Mater Dei High School October 20, 2023 <br />Proposed Dance Studio, Santa Ana, California Project No. 3204.I <br /> <br />3204-I-01R (10/23) 11 <br />• Dowel connections between footings and floor slab. <br /> <br />The static and seismic settlements as provided in this report must be considered by the <br />Project Structural Engineer. We assume that the design of the structures will at a <br />minimum prevent the collapse of the building should the seismic settlements, as <br />estimated in this report, occur during a design earthquake. <br /> <br />The subsurface soils should be prepared in accordance with the recommendations given <br />in this report. <br /> <br />4.4.2 Mat Foundation <br /> <br />The mat pressure near the center of a mat foundation (approximately 2000 sf) supporting <br />the structure is anticipated to range from approximately 100 to 200 psf for the single story <br />building. We estimate the ground surface under the center of a loaded area having the <br />above dimensions and the aforementioned applied pressure will settle approximately ½- <br />inch due to gravity loads. The outside edge of this area under the same loading conditions <br />is expected to settle approximately ¼-inch. The outside corner of this area under the <br />same loading conditions is expected to settle less than ¼-inch. The static settlements <br />assume a uniformly applied pressure and do not include the effects (stiffness) of the mat. <br />The actual settlement of the mat will depend on the stiffness of the mat and its ability to <br />distribute the loads, and should be determined by the Structural Engineer. If the assumed <br />pressures are greater, we should be consulted to determine the effects of these <br />pressures. <br /> <br />Seismic settlement caused by liquefaction should be added to the above settlement <br />values when evaluating the total settlement (static and seismic) of the mat foundation. As <br />previously provided in this report, the potential for total seismic settlement under the mat <br />foundation expected to be on the order of 2 inches. Maximum differential settlements <br />along a 40-foot span are expected to be on the order of 1-inch. <br /> <br />For the structural analysis of the mat foundation, we recommend using an uncorrected <br />modulus of subgrade reaction of 120 pounds per cubic inch (pci) for static conditions. <br />This value is based on a 1-foot square bearing area and compacted silty sands. We <br />recommend this modulus be reduced by 75 percent to a value of 30 pci to account for the <br />size of the mat foundation. In addition, the structural analysis of the mat should consider <br />the seismic settlements discussed above. <br /> <br />The allowable bearing pressure for the mat foundation will be significantly greater than <br />the average bearing pressures required for the mat as discussed above. At localized <br />areas of the mat, such as columns and point of load applications, a static allowable net <br />bearing pressure of 1,500 pounds per square foot may be used. These allowable bearing <br />pressures are for dead-plus-live loads, and may be increased one-third for short-term, <br />transient, wind and seismic loading. <br /> <br />4.4.3 Shallow Foundations <br /> <br />Based on the shear strength and elastic settlement characteristics of the recompacted <br />on-site soils, static allowable net bearing pressures of up to 3,000 pounds per square foot <br />1202 W Edinger <br />Ave10/3/2024