Laserfiche WebLink
<br /> <br />DESIGN REPORT <br /> <br />Date: 12/1/2023 <br />REV: A <br />page 32 of 160 <br />JOB# 186565 <br /> <br /> <br /> <br /> <br /> <br /> <br /> LAYOUT: <br /> ------- <br /> Bay Design ---Lap(ft)-- No. Unit Total <br /> Id Part Length Left Right Strap Weight Weight <br /> ---- -------- ------ ----- ----- ----- ------ ------ <br /> LExt 8X35Z14 0.33 0 1.3 5.1 <br /> 1 8X35Z14 24.67 3.15 0 105.4 421.6 <br /> 2 8X35Z14 24.33 3.15 0 104.1 416.6 <br /> RExt 8X35Z14 0.67 0 2.5 10.1 <br /> ------ ------ <br /> Total(lb)= 213.3 853.4 <br /> <br /> <br /> <br /> <br /> LOAD COMBINATIONS: <br /> ------------------ <br /> 3 - Dead+Collateral+0.75Live+0.45Wind_Pressure1 <br /> <br />================================================================================ <br /> 186565FS Purlin(Surface 3, Id 3) 12/ 1/23 1:53pm <br />================================================================================ <br /> ------------------------------ <br /> ROOF PURLIN <br /> Surface Id = 3 <br /> Purlin Id = 3 <br /> Offset = 11.25 <br /> ------------------------------ <br /> <br /> LAYOUT (Purlin Id= 3): <br /> ----------------------- <br /> Available <br /> Design Reduction <br /> Bay Length ---Lap(ft)-- Load No. Factor ----Max_Load---- <br /> Id Part (ft) Left Right Width Strap Out In Id UC Report <br /> ---- -------- ------ ----- ----- ----- ----- ---- ---- --- ---- ------- <br /> LExt 8X35Z14 0.33 4.96 0 0.00 0.70 3 0.01 Mom,Shr <br /> 1 8X35Z14 24.67 3.15 4.96 0 0.00 0.70 3 0.94 Mom,Shr <br /> 2 8X35Z14 24.33 3.15 4.96 0 0.00 0.70 3 0.95 Mom,Shr <br /> RExt 8X35Z14 0.67 4.96 0 0.00 0.70 3 0.02 Mom,Shr <br /> <br /> LOAD ID 1 - Dead+Collateral+Live: <br /> ----------------------------------- <br /> <br />1202 W Edinger <br />Ave10/3/2024