. <br /> D. LIGHTING: <br /> 1)GENERAL LIGHTING IN KITCHENS AND BATHS SHALL HAVE AN <br /> EFFICIENCY OF NOT LESS THAN 25 LUMENS PER WATT, EXCEPT THAT <br /> LUMINARIES USED AS THE ONLY LIGHTING IN BATHS ARE EXEMPT FROM <br /> THIS REQUIREMENT. <br />PLUMBING: <br /> 1. GENERAL: <br /> 1) PLATE STRAPS SHALL BE USED TO REPAIR STUDS, PLATES, AND <br /> TRIMMERS WHERE CUT OR DRILLED MORE THAN ONE-HALF THE DEPTH. <br /> 2)ALL PIPING THROUGH WALLS SHALL BE FILLED WITH MASTIC AND <br /> COVERED WITH ESCUTCHEONS PLATES. <br /> 3)PLUMBING VENTS SHALL NOT BE LOCATED CLOSER THAN <br /> 10 FEET FROM ANY PROPERTY LINE. <br /> 4) ALL METALLIC PIPING UNDER SLAB SHALL BE SLEEVED. <br /> 5)ALL WATER CLOSETS SHALL BE 1.28 GALLONS PER FLUSH MAXIMUM. <br /> 6)ALL SINKS AND LAVATORIES SHALL BE 1.5 GALLONS PER MINUTE. <br /> 7) ALL SHOWERS HEADS SHALL BE 2.0 GALLONS PER MINUTE. <br /> 8)ALL HOSE BIBS SHALL HAVE NON-REMOVABLE TYPE LISTED <br /> BACK FLOW PREVENTION DEVICES WITHOUT ATTACHED HOSE <br /> 9)NO CELLULAR CORE ABS-DWV WILL BE USED. <br />2.WATER PIPING: <br /> A)MATERIALS: <br /> 1)COPPER TUBE FOR WATER PIPING SHALL HAVE A WRIGHT OF NOT LESS <br /> THAN THAT OF COPPER WATER TUBE TYPE L. EXCEPTION: TYPE W <br /> COPPER TUBING MAY BE USE FOR WATER PIPING WHEN PIPING IS ABOVE <br /> GROUND, AND THE NORMAL MAXIMUM PRESSURE DOES NOT EXCEED 100 <br /> POUNDS, AND THE WORKING TEMPERATURE DOES NOT EXCEED 210 F. <br /> B)WATER HEATER: <br /> 1)WATER HEATER SHALL BE ANCHORED OR STRAPPED. STRAPPING SHALL <br /> BE AT A POINT WITHIN UPPER AND LOWER ONE THIRD (1/3) OF ITS <br /> DIMENSIONS. <br /> 2)WATER HEATER INSULATION BLANKET (R-16 OR GREATER) REQUIRED AND <br /> FIRST FIVE FEET OF PIPES CLOSETS TO TANK TO BE INSULATED (R-3). <br /> 3)WATER HEATER WILL HAVE TEMPERATURE AND PRESSURE RELIEF VALVE <br /> THAT WILL VENT TO EXTERIOR OUTLET SHALL NOT BE HIGHER THE 24" <br /> OR LOWER THEN 6" ABOVE GRADE. <br />3.GAS PIPING: <br /> A)MATERIALS: <br /> 1)ALL PIPE USED FOR THE INSTALLATION OF ANY GAS PIPING SHALL BE <br /> STANDARD WEIGHT WROUGHT IRON OR STEEL(GALVANIZED OR BLACK). <br /> YELLOW BRASS (CONTAINING NOT MORE THAN SEVENTY-FIVE (75) <br /> PERCENT COPPER), OR INTERNALLY TINNED OR EQUIVALENTLY TREATED <br /> COPPER OF IRON PIPE SIZE. <br /> 2)ALL FITTINGS USED IN CONNECTION WITH THE ABOVE PIPING SHALL BE <br /> OF MALLEABLE IRON OR YELLOW BRASS (CONTAINING NOT MORE THAN <br /> SEVENTY-FIVE (75) PERCENT COPPER. <br /> 3)GAS COOKING APPLIANCES TO BE EQUIPPED WITH INTERMITTENT IGNITION <br /> DEVICE. <br /> 4)MASONRY AND FACTORY-BUILT FIREPLACES SHALL HAVE: <br /> a)TIGHT FITTING, CLOSABLE METAL OR GLASS DOOR. <br /> b)OUTSIDE AIR INTAKE WITH DAMPER AND CONTROL. <br /> c)FLUE DAMPER AND CONTROL. <br /> d)NO CONTINUOUS BURNING GAS PILOT ALLOWED. <br /> 4.WASTE PIPING: <br /> MATERIALS: <br /> 1) ALL WASTE PIPING WHICH PENETRATES WALLS WITH (L) HOUR FIRE <br /> RESISTIVE MATERIALS APPLIED SHALL BE CAST IRON OR OTHER <br /> NONCOMBUSTIBLE PIPING MATERIAL APPROVED BY THE UNIFORM BUILDING <br /> CODE APPLICABLE EDITION, STATE AND LOCAL CODES. <br /> 2)RAPID FIT WASTE AND OVERFLOW FITTINGS SHALL BE USE IN LIEU OF <br /> ACCESS PANEL AS PER I.A.P.M.O. FILE NO. 966. <br />GENERAL REQUIREMENTS: <br /> 1. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE LATEST EDITION <br /> OF THE california BUILDING CODE AND SUCH OTHER REGULATING AGENCIES <br /> EXERCISING AUTHORITY OVER ANY PORTION OF THE WORK. <br /> 2. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND <br /> CONDITIONS AT THE SITE AND SHALL NOTIFY THE ARCHITECT OR DESIGNER OF <br /> DISCREPANCIES BETWEEN THE ACTUAL CONDITIONS AND INFORMATION SHOWN <br /> ON DRAWINGS BEFORE PROCEEDING WITH THE WORK. <br /> 3. CONTRACTOR SHALL CONSULT ALL REPRESENTATIVES OF CITY, GAS,LIGHT, WATER, <br /> POWER AND PHONE COMPANIES CONCERNING AVAILABLE FACILITIES, REPORT <br /> COMMENCING WORK OR CONNECTING FACILITIES. <br /> 4. THE CONTRACT DOCUMENTS CONSISTS OF THE AGREEMENT, THE GENERAL <br /> CONDITIONS OF THE CONTRACT, THE DRAWINGS AND SPECIFICATIONS, INCLUDING <br /> ALL MODIFICATIONS THEREOF INCORPORATED IN THE DOCUMENTS BEFORE <br /> EXECUTION. <br /> 5. THE SUB-LETTING OF THE WORK BY THE CONTRACTOR SHALL NOT IN ANY WAY <br /> RELIEVE HIM OF ANY RESPONSIBILITY OR OBLIGATION TO THE OWNER, ARCHITECT <br /> OR DESIGNER, OR THE CONTRACT. <br /> 6. CONSTRUCTION AND STORAGE OPERATIONS SHALL BE KEPT WITHIN THE AREAS <br /> DESIGNED BY THE OWNER. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN <br /> OTHER AREAS. <br /> 7. THE GENERAL CONTRACTOR AND EACH SUB-CONTRACTOR SHALL CARRY <br /> INSURANCE TO COVER THE PUBLIC AND WORKMAN'S COMPENSATION DURING THE <br /> ENTIRE JOB. CERTIFICATE OF SAME SHALL BE FILED WITH THE OWNER. <br /> 8. THE CONTRACTOR SHALL EXECUTE THE WORK WITH THE UTMOST DISPATCH. <br /> BAILING IN THIS, OWNER SHALL HAVE THE RIGHT, UPON FIVE DAYS WRITTEN <br /> NOTICE, TO PURCHASE MATERIALS AND TO EMPLOY MEN TO EXECUTE THE WORK, <br /> AND THE COST OF SAID MATERIALS AND LABOR SHALL BE DONE BY THE <br /> CONTRACTOR. <br /> 9. CLEAN UP; <br /> a) PERIODIC CLEAN-UP: EMPTY ALL REFUSE BARRELS AND CANS AND REMOVE <br /> RUBBISH AND DEBRIS FROM THE SITE AT LEAST ONCE EVERY WEEK DURING <br /> THE CONSTRUCTION PERIOD. <br /> b) COMPLETION: UPON COMPLETION OF THE WORK, REMOVE THE RUBBISH FROM <br /> OR ABOUT THE BUILDING AS WELL AS ALL TOOLS, SCAFFOLDING, AND SURPLUS <br /> MATERIALS. IN CASE OF DISPUTE BETWEEN THE CONTRACTOR AND OTHER <br /> CONTRACTORS, AS TO RESPONSIBILITY FOR REMOVAL OR RUBBISH, ETC., OR IN <br /> CASE RUBBISH, ETC., IS NOT PROMPTLY REMOVED. THE OWNER MAY REMOVE <br /> RUBBISH, ETC., AND CHARGE THE COST TO THE CONTRACTOR. <br /> c) FINAL CLEANING: IMMEDIATELY PRIOR TO FINAL INSPECTION, GIVE THE ENTIRE <br /> BUILDING A FINAL CLEANING, INCLUDING REMOVAL OF THE PROTECTIVE <br /> COVERING MATERIALS APPLIED TO ALUMINUM AND OTHER MATERIALS, REMOVAL <br /> OF LABELS, WASHING GLASS, FLOORS AND TILE SURFACES, WAXING RESILIENT <br /> FLOORING, CLEANING AND POLISHING PLUMBING FIXTURES, HARDWARE, AND <br /> OTHER METAL, CLEANING EQUIPMENT, AND REMOVAL OF ALL TOOLS, EQUIPMENT, <br /> DEBRIS, TEMPORARY FACILITIES, ETC. AS REQUIRED TO PREPARE THE BUILDING <br /> FOR OCCUPANCY. <br /> 10.ALL CONDITIONS NOTED AS EXISTING OR SHOWN AS EXISTING ARE BASED ON THE <br /> BEST INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THE DRAWINGS. <br /> NO WARRANTY IS IMPLIED AS TO THE ACCURACY OF THE ITEMS REFERRED AS <br /> EXISTING. <br />SITE WORK: <br />1.THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN THE DEPTH INTO WHICH A <br />PERSON IS REQUIRED TO DESCEND. <br />2.UNDERGROUND UTILITIES: THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL <br />UNDERGROUND UTILITIES PRIOR TO COMMENCING DEMOLITION, EXCAVATIONS, OR GRADING. <br />DISCONNECT AND CAP OR PROTECT AS REQUIRED. <br />3.GRADE SITE TO ELEVATIONS FROM ON GRADING PLAN. CUT OR FILL AS REQUIRED. ALL <br />PORTIONS OF THE SITE, INCLUDING YARDS, ARRAYS, COURTYARDS AND PASSAGEWAYS SHALL BE <br />PROPERLY GRADED SO THAT WATER DRAINS AWAY FROM THE BUILDINGS. <br />4.ALL EXCESS DIRT AND TRASH ARE TO BE REMOVED FROM SITE. <br />5.ALL GRADING TO BE PERFORMED I ACCORDANCE WITH ALL APPLICABLE CODES AND LOCAL OR <br />ORDINANCES AND THE APPROVED SOILS AND/OR GEOLOGY REPORT. <br />6.UPON COMPLETION ALL WOOD, PLASTER, OR OTHER DEBRIS SHALL BE CLEARED FROM THE SITE. <br />GRADING SHALL BE PREFORMED SO THAT ALL SURFACE WATER DRAINS RAPIDLY AWAY FROM THE <br />STRUCTURE AND THEN PROPERLY TO THE DRAINAGE DEVICES OR THE STREET. <br />FOUNDATIONS: <br /> 1.FOUNDATION SHALL BEAR AS DETAILED ON THE PLANS AND/OR INDICATED IN THE <br /> SOIL REPORT. <br /> 2.DESIGN SOIL BEARING PRESSURE INDICATED IN THE STRUCTURAL CALCS. <br /> 3.FOOTING ELEVATIONS SHOWN ON THE PLANS ARE FOR ESTIMATING PURPOSES ONLY <br /> AND SHALL BE VERIFIED IN THE FIELD. <br /> 4.EXCAVATIONS ADJACENT TO EXISTING BUILDINGS OR WALLS SHALL NOT EXTEND <br /> BELOW AN ANGLE OF 45 DEGREES FROM THE BOTTOMS OF THE FOOTINGS OF <br /> THESE ADJACENT STRUCTURES, OR THE CONTRACTOR SHALL PROVIDE ADEQUATE <br /> SHORING FOR THE EXCAVATIONS. <br /> 5.WHERE EXISTING FOOTINGS, CONCRETE SLABS, PIPES, UTILITIES OR OTHER BURIED <br /> ITEMS ARE REMOVED, WHERE NEW SLABS OR FOOTINGS ARE TO BE LOCATED, <br /> ALL EXISTING LOOSE SOIL SHALL BE REMOVED AND RECOMPUTED TO A MINIMUM <br /> OF 90% OF MAXIMUM DENSITY. <br /> 6.ALL FILL SHALL BE COMPACTED TO A MINIMUM OF 90% OF MAXIMUM DENSITY IN <br /> ACCORDANCE WITH ASTM D-1557. FILL SHALL BE PLACED UNDER THE SUPERVISION <br /> OF, AND TESTED AND CERTIFIED BY, AN APPROVED SOIL'S ENGINEER. <br /> 7.ANCHOR BOLTS SHALL BE 5/8" DIAMETER X 12" WITH 9" MIN. EMBEDMENT, <br /> SPACING 6' MAXIMUM UNLESS NOTED OTHERWISE. SEE PLANS FOR SPACING. <br /> INSTALL A MINIMUM 2 BOLTS IN EACH PIECE OF SILL PLATE AND MINIMUM OF 12" <br /> FROM SILL ENDS. USE ONE PLATE WASHER: 0.229"X 3"X 3" <br /> 8.HOLD DOWN HARDWARE MUST BE SECURED PRIOR TO THE FOUNDATION INSPECTION <br />MASONRY:(Continued) <br />1.NO. S SIEVE AND ALL PASSING 3/8 INCH SIEVE. <br />2.CONCRETE BLOCK SHALL BE PLACED IN ACCORDANCE WITH CHAPTER 24 OF THE BUILDING CODE. <br />3.VERTICAL STEEL: SET AND BRACE BEFORE PROCEEDING WITH MASONRY WORK. <br />10.LAPS: 40 DIAMS. AT SPLICES, CORNERS AND INTERSECTIONS. <br />11.CONTINUOUS INSPECTION: NOT REQUIRED <br />12.REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO A.S.T.M. DESCRIPTION A15 <br />AND A305EXCEPT THAT ¼" TIES MAY BE PLAIN BARS. WIRE REINFORCEMENT SHALL CONFORM TO <br />A.S.T.M DESIGNATION A82. <br />13.WORKMANSHIP: CONSTRUCTION SHALL BE OF THE HIGHEST QUALITY WORKMANSHIP AND ALL <br />WALLS SHALL BE LAID TRUE AND PLUMB. PROVISIONS SHALL BE ARRANGED FOR ALL ADJOINING <br />CONSTRUCTION. ALL WALLS TO HAVE FLUSH JOINTS READY TO RECEIVE PLASTER OR <br />WATERPROOFING. <br />14.TOOL ALL JOINTS, UNLESS INDICATED ON DRAWINGS OTHERWISE. <br />CONCRETE: <br />1.ALL CONCRETE SHALL BE MADE WITH STONE AGGREGATE AND SHALL ATTAIN A MINIMUM <br />COMPRESSIVE STRENGTH AT 28 DAYS OF 2500 PSI. <br />2.MAXIMUM CONCRETE SLUMP SHALL BE 3" <br />3.CEMENT FOR CONCRETE, MORTAR, AND GROUT SHALL BE TYPE I OR II CONFIRMING AT ASTM <br />C-150. AGGREGATE SHALL CONFORM TO ASTM C-33 <br />4.NO PIPES OR DUCTS, OTHER THAN CONDUIT, SHALL BE PLACED IN STRUCTURAL CONCRETE UNLESS <br />SPECIFICALLY SHOWN. ALUMINUM CONDUIT SHALL NOT BE USED. <br />5.VERIFY WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWING LOCATION OF ALL ITEMS IN <br />OR ATTACHED TO CONCRETE. <br />6.DRYPACK SHALL BE 1:3 CEMENT AND SAND MIX. <br />ASPHALTIC PAVING: <br />1.SUBGRADE: SCARIFY & COMPACT TO 90%. FILL OR CUT AS REQUIRED. REMOVE DEPRESSIONS <br />AND HIGH POINTS AND BRING ENTIRE AREA TO SMOOTH PLANE. APPLY SOIL POISONING AGENT. <br />2.BASE AGGREGATE: 4" THICK ASE COURSE OF ¾MAXIMUM TYPE A MEDIUM AGGREGATE, 1" THICK <br />SURFACING COURSE OF 3/8" MAXIMUM TYPE A MEDIUM AGGREGATE, FOG SEAL. PLACE, SPREAD <br />AND COMPACT IN ONE CONTINUOUS OPERATION. BARRICADE UNTIL CURED. <br />3.OUTLINES OF ALL PAVING SHALL BE 1" X 3" HEADER BOARDS. <br />METAL: <br /> A. STRUCTURAL STEEL. <br /> 1.STRUCTURAL STEEL ROLLED SECTIONS AND PLATE USED IN THE WORK SHALL <br /> CONFORM TO ASTM A36. <br /> 2.PIPE COLUMNS SHALL BE WELDED SEAMLESS PIPE CONFORMING TO ASTM A53 <br /> FOR GRADE "B" PIPE. <br /> 3.SQUARE OR RECTANGULAR TUBES SHALL BE WELDED SEAMLESS SECTIONS MADE <br /> OF STEEL CONFORMING TO ASTM A36. <br /> 4.ALL FABRICATION SHALL BE DONE IN THE SHOP OF FABRICATOR LICENSED BY <br /> THE BUILDING OFFICIAL OR UNDER THE CONTINUOUS INSPECTION OF A <br /> REGISTERED DEPUTY INSPECTOR LICENSED BY THE SAME BODY. <br /> 5.BOLTED CONNECTIONS USED IN THE WORK SHALL CONSIST OF UNFINISHED BOLTS <br /> CONFORMING TO ASTM A307. <br /> 6.ALL WELDING SHALL CONFORM TO THE STANDARD CODE FOR ABC AND GAS <br /> WELDING OF THE AMERICAN WELDING SOCIETY. <br /> B. SHEET METAL <br /> 1.ALL FLASHING, COUNTER FLASHING, AND COPING WHEN OF METAL SHALL BE OF <br /> NOT LESS THAN NO. 26 U.S. GAUGE CORROSION-RESISTANT METAL. FLASH ALL <br /> PENETRATIONS. <br /> 2.FLASH AND COUNTER FLASH AT ALL ROOF TO WALL CONDITIONS. G.I. FLASH <br /> AND CAULK WOOD BREAMS AND OUTLOOKERS PROJECTING THROUGH EXTERIOR <br /> WALLS OR ROOF SURFACES. <br /> 3.NAILS SHALL BE LONG ENOUGH TO GIVE A MINIMUM PENETRATIONS OF ¾INTO <br /> WOOD,1" INTO MAILING CONCRETE. <br /> 4.SCREWS TO BE PLATED WITH ZINC OR CADMIUM INTO METAL AND EITHER 1" <br /> SLATING NAILS NOT SMALLER THAN NO. 6 BY 1" SCREWS INTO LEAD PLUGS. <br />MOISTURE PROTECTION: <br /> 1.WEATHER-STRIP ALL DOORS AND WINDOWS EXPOSED TO THE EXTERIOR AL DOORS <br /> AND WINDOWS TO BE CERTIFIED. <br /> 2.METAL PLASTER GROUND WITH WEEP HOLES SHALL BE INSTALLED AT THE <br /> EXTERIOR OF THE BUILDING, AT THE INTERSECTION OF THE MUDSILL AND THE <br /> CONCRETE SLAB. SCREWED, TO BE 26 GAUGE CORROSION RESISTANT METAL <br /> WITH ¼" ROUND WEEP HOLES AT 3" O.C. <br /> 3.ALL JOINTS AND PENETRATIONS TO OUTSIDE TO BE CAULKED AND SEALED. <br /> 4.MOISTURE BARRIER: PROVIDE ONE (1) LAYER 15 POUND ASPHALT SATURATED <br /> FELT MINIMUM UNDER ALL EXTERIOR FINISHERS. <br /> 5.MATERIALS: ALL EXTERIOR MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF <br /> THE UNIFORM BUILDING CODE APPLICABLE EDITION, STATE AND LOCAL CODES. <br />INSULATION: <br /> 1. ALL EXTERIOR WALLS, WALLS BETWEEN LIVING SPACE AND UNHEATED GARAGE OR <br /> STORAGE ROOM, BETWEEN JAMBS AND FRAMING, CEILINGS WITH COLD AREAS <br /> ABOVE, ATTIC ACCESS PANEL, KNEE WALLS ADJACENT TO HEATED SPACE, <br /> BETWEEN COMBINATION RAFTER AND CEILING JOIST (LEAVE OPEN SPACE ABOVE <br /> FOR VENTILATION) TO HAVE A MINIMUM (BATT) INSULATION OF R-15WALLS, R-30 <br /> CEILINGS. <br /> 2.BUILDER AND INSULATION INSTALLER ARE TO PROVIDE A CERTIFICATE OF <br /> INSTALLATION AND POST IN THE BUILDING IN A CONSPICUOUS LOCATION. <br /> 3.INSTALLATION SHALL CONFORM TO TITLE 24 OF THE STATE OF CALIFORNIA <br /> ADMINISTRATIVE CODE AND SHALL BE CERTIFIED AS COMPLYING WITH TITLE 24 BY <br /> INSULATION INSTALLER. <br />CARPENTRY: <br /> 1. WOOD FRAMING: FRAMING REQUIREMENTS SUCH AS NAILING, LET-IN DIAGONAL <br /> BRACES, ETC., SHALL BE PER MINIMUM REQUIREMENTS OF THE APPLICABLE <br /> LOCAL CODE UNLESS GREATER REQUIREMENTS ARE INDICATED ON PLANS OR <br /> SPECIFICATIONS. <br /> 2. FRAMING LUMBER: FRAMING LUMBER SHALL BE DOUGLAS FIR LARGE, GRADE <br /> MARKED BY W.W.P.A. OR W.C.L.I.B. AS FOLLOWS, UNLESS OTHERWISE NOTED ON <br /> PLANS: <br /> VERTICAL FRAMING <br /> 2" X 4" & 4" X 4" ........................................STANDARD GRADE <br /> 2" X 6" AND LARGER .......................................NO. 2 GRADE <br /> 6" X 6" AND LARGER .......................................NO. 1 GRADE HORIZONTAL FRAMING <br /> 2" X & 4" X .....................................................NO. 2 GRADE <br /> 6" X AND LARGER.............................................NO. 1 GRADE <br /> 3. MOISTURE CONTENT: MOISTURE CONTENT OF DOUGLAS FIR FRAMING LUMBER <br /> SHALL NOT EXCEED 20% IN ADDITION, THE LUMBER SHALL BE AIR DRIED FOR 60 <br /> DAYS UNDER ADEQUATE COVER ON THE SITE,OR LUMBER MAY BE USED THAT <br /> HAS A MOISTURE CONTENT APPROXIMATELY EQUAL TO THAT WHICH WILL <br /> EVENTUALLY BE ATTAINED IN SERVICE. <br /> 4.PROTECTION AGAINST DECAY AND TERMITES: <br /> A) WOOD EMBEDDED IN THE GROUND OR IN DIRECT CONTACT WITH THE EARTH <br /> AND USED FOR THE SUPPORT OF PERMANENT STRUCTURES, SHALL BE TREATED <br /> WOOD. <br /> B) WOOD JOISTS OR THE BOTTOM OF WOOD FLOORS CLOSER THAN 18 INCHES, OR <br /> WOOD GIRDERS CLOSER THAN 12 INCHES TO THE GROUND UNDER FLOOR AREAS <br /> AND THEIR SUPPORTS, SHALL BE OF TREATED WOOD OR ALL HEARTWOOD OF <br /> APPROVED NATURALLY DURABLE SPECIES AS LISTED IN THE UNIFORM BUILDING <br /> CODE APPLICABLE EDITION. <br />5. EXTERIOR AND BEARING STUD WALL REQUIREMENTS: <br /> MAXIMUM HEIGHT: <br /> UP TO 10'..............................................................2X4 @ 16"OC <br /> UP TO 20'.............................................................2X6 @ 16"OC <br /> UP TO 22'..............................................................2X8 @ 16"OC <br /> UP TO 24'.....................................2X10 @ 16"OC OR 2X8 @ 8 <br />6. NAILING SCHEDULE: <br />NAILS <br />NAILING CONNECTION BOX OR COMMON <br />POST TO PIER PAD - TOP NAIL .....................3-16D OR 4-SD <br />GIRDER TO POST-TOE NAIL..........................316D OR 4-SD <br />JOIST TO SILL OR GIRDER-TOE NAIL.................3-8D <br />BRIDGING TO JOIST-TOE NAIL.......................2-8D <br />1 X 6 SUB-FLOOR TO JOIST-FACE NAIL................2-8D <br />PLYWOOD SUB-FLOOR TO JOIST-FACE NAIL..........8D-6"O.C. (U.N.O.) <br />2-INCH SUB-FLOOR TO JOIST OR GIRDER ............2-16D <br />PLATE TO JOIST OR BLOCKING.......................16D-16" O.C. <br />STUD TO PLATE-END NAIL...........................2-16D <br />STUD TO PLATE-TOE NAIL...........................3-16D OR 4-8D <br />TOP PLATES-SPIKE TOGETHER........................16D OR 16" O.C. <br /> -LAPS AND INTERSECTIONS..................2-16D (U.N.O.) <br />CEILING JOISTS TO PLATE TOE NAIL.................2-16D OR 3-8D <br /> -LAPS OVER PARTITIONS....................3-16D <br /> -TO PARALLEL ALTERNATE RAFTE.............3-16D <br />RAFTER TO PLATE - TOE NAIL.......................2-16D OR 3-8D <br />RAFTER TO RIDGE..................................2-16D OR 3-8D <br />CONTINUOUS 1-INCH BRACE TO STUD..................3-8D <br />2-INCH CUT - IN BRACE TO STUD....................2-16D <br />1X6 SHEATHING TO BEARING.........................2-8D <br />1X8 SHEATHING TO BEARING.........................3-8D <br />*PLYWOOD SHEATHING TO BEARING....................3D-6" O.C. (U.N.O.) <br />CORNER STUDS AND ANGLES..........................16D-24" O.C. <br />7. NAILS, BOLTS, SCREWS: <br />A) NAILING SHALL BE AS INDICATED ON PLANS AND COMPLY TO CODES HAVING <br /> JURISDICTION. BOLTS SHALL HAVE STANDARD <br />B) FASTENERS: <br />1) ALL CONNECTORS NOTED TO BE SIMPSON OR EQUIVALENT. <br />2) USE FULL NAILING/BOLTING @ ALL CONNECTIONS U.N.O. <br />3) ALL NAILS TO BE COMMON U.N.O. <br />4) ALL BOLTS TO BE MIN ASTM-A307 <br />5) BOLT HOLES: MAX 1/16 IN. LARGER THAN BOLT DIA. <br />6) ALL BOLTS ON WOOD TO USE M.I. WASHER UNDER HEAD & NUT. <br />7) LAG BOLTS: LEAD HOLES FOR SHANK TO BE SAME AS SHANK; THREADED <br /> PORTION TO BE 60-70% OF SHANK DIA. <br />8) PLATES, SILLS AND SLEEPERS: <br />A) ALL FOUNDATION PLATES OR SILLS AND SLEEPERS ON A CONCRETE OR <br /> MASONRY SLAB, WHICH IS IN DIRECT CONTACT WITH EARTH AND SILLS WHICH <br /> REST ON CONCRETE OR MASONRY FOUNDATIONS, SHALL BE TREATED WOOD OR <br /> FOUNDATION REDWOOD, ALL MARKED OR BRANDED BY AN APPROVED AGENCY. <br /> CUT WASHERS UNLESS OTHERWISE NOTED AND UNLESS USED WITH STEEL <br /> PLATES OR ANGLES. HOLES FOR BOLTS SHALL NOT BE MORE THAN 1/16" <br /> LARGER THAN BOLT DIAMETER. LAG SCREWS SHALL BE TURNED, NOT DRIVEN, <br /> INTO PRE-DRILLED HOLES 2/3 OF THE SHANK DIAMETER. <br />CARPENTRY: (CONTINUED) <br />15. FLOOR JOISTS: <br />A) (BEARING) EXCEPT WHERE JOISTS ARE SUPPORTED ON A 1-INCH BY 4-INCH RIBBON <br /> STRIP AND MAILED TO THE ADJOINING STUD, THE ENDS OF EACH JOIST SHALL HAVE <br /> NOT LESS THAN 1-1/2 INCHES OF BEARING ON WOOD OR METAL, NOR LESS THAN 3 <br /> INCHES OF MASONRY. <br />B) (BLOCKING) JOISTS SHALL BE SUPPORTED LATERALLY AT THE ENDS AND AT EACH <br /> SUPPORT BY SOLID BLOCKING EXCEPT WHERE THE ENDS OF JOISTS ARE MAILED TO A <br /> HEADER, BANK OR RIM JOIST OR TO AN ADJOINING OR BY THEIR APPROVED MEANS. <br /> SOLID BLOCKING SHALL NOT BE LESS THAN 2 INCHES IN THICKNESS AND THE FULL <br /> DEPTH OF JOIST. <br />C) (NOTCHES AND HOLES) NOTCHES ON THE ENDS OF JOISTS SHALL NOT EXCEED <br /> ONE-FOURTH THE JOIST DEPTH. HOLES BORED IN JOISTS SHALL NOT BE WITHIN 2 <br /> INCHES OF THE TOP OR BOTTOM OF THE JOIST AND THE DIAMETER OF ANY SUCH <br /> HOLE SHALL NOT EXCEED ONE-THIRD THE DEPTH OF THE JOIST. NOTCHES IN THE TOP <br /> OR BOTTOM OF JOISTS SHALL NOT EXCEED ONE-SIXTH THE DEPTH AND SHALL NOT BE <br /> LOCATED IN THE MIDDLE THIRD OF THE SPAN. <br />D) (LAPS) JOISTS FRAMING FROM OPPOSITE SIDES OF A BEAM, GIRDER OR PARTITION <br /> SHALL BE LAPPED AT LEAST 4 INCHES OR THE OPPOSING JOISTS SHALL BE TIED <br /> TOGETHER IN AN APPROVED MANNER. <br />E) (FRAMING ANCHORS) JOISTS FRAMING INTO THE SIDE OF A WOOD GIRDER SHALL BE <br /> SUPPORTED BY FRAMING ANCHORS OR ON LEDGER STRIPS NOT LESS THAN 2 INCHES <br /> BY 2 INCHES. <br />F) (FRAMING AROUND OPENINGS) TRIMMER AND HEADER JOISTS WHEN FRAMED AROUND <br /> OPENINGS SHALL BE DOUBLED, OR OF LUMBER OF EQUIVALENT CROSS SECTION, WHEN <br /> THE SPAN OF THE HEADER EXCEEDS 4 FEET. THE ENDS OF HEADER JOISTS MORE THAN <br /> 5 FEET LONG SHALL BE SUPPORTED BY FRAMING ANCHORS OR JOIST HANGERS UNLESS <br /> BEARING ON A BEAM, PARTITION OR WALL. TAIL JOISTS OVER 12 FEET LONG SHALL BE <br /> SUPPORTED AT HEADER BY FRAMING ANCHORS OR ON LEDGER STRIPS NOT LESS THAN <br /> 2 INCHES BY 2 INCHES. <br />G) (SUPPORTING BEARING PARTITIONS) BEARING PARTITIONS PERPENDICULAR TO JOISTS <br /> SHALL NOT BE OFFSET FROM SUPPORTING GIRDERS, WALLS OR PARTITIONS MORE <br /> THAN THE JOIST DEPTH. JOISTS UNDER AND PARALLEL TO BEARING PARTITIONS SHALL <br /> BE DOUBLED. <br />4.CLOTHES DRYER MOISTURE EXHAUST DUCT SHALL BE 4 INCHES IN DIAMETER AND <br /> LENGTH IS LIMITED TO 14 FEET WITH TWO ELBOWS FROM THE CLOTHES DRYER TO <br /> POINT OF TERMINATION. DUCT LENGTH SHALL BE REDUCED BY 2 FEET FOR EVERY <br /> ELBOW IN EXCESS OF TWO. <br />5.THE DWELLING SHALL HAVE WATER CLOSETS (TOILETS), WHICH USE NO MORE THAN <br /> 1.6 GALLONS PER FLUSH. (P.C. 402.3) <br />6.WHERE NM CABLE (ROMEX) IS RUN ACROSS THE TOP OF CEILING JOISTS AND/OR <br /> WHERE THE ATTIC IS NOT ACCESSIBLE BY PERMANENT STAIRS OR LADDERS, <br /> PROTECTION WITHIN 6 FEET OF THE NEAREST EDGE OF THE SCUTTLE HOLE OR <br /> ATTIC ENTRANCE SHALL BE PROVIDED. (E.C. 336-6(D), 333-12) <br />16. ROOF AND CEILING FRAMING: <br />A) (FRAMING) RAFTER SHALL BE FRAMED DIRECTLY OPPOSITE EACH OTHER AT THE RIDGE. <br /> THERE SHALL BE A RIDGE BOARD AT LEAST 2-INCHE NOMINAL THICKNESS AT ALL RIDGES <br /> AND NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER. AT ALL VALLEYS AND HIPS <br /> THERE SHALL BE A SINGLE VALLEY OR HOP RAFTER NOT LESS THAN 2 INCHES NOMINAL <br /> THICKNESS AND NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER. <br />B) (RAFTER TIES) RAFTERS SHALL BE NAILED TO ADJACENT CEILING JOISTS TO FORM A <br /> CONTINUOUS TIE BETWEEN EXTERIOR WALLS WHEN SUCH JOISTS ARE PARALLEL TO THE <br /> RAFTERS. WHERE NOT PARALLEL, RAFTERS SHALL BE TIED TO 1-INCH THICK BY 4-INCH <br /> (NOMINAL) MINIMUM SIZED CROSS TIES. RAFTER TIES SHALL BE SPACED NOT MORE <br /> THAN 4 FEET ON CENTER. <br />C) (PURLING) PURLING TO SUPPORT ROOF LOADS MAY BE INSTALLED TO REDUCE THE SPAN <br /> OF RAFTERS WITHIN ALLOWABLE LIMITS AND SHALL BE SUPPORTED BY STRUTS TO <br /> BEARING WALLS. THE MAXIMUM SPAN OF 2-INCH BY4-INCH PURLING SHALL BE 4 FEET. <br /> THE MAXIMUM SPAN OF THE 2-INCH BY 6-INCH PURLING SHALL BE 5 FEET BUT IN NO <br /> CASE SHALL THE PURLING BE SMALLER THAN THE SUPPORTED RAFTER. STRUTS SHALL BE <br /> NOT SMALLER THAN 2-INCH BY 4 INCH MEMBERS. THE EMBRACED LENGTH OF STRUTS <br /> SHALL NOT EXCEED 8 FEET AND THE MINIMUM SLOPE OF THE STRUTS SHALL BE NOT <br /> LESS THAN 45" FROM THE HORIZONTAL. <br />7.ALL ANCHOR BOLTS, DOWELS AND OTHER INSERTS SHALL BE PLACED BEFORE POURING <br />CONCRETE. <br />8.REINFORCING STEEL: ASTM 4615, GRAD 40, LAP BARS 40 DIAMETERS AT CORNERS AND <br />SPLICES. <br />9.COVER FOR REINFORCING BARS: 3" WHERE DEPOSITED AGAINST EARTH, 2" WHERE <br />EXPOSED TO EARTH AND PLACED IN FORMS. <br /> 10.CURING, SURFACES KEPT CONTINUOUSLY WET NOT LESS THAN 7 DAYS <br /> AFTER POURING. <br /> MECHANICAL/PLUMBING/ELECTRICAL CODE REQUIREMENTS <br />1.THE FOLLOWING ARE REQUIRED FOR THE FORCED AIR FURNACE IN A COMPARTMENT: <br />a. COMPARTMENT DIMENSIONS SHALL HAVE 3" MINIMUM CLEARANCE ON SIDES, BACK, <br /> AND TOP, AND 6" MINIMUM CLEARANCE ALONG THE COMBUSTION CHAMBER <br /> OPENING SIDE OF THE FURNACE. THE MINIMUM WIDTH PERMITTED IS 12" GREATER <br /> THAN THE EQUIPMENT. (M.C. 9041 & 904.7) <br />b. AREA OF COMBUSTION AIR OPENINGS OF 1 SQ. INCH PER 1,000 BTU (100 SQ. INCH <br /> MINIMUM) IS REQUIRED INTO THE COMPARTMENT. HALF OF AREA WITHIN 12 INCHES <br /> OF CEILING AND HALF WITHIN 12 INCHES OF FLOOR.(M.C. 701, 702, 707, & T 7-1) <br />c. COMBUSTI8ON AIR FROM THE ATTIC THROUGH 26 GAUGE GALVANIZED STEEL SLEEVE <br /> EXTENDING 6 INCHES MINIMUM ABOVE CEILING JOISTS WITHOUT A SCREEN AT THE <br /> TOP (ATTIC TO HAVE ADEQUATE OPENINGS). (M.C. 703.1.2.3) <br />d. COMBUSTION AIR FROM OUTSIDE TO COMPARTMENT WITH A ¼" SCREEN AT OUTSIDE <br /> OPENING. (M.C. 702.3) <br />e. SEPARATE DUCTS FOR UPPER AND LOWER COMBUSTION AIR SUPPLY OPENINGS. <br /> (M.C. 704.1.6) <br />9. COLUMNS AND POSTS: <br />A) ALL WOOD COLUMNS AND POSTS SHALL BE FRAMED TO TRUE END BEARINGS. <br /> SUPPORTS SHALL BE DESIGNED TO HOLD THE COLUMN OR POST SECURELY IN <br /> POSITION AND TO PROTECT ITS BASE FROM DETERIORATION. IN AREAS EXPOSED <br /> TO WATER SPLASH AND IN EXTERIOR LOCATIONS, WOOD COLUMNS AND POSTS <br /> SHALL BE SUPPORTED BY PIERS PROJECTING AT LEAST 2 INCHES ABOVE THE <br /> FINISHED FLOOR AND SHALL BEAR ON A METAL BASE PLATE OR A FOUNDATION <br /> PLATE OR SILL. POSTS OR COLUMNS OF TREATED WOOD OR OF FOUNDATION <br /> GRADE REDWOOD OR CEDAR MAYBE PLACED DIRECTLY ON CONCRETE, SOLID <br /> MASONRY OR GROUTED MASONRY. <br />10. WOOD AND EARTH SEPARATION: <br />A) NO UNTREATED WOOD EXCEPT FOUNDATION REDWOOD SHALL BE NEARER THAN 6 <br /> INCHES TO ANY EARTH UNLESS SEPARATED BY CONCRETE AT LEAST 3 INCHES IN <br /> THICKNESS WITH AN IMPERVIOUS MEMBRANE INSTALLED BETWEEN THE EARTH AND <br /> CONCRETE. <br />11. ROOF SHEATHING: <br />A) 1X4 OR 1X6 SPACED; WITH 1X6 SHIP LAP STARTER BOARD AT ALL EXPOSED <br /> RAVES (RE SAWN FACE DOWN); SHALL BE STANDARD, 3 COMMON, NO. 2 OR <br /> CONSTRUCTION GRADES AND SHALL BE SPACED NO MORE THAN 6" CLEAR. <br />D) (BLOCKING) RAFTERS MORE THAN 8 INCHES IN DEPTH SHALL BE SUPPORTED LATERALLY <br /> AT THE ENDS AND AT EACH SUPPORT BY SOLID BLOCKING NOT LESS THAN 2 INCHES IN <br /> THICKNESS AND THE FULL DEPTH OF THE RAFTER UNLESS MAILED TO A HEADER; BAND <br /> OR RIM JOIST OR TO AN ADJOINING STUD. <br />17. WALL FRAMING: <br />A) (SIZE) STUDS IN EXTERIOR WALLS AND INTERIOR BEARING WALLS OF BUILDINGS NOT <br /> MORE THAN TWO STORIES IN HEIGHT SHALL BE NOT LESS THAN 2 INCHES BY 4 INCHES <br /> IN SIZE. FOR THREE-STORY BUILDINGS SUCH STUDS SHALL BE NOT LESS THAN 3 <br /> INCHES BY 4 INCHES OR 2 INCHES BY 6 INCHES TO THE BOTTOM OF THE SECOND <br /> FLOOR JOISTS, AND 2 INCHES BY 4 INCHES FOR THE TWO UPPER STORIES. INTERIOR <br /> NONBEARING PARTITIONS MAY BE FRAMED WITH 2-INCH BY 4 INCH STUDS. <br />B) (HEIGHT) UNLESS, SUPPORTED LATERALLY BY ADEQUATE FRAMING, THE MAXIMUM <br /> ALLOWABLE HEIGHT FOR STUDS SHALL BE 14 FEET FOR 2-INCH BY 4-INCH STUDS; AND <br /> 20 FEET FOR 2-INCH BY 6 INCH. <br />C) (SPACING) STUDS SUPPORTING FLOORS AND CEILINGS OR RAFTERS SHALL BE SPACED <br /> NOT MORE THAN 16 INCHES. <br />D) (CRIPPLE WALLS) CRIPPLE WALLS SHALL BE FRAMED OF STUDS NOT LESS IN SIZE THAN <br /> THE STUDDING ABOVE WITH A MINIMUM LENGTH OF 24 INCHES, OR SHALL BE FRAMED <br /> OF SOLID BLOCKING. WHEN EXCEEDING 4 FEET IN HEIGHT, SUCH WALLS SHALL BE <br /> FRAMED OF STUDS HAVING THE SIZE REQUIRED FOR AN ADDITIONAL STORY. <br />E) (HEADERS) HEADERS FOR ALL OPENINGS 4 FEET WIDE OR LESS IN BEARING WALLS SHALL <br /> BE PROVIDED WITH HEADERS CONSISTING OF EITHER TWO PIECES OF2-INCH FRAMING <br /> LUMBER PLACED ON EDGE AND SECURELY FASTENED TOGETHER OR 4-INCH LUMBER OF <br /> EQUIVALENT CROSS SECTION. ALL OPENINGS MORE THAN 4 FEET WIDE SHALL BE <br /> PROVIDED WITH HEADERS OR LINTELS. SUCH HEADERS OR LINTELS SHALL HAVE NOT <br /> LESS THAN 2-INCH SOLID BEARING AT EACH END TO THE FLOOR OR BOTTOM PLATE, <br /> UNLESS OTHER APPROVED FRAMING METHODS OR JOINT DEVICES ARE USED. <br /> SEE PLAN FOR SIZE. <br />F) (PIPES IN WALLS) STUD PARTITIONS CONTAINING PLUMBING, HEATING, OR OTHER PIPES <br /> SHALL BE SO FRAMED AND THE JOISTS UNDERNEATH SO SPACED AS TO GIVE PROPER <br /> CLEARANCE FOR THE PIPING, WHERE A PARTITION CONTAINING SUCH PIPING RUNS <br /> PARALLEL TO THE FLOOR JOISTS, THE JOISTS UNDERNEATH SUCH PARTITIONS SHALL BE <br /> DOUBLED AND SPACED TO PERMIT THE PASSAGE OF SUCH PIPES AND SHALL BE <br /> BRIDGED, WHERE PLUMBING, HEATING OR OTHER PIPES ARE PLACED IN OR PARTLY IN <br /> A PARTITION, NECESSITATING THE CUTTING OF THE HOLES OR PLATES.A METAL TIE NOT <br /> LESS THAN 1/8 INCH THICK AND 1-1/2 INCHES WIDE SHALL BE FASTENED TO THE PLATE <br /> ACROSS AND TO EACH SIDE OF THE OPENING WITH NOT LESS THAN FOUR 160 NAILS. <br />FINISHES: <br />A. EXTERIOR PLASTER: <br /> 1) PLASTER: EXTERIOR PLASTER SHALL BE PORTLAND CEMENT PLASTER WITH FINISH AS <br /> INDICATED ON EXTERIOR ELEVATIONS. <br /> 2)BASE COATS:THE MIX SHALL CONSIST OF ONE PART PORTLAND CEMENT TO NOT MORE <br /> THAN 3-1/2 PARTS SAND FOR FIRST SCRATCH COAT AND NOT MORE THAN 4 PARTS <br /> SAND FOR THE TEXTURED BROWN COAT. ALL MEASURED BY VOLUME TO WHICH MAY BE <br /> ADDED NOT MORE THAN 10% OF HYDRATED LIME, MIXED WITH WATER IN A BATCH <br /> MIXER TO THE PROPER CONSISTENCY. <br /> 3)PLASTER THICKNESS: <br /> STEP 1 - SCRATCH COAT - 1/4" THICK <br /> STEP 2 - TEXTURED BROWN COAT - 3/8" THICK <br /> STEP 3 - SMOOTH FINISH COAT -1/4" THICK ON 34# METAL LATH AND 15# PELT. <br /> TEXTURED BROWN COAT IS TO HAVE AN UNEVEN BUT SMOOTH FINISH WITH <br /> NO TROWEL MARKS TO BE VISIBLE. PROVIDE SAMPLE TO BE APPROVED <br /> BEFORE PROCEEDING. SMOOTH FINISH COAT TO BE PAINTED USING 20-30 <br /> SILICA SAND FOR SMOOTH HAND APPLIED LOOK. PROVIDE SAMPLE 10' X 10' <br /> AREA TO BE APPROVED. <br /> 4)ALL EXTERIOR PLASTER SHALL CONFORM TO CHAPTER 47, U.B.C. <br /> B. INTERIOR PLASTER: <br /> 1) GYPSUM PLASTER - 3/8" GYPSUM LATH WITH ½" TWO COAT PLASTER OVER THE <br /> CORNER BEADS, CASING BEADS AND REINFORCEMENT AT OPENINGS. <br /> C. GYPSUM WALLBOARD: <br /> 1) ASTM C36 5/8" THICK, WITH TAPERED EDGES, REGULAR AND TYPE X AT 1 HOUR <br /> RATED WALLS. (U.N.O.) <br /> D. PAINTING: <br /> 1) GENERAL - APPLY 1 COAT PRIMER, 2 COAT PAINT, TYPICAL UNLESS NOTED <br /> OTHERWISE. <br /> 2)PAINT SHALL BE SHERWIN-WILLIAMS, W.P. FULLER, DUNN EDWARDS OR SINCLAIR. <br />G) (BRIDGING) ALL STUD PARTITIONS OR WALLS WITH STUDS HAVING A HEIGHT TO LEAST THICKNESS <br /> RATIO EXCEEDING 50 SHALL HAVE BRIDGING NOT LESS THAN 2 INCHES IN THICKNESS AND OF THE <br /> SAME WIDTH AS THE STUDS FITTED SNUGLY AND NAILED THERE TO PROVIDE ADEQUATE LATERAL <br /> SUPPORT, UNLESS COVERED BY INTERIOR OR EXTERIOR WALL COVERING OR SHEATHING MEETING <br /> THE MINIMUM REQUIREMENT OF THE UNIFORM BUILDING CODE APPLICABLE EDITION. <br />H) (CUTTING AND NOTCHING) IN EXTERIOR WALLS AND BEARING PARTITIONS, ANY WOOD STUD MAY BE <br /> CUT OR NOTCHED TO A DEPTH NOT EXCEEDING 25 PERCENT OF ITS WIDTH, CUTTING OR NOTCHING <br /> OF STUDS TO A DEPTH NOT GREATER THAN 40 PERCENT OF THE WIDTH OF THE STUD IS PERMITTED <br /> IN NONBEARING PARTITION SUPPORTING NO LOADS OTHER THAN THE WEIGHT OF THE PARTITION. <br />I) (BORED HOLES) A HOLE NOT GREATER IN DIAMETER THAN 40 PERCENT OF THE STUD MAY BE BORED <br /> IN ANY WOOD STUD. BORED HOLES NOT GREATER THAN 60 PERCENT OF THE WIDTH OF THE STUD <br /> ARE PERMITTED IN NONBEARING PARTITION OR IN ANY WALL WHERE EACH BORED STUD IS DOUBLED <br /> PROVIDED NOT MORE THAN TWO SUCH SUCCESSIVE DOUBLED STUDS ARE SO BORED. IN NO CASE <br /> SHALL THE EDGE OF THE BORED HOLE BE NEARER THAN 5/8 INCH TO THE EDGE OF THE STUD. <br /> BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF THE STUD AS A CUT OR NOTCH <br />J) ROUGH WINDOW SILLS OVER 8 FEET IN LENGTH SHALL BE DOUBLED. <br />K) BLOCKING TO BE PROVIDED AT ALL HANDRAILS. <br />ENERGY: <br />A.BUILDING ENVELOPE: <br /> 1) DOORS AND WINDOWS BETWEEN CONDITIONED AND UNCONDITIONED SPACE MUST BE <br /> FULLY WEATHER-STRIPPED. <br /> 2)THE FOLLOWING OPENINGS IN THE BUILDING ENVELOPE SHALL BE CAULKED OR SEALED: <br /> A) EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES. <br /> B) BETWEEN EXTERIOR WALL SOLE PLATES AND FLOORS AND BETWEEN EXTERIOR WALL <br /> PANELS. <br /> C) PENETRATIONS IN WALLS, CEILINGS, AND FLOORS FOR PLUMBING AND ELECTRICAL <br /> DISTRIBUTION SYSTEMS. <br /> D) OPENINGS IN ATTIC FLOORS. <br /> E) ALL OTHER OPENINGS IN THE BUILDING ENVELOPE. <br /> 3) MANUFACTURED DOORS AND WINDOWS MUST BE LABELED AND CERTIFIED PER ANSI, <br /> AAMA, NWMA, FHDA, OR ASTM STANDARDS. <br /> 4) EXHAUST FANS SHALL BACK DRAFT OR AUTOMATIC DAMPERS. <br />2.THE FOLLOWING ARE REQUIRED FOR FURNACE OR COMFORT COOLING EQUIPMENT IN <br /> AN ATTIC: <br />a. SCUTTLE 22"X30" OR THE SIZE OF THE LARGEST PIECE OF EQUIPMENT AND <br /> LOCATED NOT OVER 20 FEET FROM EQUIPMENT IS REQUIRED. (M.C. 908) <br />b. 24 INCHES WIDE UNOBSTRUCTED PASSAGEWAY OF SOLID CONTINUOUS FLOORING <br /> FROM SCUTTLE TO EQUIPMENT AND ITS CONTROLS. (M.C. 908) <br />c. UNOBSTRUCTED WORKSPACE OF 30" MIN. DEPTH IN FRONT OF EQUIPMENT. <br /> (M.C.908) <br />d. LIGHT OVER EQUIPMENT WITH A SWITCH AT THE SCUTTLE. (M.C. 908) <br />e. VENT THROUGH THE ROOF A MIN OF 5 FEET ABOVE THE HIGHEST VENT COLLAR, <br /> WHICH IT SERVES. (M.C. 806.2) <br />f. FURNACE INSTALLATION SHALL MEET ALL LISTED CLEARANCE. (M.C. 304) <br />3. CLOTHES DRYER MOISTURE EXHAUST DUCT SHALL TERMINATE ON THE OUTSIDE OF <br /> THE BUILDING AND SHALL BE EQUIPPED WITH A BACK-DRAFT DAMPER (NOT IN <br /> CRAWL SPACES OR IN ATTIC AREAS). (M.C. 504.3) <br />B) PLYWOOD SHEATHING IS TO BE CONTINUOUS OVER TWO OR MORE SPANS <br /> AND IS TO BE MINIMUM 1/2" THICK AND HAVE PANEL IDENTIFICATION <br /> INDEX AS REQUIRED FOR RAFTER SPACING (SEE PLANS); ALL SHALL BE <br /> STRUCTURAL AND II, STANDARD SHEATHING, AND C-D GRADES ONLY. <br />12. FLOOR SHEATHING: <br />A) PLYWOOD COMBINATION SUB-FLOOR UNDER-LAYMENT SHEATHING <br /> CONTINUOUS OVER TWO OR MORE SPANS SHALL BE MINIMUM 5/8" THICK <br /> TONGUE-AND GROOVE AND SPACING (SEE PLANS) AND SHALL BE <br /> UNDER-LAYMENT GRADE, C-C (PLUGGED) AND ALL GRADES OF SANDED <br /> EXTERIOR TYPE PLYWOOD IN GROUP SPECIES OF 1, 2, OR 3, WHERE FLOOR <br /> JOISTS SPACING IS 48"O/C USE 1-1/8" THICK TONGUE-AND-GROOVE <br /> 2-4-1 (EXTERIOR GLUE) PLYWOOD IN GROUP SPECIES OF 1, 2, OR 3. <br />13. FRAMING PRACTICES: <br />A) WORKMANSHIP: <br />1) ALL MEMBERS SHALL BE FRAMED, ANCHORED, TIED, AND BRACED SO AS TO <br /> DEVELOP THE STRENGTH AND RIGIDITY NECESSARY FOR THE PURPOSES FOR <br /> WHICH THEY ARE USED. <br />B) BEAMS AND GIRDERS: <br />1) THE ENDS OF BEAMS OR GIRDERS SUPPORTED ON MASONRY OR CONCRETE <br /> SHALL HAVE NOT LESS THAN 4 INCHES OF BEARING. <br />HEATING: <br />1. HEATING AND VENTILATING: <br /> A) MATERIALS: <br /> 1) PROVIDE 48 SQ. IN. DUCT THROUGH ROOF OR WALL TO OUTSIDE AIR FOR VENT OVER KITCHEN <br /> RANGE. <br /> 2) ALL BATHROOM AND LAUNDRIES WITHOUT WINDOWS SHALL BE PROVIDED WITH AN CAPABLE OF <br /> FIVE AIR CHANGES EVERY HOUR. <br /> 3) FORCED-AIR FURNACES SHALL BE PROVIDED WITH HIGH AND LOW COMBUSTION AIR FROM <br /> OUTSIDE AIR WHEN LOCATED IN COMPARTMENT WITHIN THE DWELLING UNIT. <br /> 4) DELETED. <br /> 5) FORCED-AIR FURNACES SHALL HAVE SUMMER SWITCH WITH 30% FRESH <br /> OUTSIDE AI INTAKE. <br /> 5)MASONRY AND FACTORY-BUILT FIREPLACES SHALL HAVE THE FOLLOWING: <br /> A)TIGHT FITTING CLOSEABLE METAL OR GLASS DOORS COVERING THE ENTIRE <br /> OPENING OF THE FIREBOX. <br /> B)A COMBUSTION AIR INTAKE TO DRAW AIR FROM OUTSIDE THE BUILDING <br /> DIRECTLY INTO FIREBOX, WHICH IS AT LEAST SIX SQUARE INCHES IN AREA <br /> AND IS EQUIPPED WITH A READILY ACCESSIBLE, OPEN ABLE, AND TIGHT <br /> FITTING DAMPER. APPLIES TO EXTERIOR WALLS ONLY. <br />MASONRY: <br />1.CONCRETE MASONRY LIMITS: UNLESS OTHER WISE NOTED ON THE ARCHITECTURAL OR <br />STRUCTURAL DRAWINGS, CONCRETE MASONRY SHALL BE C 90 "FOLLOW CONCRETE MASONRY <br />UNITS". LATEST REVISION. <br />2.MINIMUM COMPRESSIVE STRENGTH 2000 PSI AT 28 DAYS. COLOR TO BE AS NOTED ON THE <br />ARCHITECTURAL DRAWINGS AND APPROVED BY THE ARCHITECT AND OWNER FROM SAMPLES <br />SUBMITTED BY CONTRACTOR PRIOR TO INSTALLATION. <br />3.PORTLAND CEMENT: LOW ALKALI AND CONFORMING TO ASTM C 15, TYPE II. <br />4.MOTOR SAND: ASTM C 144, NOT LESS THAN 4% PASSING NO. 100 SIEVE, UNIFORMLY <br />GRADED. <br />5.GROUT SAND: ASTM C 404, NATURAL, SIZE NO 1. <br />6.PEA GRAVEL: ASTM C 404, GRAVEL, EXCEPT MAXIMUM 5% PASSING. <br />2) ALL BEAM OR GIRDERS SUPPORTED ON WOOD SHALL HAVE FULL BEARING <br /> AND BEARING SHALL BE COMPRISED OF ONE (1) SOLID SUPPORT OR A <br /> BUILT-UP SUPPORT CONSTRUCTED IN AN APPROVED MANNER UNLESS <br /> OTHERWISE SPECIFIED ON PLANS. <br />14. BALLOON FRAME TABLE: <br />A) (1) 2 X 4 AT 16" O/C 14'-0" MAX. LATERALLY UNSUPPORTED HEIGHT <br />B) (2) 2 X 4 AT 16" O/C 16'-0 MAX. LATERALLY UNSUPPORTED HEIGHT <br />C) (3) 2 X 4 AT 16" O/C 18'-0 MAX LATERALLY UNSUPPORTED HEIGHT <br />D) (4) 2 X 4 AT 16" O/C 20'-0 MAX LATERALLY UNSUPPORTED HEIGHT <br />E) (1) 2 X 6 AT 16" O/C 20'-0 MAX LATERALLY UNSUPPORTED HEIGHT <br />* W.C.D.F. NO. 2 OR BETTER AND NAIL WITH 16D AT 24" O/C <br /> C) TIGHT FITTING FLUE DAMPER WITH A READILY ACCESSIBLE CONTROL. <br /> D) CONTINUOUS BURNING PILOT IS PROHIBITED. <br />6) CONTRACTOR SHALL POST INSULATION COMPLIANCE CARD IN A <br /> CONSPICUOUS LOCATION ON THE JOB SITE. <br />This drawings,specifications and ideas, <br />with these drawings shall constitute evidence <br />Disclaimer <br />GENERAL <br />NOTES <br />SHEET TITLE <br />REVISIONS <br />designs thereby are and shall remain the <br />property of F. Solis (Draftsman) and no part <br />thereof shall be copied disclosed to <br />others or used in connection with any <br />work or project for which there have been <br />prepared and developed,without the <br />the written consent of F. Solis, visual contact <br />of acceptance of these restrictions. <br />Sheet <br />A2 <br />AD <br />U <br />11 <br />2 <br />3 <br /> <br />M <br />A <br />G <br />N <br />O <br />L <br />I <br />A <br /> <br />A <br />V <br />E <br /> <br />U <br />N <br />I <br />T <br /> <br /># <br />2 <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />, <br /> <br />C <br />A <br /> <br />, <br />9 <br />2 <br />7 <br />0 <br />7 <br />1 PLAN CHECK 10.08.24 <br />2 PLAN CHECK 11.18.24 <br />DR <br />A <br />W <br />I <br />N <br />G <br />S <br /> <br />P <br />R <br />E <br />P <br />A <br />R <br />E <br />D <br /> <br />B <br />Y <br />: <br />FR <br />A <br />N <br />K <br /> <br />S <br />O <br />L <br />I <br />S <br />58 <br />6 <br />8 <br /> <br />A <br />G <br />R <br />A <br /> <br />S <br />T <br />BE <br />L <br />L <br /> <br />G <br />A <br />R <br />D <br />E <br />N <br />S <br />, <br /> <br />C <br />A <br /> <br />9 <br />0 <br />2 <br />0 <br />1 <br />1123 S Magnolia Ave <br />Unit# 22/19/2025