My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1202 W Edinger Ave - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Edinger Ave
>
1202 W Edinger Ave
>
1202 W Edinger Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2025 11:12:26 PM
Creation date
6/1/2025 11:56:24 AM
Metadata
Fields
Template:
Plan
Permit Number
20180981
40138401
101116627
Full Address
1202 W Edinger Ave
Street Number
1202
Street Direction
W
Street Name
Edinger
Street Suffix
Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Mater Dei High School October 20, 2023 <br />Proposed Dance Studio, Santa Ana, California Project No. 3204.I <br /> <br />3204-I-01R (10/23) 2 <br /> <br />2.0 SCOPE OF WORK <br /> <br />Our scope of work included review of existing information, field investigation, laboratory <br />testing, engineering analyses, and preparation of this report. <br /> <br />Our field exploration consisted of two exploratory borings. The borings were advanced <br />to depths ranging from 20 to 50½ feet below existing site grades. Detailed logs of the <br />borings and a summary of the equipment used are presented in Appendix A. The <br />locations of the subsurface explorations are shown on the Site Plan, Figure 3. <br /> <br />Laboratory soil tests were performed on selected representative samples as an aid in soil <br />classification and to evaluate the engineering properties of the soils. The geotechnical <br />laboratory testing program used for this investigation included evaluations of in-place <br />moisture content and dry density, Atterberg Limits, direct shear, consolidation, maximum <br />density, expansion potential, and corrosivity. Laboratory testing procedures and results <br />are summarized in Appendix B. <br /> <br />Soil corrosivity testing was performed by Project X Corrosion under subcontract to GPI. <br />Their test results are presented in Appendix B. <br /> <br />Engineering evaluations were performed to provide earthwork criteria, foundation and <br />slab design parameters and assessments of seismic hazards. The results of our <br />evaluations are presented in the remainder of the report. <br /> <br /> <br /> <br />1202 W Edinger <br />Ave10/3/2024
The URL can be used to link to this page
Your browser does not support the video tag.