Laserfiche WebLink
tk1sc project number: B2305501.000 <br />drawn by:checked by: <br />drawing no.: <br />ar <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />pl <br />a <br />n <br />n <br />i <br />n <br />g <br />in <br />t <br />e <br />r <br />i <br />o <br />r <br />s <br />tB <br />P <br />/ <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />46 <br />1 <br />1 <br /> <br />T <br />e <br />l <br />l <br />e <br />r <br /> <br />A <br />v <br />e <br />n <br />u <br />e <br />Ne <br />w <br />p <br />o <br />r <br />t <br /> <br />B <br />e <br />a <br />c <br />h <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />6 <br />0 <br />ph <br />: <br /> <br />9 <br />4 <br />9 <br />. <br />6 <br />7 <br />3 <br />. <br />0 <br />3 <br />0 <br />0 <br />consultant <br />agency <br />owner <br />date: <br />drawing title: <br />description:date:Rev: <br />tBP project number : <br />architect <br />THIS DRAWING AND THE DESIGNS, DEPICTIONS, IDEAS AND OTHER INFORMATION <br />CONTAINED HEREIN CONSTITUTE UNPUBLISHED WORK OF tBP/ARCHITECTURE AND <br />SHALL REMAIN THE PROPERTY OF tBP/ARCHITECTURE IN PERPETUITY. NO PART <br />THEREOF SHALL BE REPRODUCED, DISCLOSED, DISTRIBUTED, SOLD, PUBLISHED OR <br />OTHERWISE USED IN ANY WAY WITHOUT THE ADVANCED EXPRESS WRITTEN CONSENT <br />OF tBP/ARCHITECTURE. <br />ph: 714.667.2700 <br />SANTA ANA, CA 92701 <br />20 CIVIC CENTER PLAZA <br />SANTA ANA PLANNING AND BUILDING AGENCY <br /># <br />DA <br />N <br />C <br />E <br /> <br />S <br />T <br />U <br />D <br />I <br />O <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />12 <br />0 <br />2 <br /> <br />W <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />MA <br />T <br />E <br />R <br /> <br />D <br />E <br />I <br /> <br />H <br />I <br />G <br />H <br /> <br />S <br />C <br />H <br />O <br />O <br />L <br />21125.00 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />12 <br />0 <br />2 <br /> <br />W <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />MA <br />T <br />E <br />R <br /> <br />D <br />E <br />I <br /> <br />H <br />I <br />G <br />H <br /> <br />S <br />C <br />H <br />O <br />O <br />L <br />21125.00 <br />09/06/2023 <br />11870 Pierce Street, Suite 160 <br />Riverside, California 92505 <br />951.299.4160 www.tk1sc.com <br />Project Leader - Bill Voller <br />tk1sc Job #: B2305501.000 <br />Electrical Lead - Marie Rothenberger <br />City Submittal 09/06/23- <br />LIGHTING CONTROL <br />SPECIFICATIONS <br />E3-5 <br />12. <br />a. <br />b. <br />DLCS COMPONENTS SHALL BE BE PROVIDED AS FOLLOWS: <br />g.WHERE INDICATED ON DRAWINGS, PROVIDE DLCS DAYLIGHTING CONTROLS AS FOLLOWS: <br />1)AUTOMATIC SWITCHING DAYLIGHTING CONTROLS SHALL BE PROVIDED TO SWITCH SELECTED FIXTURES AND/OR <br />LAMPS OFF AND ON BASED UPON LIGHTING LEVELS PRESENT IN THE CONTROLLED SPACE. THE DAYLIGHTING <br />CONTROLS SHALL BE CONNECTED TO THE CONTROL UNIT. THE SENSOR SHALL UTILIZE AN INTEGRAL PHOTO <br />DIODE TO MEASURE AMBIENT LIGHT LEVELS. CONTROLS SHALL BE FULLY ADJUSTABLE FROM 1 TO 6,500 <br />FOOTCANDLES AND SHALL BE PROVIDED WITH AN ADJUSTABLE TIME DELAY AND ADJUSTABLE DEAD BAND <br />SETTINGS. <br />2)AUTOMATIC DIMMING DAYLIGHTING CONTROLS SHALL BE PROVIDED TO CONTINUOUSLY DIM SELECTED <br />FIXTURES/LAMPS UP AND DOWN BASED UPON LIGHTING LEVELS PRESENT IN THE CONTROLLED SPACE. THE <br />SENSOR SHALL UTILIZE AN INTERNAL PHOTO DIODE TO MEASURE AMBIENT LIGHT LEVELS. 0-10 VOLT DIMMING <br />CONTROLS SHALL RANGE FROM 0.2 VOLTS TO 10 VOLTS, WITH AMBIENT LIGHTING SET POINTS FROM 1-6,500 <br />FOOTCANDLES. <br />f. <br />e. <br />f. <br />c. <br />b. <br />a. <br />INSTALLATION OF CONTROL UNITS, OCCUPANCY/VACANCY SENSORS AND DAYLIGHTING CONTROLS: <br />AS PART OF THE "RECORD DRAWINGS", INDICATE ON THE REFLECTED CEILING PLAN THE EXACT LOCATION (CEILING <br />TILE OR ACCESS PANEL) OF ANY ABOVE CEILING DEVICE. <br />UPON COMPLETION OF THE INSTALLATION, THE SYSTEM SHALL BE COMPLETELY COMMISSIONED BY THE <br />MANUFACTURER'S FACTORY AUTHORIZED TECHNICIAN WHO WILL VERIFY ALL ADJUSTMENTS AND SENSOR PLACEMENT <br />TO ENSURE A TROUBLE-FREE INSTALLATION. THIS COMMISSIONING EFFORT SHALL BE PERFORMED IN A MANNER THAT <br />MEETS ALL APPLICABLE FEDERAL, STATE, LOCAL ENERGY CODES AND/OR LEED CERTIFICATION PROGRAMS. THE <br />CONTRACTOR SHALL BE RESPONSIBLE FOR FILLING OUT ALL APPLICABLE PAPERWORK AND/OR FORMS. CONTRACTOR <br />TO PROVIDE A COPY OF THE COMPLETED FORMS TO THE ENGINEER OF RECORD PRIOR TO THE PUNCH LIST SITE VISIT <br />FOR REVIEW AND POSSIBLE RECOMMENDATION OF SETTING REVISIONS. <br />PROPER JUDGMENT MUST BE EXERCISED IN EXECUTING THE INSTALLATION SO AS TO ENSURE THE BEST POSSIBLE <br />INSTALLATION IN THE AVAILABLE SPACE AND TO OVERCOME LOCAL DIFFICULTIES DUE TO SPACE LIMITATIONS OR <br />INTERFERENCE OF BUILDING STRUCTURAL COMPONENTS. <br />IT IS THE CONTRACTOR'S RESPONSIBILITY TO ARRANGE A PRE-INSTALLATION MEETING WITH THE MANUFACTURER'S <br />FACTORY AUTHORIZED REPRESENTATIVE, AT THE PROJECT, TO VERIFY PLACEMENT OF SENSORS AND INSTALLATION <br />CRITERIA. <br />ALL SENSORS SHALL BE ADJUSTED PER THE DLCS SOO/ZONE SCHEDULE. WHERE A ROOM TYPE IS NOT INDICATED ON <br />THE DLCS SOO, ADJUST FOR FOR A TIME DELAY OF TWENTY (20) MINUTES. <br />CEILING MOUNTED SENSORS SHOULD BE LOCATED IN THE SPACE TO BE COVERED, A MINIMUM OF 4', PREFERABLY 5', <br />AWAY FROM THE LATCH SIDE OF THE DOOR, 2" TO 3" AWAY FROM THE WALL AND 3' TO 4' FROM AN AIR SUPPLY <br />REGISTER. DO NOT MOUNT SENSORS OVER A DOORWAY OR BEHIND A FULL HEIGHT DOOR. SENSORS SHALL BE AIMED <br />IN THE DIRECTION OF THE SPACE TO BE COVERED. DO NOT AIM SENSORS TOWARD A DOORWAY. THE USE OF <br />FACTORY SUPPLIED INTERNAL MASKING (PIR) SHALL BE PROVIDED/INSTALLED AS REQUIRED TO LIMIT DETECTION TO <br />WITHIN THE CONTROLLED SPACE ONLY. <br />IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO LOCATE AND AIM SENSORS IN THE CORRECT LOCATION <br />REQUIRED FOR COMPLETE AND PROPER VOLUMETRIC COVERAGE PER THE MANUFACTURER'S RECOMMENDATIONS. <br />ROOMS SHALL HAVE NINETY (90) TO ONE HUNDRED (100) PERCENT COVERAGE AND SHALL ACCOMMODATE ALL HABITS <br />OF SINGLE OR MULTIPLE OCCUPANTS AT ANY LOCATION WITHIN THE ROOM. THE LOCATIONS AND QUANTITIES OF <br />SENSORS SHOWN ON THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE ONLY THE ROOMS THAT ARE TO BE <br />PROVIDED WITH SENSORS. THE CONTRACTOR SHALL PROVIDE ADDITIONAL SENSORS AS REQUIRED TO PROPERLY <br />AND COMPLETELY COVER THE RESPECTIVE ROOM. WHERE PIR-ONLY WIRELESS CEILING OR FIXTURE-INTEGRAL <br />OCCUPANCY SENSORS ARE UTILIZED, PROVIDE QUANTITY AS REQUIRED TO MAINTAIN THE SAME COVERAGE AND SAME <br />MOVEMENT DETECTION SENSITIVITY AS PROVIDED BY WIRED DUAL TECHNOLOGY SENSORS. ADDITIONALLY, IT MAY BE <br />NECESSARY FOR THE CONTRACTOR TO MAKE ADJUSTMENTS, CHANGE THE LOCATION OR TYPE OF SENSOR TO OBTAIN <br />PROPER OPERATION IN A SPECIFIC ROOM. THE USE OF FACTORY-SUPPLIED INTERNAL MASKING (PIR) SHALL BE <br />PROVIDED/INSTALLED AS REQUIRED TO LIMIT DETECTION TO WITHIN THE CONTROLLED SPACE ONLY. WHERE MASKING <br />IS NOT AVAILABLE AS A FACTORY-SUPPLIED ITEM, ALTERNATE FACTORY-SUPPLIED MEANS OF COMPLIANCE OR <br />METHODS MAY BE ACCEPTABLE. THE CONTRACTOR SHALL HAVE FINAL RESPONSIBILITY FOR PROPER OPERATION OF <br />THE SYSTEM IN EACH ROOM AND SHOULD THEREFORE MAKE LABOR ALLOWANCES FOR CHANGES AND ADJUSTMENTS. <br />h.PROVIDE CONTROL UNITS AND SYSTEM FUNCTIONALITY AS FOLLOWS: <br />CONTINUOUS DIMMING CONTROLS: SYSTEM-BASED WALL OR CEILING MOUNTED OCCUPANCY SENSORS <br />(CONTINUOUS DIMMED - AUTO ON 50%/MANUAL ON 100%) SHALL BE PROVIDED WITH CONTROL UNITS TO PERFORM <br />THE FIXTURE DIMMING REQUIREMENTS INDICATED BY THE BALLAST AND FIXTURE TYPE. SWITCH LEG INDICATED <br />OUTSIDE THE PARENTHESIS TO BE CONFIGURED AS "AUTO ON 50%/MANUAL ON 100%" FOR CONTINUOUS DIMMED. <br />SWITCH LEGS INSIDE PARENTHESIS INDICATES A MANUAL ACTION REQUIRED TO INCREASE LIGHTING LEVELS <br />ABOVE 50%. CONTROL UNITS WITH INTEGRAL TRANSFORMERS SHALL BE UTILIZED TO PROVIDE POWER TO <br />OCCUPANCY SENSORS AND OTHER CONTROL DEVICES. CONTROL UNITS SHALL BE LOCATED WITHIN JUNCTION <br />BOXES AND NOT EXPOSED IN THE CEILING SPACE. CONTROL UNIT SHALL BE 120/277 VOLT RATED WITH NO <br />MINIMUM LOAD, COMPATIBLE WITH ALL THE SPECIFIED BALLASTS PROVIDED WITH A NEUTRAL CONNECTION (NO <br />LEAKAGE TO GROUND) AND NO LEAKAGE TO LOAD IN THE "OFF" MODE. ADDITIONAL RELAY ZONES MAY BE <br />REQUIRED FOR THE ADDITION OF PRIMARY DAYLIT, SECONDARY DAYLIT, AND PRIMARY SKYLIT UTILIZING THE <br />SAME CONTROL CHANNEL. (I.E. EVEN THOUGH A SINGLE LETTER "a" IS INDICATED AT THE PRIMARY SENSOR), <br />ADDITIONAL RELAYS WOULD BE REQUIRED FOR THE "a+" (PRIMARY SIDELIT DAYLIT ZONE), "a++" (SECONDARY <br />SIDELIT DAYLIT ZONE), AND "a*" (SKYLIT DAYLIT ZONE). WHERE MORE THAN ONE CIRCUIT/THREE SWITCH <br />LEGS/THREE RELAY ZONES ARE REQUIRED, PROVIDE ADDITIONAL FULL FEATURE CONTROL UNITS AS REQUIRED. <br />1) <br />DISTRIBUTED LIGHTING CONTROLS SYSTEM SPECIFICATIONS (OCCUPANCY / VACANCY SENSORS AND DAYLIGHTING CONTROLS): <br />AUTOMATIC DAYLIGHTING CONTROLS SHALL BE CONNECTED TO CONTROL UNITS TO PERFORM THE FIXTURE <br />SWITCHING/DIMMING REQUIREMENTS INDICATED BY THE DRAWINGS - CONNECTIONS DIRECTLY TO A BALLAST ARE <br />NOT ALLOWED. <br />SEE LIGHTING PLAN DRAWINGS FOR DISTRIBUTED LIGHTING CONTROL SYSTEM (DLCS) SPECIFICS, SPACE SPECIFIC <br />CONFIGURATIONS/REQUIREMENTS, AS WELL AS FIXTURE BALLAST/DRIVER CONFIGURATIONS. <br />d.EACH DAYLIGHTING CONTROL SYSTEM/ZONE SHALL BE INSTALLED/ADJUSTED AS FOLLOWS: <br />1)AUTOMATIC SWITCHING/DIMMING CONTROL PLACEMENT: IT IS IMPORTANT TO SELECT A LOCATION IN THE <br />DAYLIGHTING ZONE WHERE THE DAYLIGHT CONTRIBUTION IS REPRESENTATIVE OF THE DAYLIGHTING <br />THROUGHOUT THE ZONE. A GOOD LOCATION IS OFTEN BETWEEN THE WINDOW AND/OR DAYLIGHTING SOURCE <br />AND THE FIRST ROW OF LIGHTING FIXTURES. AVOID INSTALLATIONS WITHIN 6'-0" OF A WINDOW, MORE THAN 15'-0" <br />FROM A WINDOW, AND LESS THAN 4'-0" TO A LIGHTING FIXTURE WITH INDIRECT DISTRIBUTION. <br />2)AUTOMATIC STEP-DIMMED/CONTINUOUS DIMMING CONTROLS SHALL NOT BE OPERATIONAL UNTIL THE LAMPS <br />HAVE HAD AN OPPORTUNITY TO "BURN IN" - TYPICALLY A MINIMUM OF 10 HOURS - OR GREATER AS <br />RECOMMENDED BY THE RESPECTIVE LAMP AND BALLAST MANUFACTURERS. <br />3)AUTOMATIC SWITCHING/STEP-DIMMED CONTROL SETTINGS: <br />4)AUTOMATIC CONTINUOUS DIMMING CONTROL SETTINGS SHALL BE SET USING AN ILLUMINANCE METER, AT A <br />LOCATION FURTHEST FROM THE DAYLIGHT SOURCE, AS FOLLOWS: <br />-NIGHT CONDITIONS/SETTING: SET AND ADJUST THE ILLUMINANCE LEVELS TO BE PER THE "TARGET <br />ILLUMINATION" SYMBOL VALUE - SEE DLCS SOO/ZONE SCHEDULE. THE VALUE MUST BE AT OR BELOW THE <br />"TARGET ILLUMINATION" SYMBOL VALUE. <br />-DAY CONDITIONS/SETTING: WITH WINDOW COVERINGS IN THE "OPEN" POSITION AND THE DAYLIGHT <br />CONTRIBUTION (LIGHTS OFF) AT A MAXIMUM OF 75% OF THE "TARGET ILLUMINATION" SYMBOL VALUE, SET AND <br />ADJUST THE COMBINED ARTIFICIAL ILLUMINATION AND DAYLIGHTING ILLUMINATION TO MEET THE SYMBOL <br />VALUE AT THE SAME LOCATION/POSITION OF THE NIGHT SETTINGS. <br />CONTRACTOR SHALL INCLUDE ALL COST IN THE BASE BID AND PROVIDE THE FOLLOWING WORK FOR EVERY CONTROL <br />ZONE: <br />INITIAL SETTINGS AS INDICATED ON SOO/ZONE SCHEDULE. <br />COMMISSIONING OF EACH LIGHTING CONTROL DEVICE/ZONE PER NOTES BELOW. <br />A FOLLOW UP SETTING(S) ADJUSTMENT, AS DICTATED BY THE ELECTRICAL ENGINEER, BASED UPON A REVIEW OF <br />THE RESULTS OF THE CONTRACTOR'S COMMISSIONING EFFORT AND FINAL PUNCH LIST. <br />REGARDLESS OF THE LESSER REQUIREMENTS OF ANY AHJ COMMISSIONING FORMS, THE FOLLOWING MINIMUM <br />COMMISSIONING ITEMS MUST BE COMPLETED FOR EACH DEVICE/LIGHTING CONTROL ZONE: <br />MEASURED LIGHTING POWER (KW) AT THE FULLY DIMMED CONDITION. <br />MEASURED LIGHTING POWER (KW) AT FULL LIGHT OUTPUT. <br />ONLY LIGHTING FIXTURES IN THE DAYLIGHTING ZONE ARE AFFECTED BY THE DAYLIGHTING CONTROLS. <br />LIGHTING POWER IS REDUCED BY AT LEAST 50% IN WINDOW DAYLIT AREAS AND 65% IN SKYLIGHT DAYLIT AREAS. <br />DIMMING SYSTEMS PROVIDE FLICKER FREE OPERATION. <br />ILLUMINATION LEVELS, LOCATIONS OF MEASUREMENTS, SPECIFIC DEVICE SETTINGS ARE DOCUMENTED ON <br />AS-BUILTS. <br />4) <br />WHERE ADDITIONAL 120/ 277 VOLT DEVICES, RECEPTACLES, OR BRANCH CIRCUITS ARE BEING CONTROLLED BY <br />THE ROOM CONTROLLER, AN ADDITIONAL CONTROL UNIT SHALL BE PROVIDED AS REQUIRED. <br />1) <br />2) <br />3) <br />NETWORK SEGMENT MANAGER OR BORDER ROUTER WITH NATIVE BACnet IP - QUANTITY AS REQUIRED BASED <br />UPON A MAXIMUM OF 100 LOCAL ROOM NETWORKS PER SEGMENT AND A MINIMUM OF ONE SEGMENT MANAGER <br />PER FLOOR. THIS EQUIPMENT SHALL BE LOCATED IN THE TYPICAL FLOOR ELECTRICAL ROOM. <br />ALL EQUIPMENT SHALL FEATURE A PRE-SET DEFAULT OPERATION. UPON INITIAL POWER UP, THE SYSTEM SHALL <br />AUTOMATICALLY IDENTIFY THE DEVICES ON THE LOCAL NETWORK, THEN ENTERS THE PRE-SET CONFIGURATION TO <br />ALLOW BASIC OPERATION OF ALL DEVICES. IN MOST APPLICATIONS THE RELATIONSHIP BETWEEN QUANTITY OF <br />LOADS, SWITCHES AND OCCUPANCY SENSORS WILL NOT REQUIRE ANY ADJUSTMENTS - ALTHOUGH AN ADJUSTMENT <br />TO THE AUTOMATIC SETTINGS SHALL BE INCLUDED IN THE BASE BID. <br />ALL EQUIPMENT SHALL FEATURE A CONFIGURATION (CONFIG) BUTTON ON MOST DEVICES THAT ALLOWS EASY ACCESS <br />TO THE INTEGRATED AUTO-CONFIGURATION TECHNOLOGY TO MODIFY SYSTEM OPERATION. FUNCTIONALITY OF THE <br />CONFIG BUTTON SHALL BE STANDARDIZED THROUGHOUT THE PRODUCT LINE, AS IS THE OPERATION OF THE CONFIG <br />LED INDICATORS. <br />GENERAL SYSTEM REQUIREMENTS: <br />b. <br />a. <br />3.ALL PRODUCTS LISTED IN THIS SPECIFICATION ARE BASED UPON PRODUCTS LISTED ON THIS SHEET. THE FEATURES AND <br />CHARACTERISTICS OF THE PRODUCT LITERATURE AND SPECIFICATION SHEETS AVAILABLE ON THE VARIOUS <br />MANUFACTURER'S WEB-SITES ARE INCLUDED IN THE REQUIREMENT OF THESE SPECIFICATIONS. ALL DLCS <br />NETWORKED/NON-NETWORKED SYSTEM-BASED AND STANDALONE COMPONENTS SHALL BE PROVIDED BY A SINGLE <br />MANUFACTURER. <br />e. <br />CONTRACTOR TO UTILIZE THE PHOTOSENSOR AUTOMATIC CALIBRATION AND SETPOINT FUNCTIONS TO ESTABLISH <br />THE OPTIMAL ON/OFF SETPOINTS, TIME DELAYS AND DEADBAND SETTINGS FOR EACH CONTROL ZONE INDICATED <br />WITH DAYLIGHTING CONTROLS. <br />-RAMP UP/DOWN RATES/CUT-OFF TIME DELAY. <br />7) <br />PROVIDE DATA OUTLET/PATHWAY, DATA CABLING (IF REQUIRED ELSEWHERE BY PROJECT DOCUMENTS), AND <br />CONNECTION TO THE PROJECT'S LOCAL AREA NETWORK. <br />3) <br />CONNECT ALL DEVICES AS REQUIRED. UNLESS PROHIBITED BY LOCAL CODE, CONNECTIONS SHALL BE MADE <br />WIRELESSLY OR WITH PLENUM-RATED CABLING ROUTED NEATLY INTO AND ABOVE THE ACCESSIBLE CEILING. CABLES <br />SHALL BE SUPPORTED WITH DEDICATED SUPPORT WIRES AND J-HOOKS. WHERE LOCAL CODE OR PROJECT <br />SPECIFICATIONS REQUIRES LOW VOLTAGE CABLING TO BE ROUTED IN CONDUIT, INCLUDE ALL COSTS IN BASE BID TO <br />PROVIDE APPROPRIATELY-SIZED SYSTEM OF CONDUITS AND JUNCTION BOXES TO ROUTE CONNECTION CABLING. <br />J-BOXES/CONTROLLERS SHALL BE LOCATED ABOVE ACCESSIBLE CEILINGS AND NEVER IN HARD-LID CEILING AREAS. <br />PRE-TERMINATED CABLING SHALL BE PROVIDED BY THE SYSTEM MANUFACTURER AND SHALL BE GREEN IN COLOR <br />UNLESS IT IS ROUTED IN AN EXPOSED CEILING CONDITION WHERE IT SHALL BE BLACK, WHITE OR GRAY AS DIRECTED <br />BY THE ARCHITECT. <br />g. <br />INCLUDE ALL COSTS IN BASE BID TO PROVIDE 120V CIRCUIT(S) AND RECEPTACLE(S) NECESSARY TO POWER ALL <br />NETWORK SEGMENT MANAGERS, SWITCHES AND ROUTERS. <br />i.WHEN LIGHTING SYSTEM IS INDICATED WITH A CONNECTION TO A REMOTE EMERGENCY POWER SOURCE (I.E. AN <br />INVERTER OR GENERATOR) PROVIDE UL924 LISTED INTERFACE EQUIPMENT TO ALLOW THE OVERRIDE OF THE LOCAL <br />SWITCHING AND/OR DIMMING CONTROLS DURING A POWER OUTAGE. <br />2.ALL PRODUCTS SHALL BE BACKED BY A FIVE YEAR MANUFACTURER'S WARRANTY. <br />DAYLIGHT SENSOR SHALL PROVIDE CONTROLS FOR UP TO THREE DISTINCT LIGHTING ZONES TO ALLOW <br />SEPARATE CONTROL OF PRIMARY DAYLIT, SECONDARY DAYLIT, AND SKYLIT ZONES. <br />4) <br />2) <br />WHERE CODE OR LOCAL AHJ REQUIREMENTS REQUIRE THE INSTALLATION OF ALL LOW-VOLTAGE CONDUCTORS TO BE <br />INSTALLED IN CONDUIT - CONTRACTOR TO PROVIDE ALL REQUIRED MANUFACTURER SPECIFIC EQUIPMENT JUNCTION <br />BOXES AND CONDUIT ADAPTERS AS REQUIRED. <br />i. <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />j.WHEN LIGHTING FIXTURES/CONTROLS ARE PROVIDED WITH LUTRON 3-WIRE DIMMING BALLASTS, AN INTERFACE <br />DEVICE SHALL BE PROVIDED TO ALLOW 0-10V CONTROL OF LUTRON 3-WIRE DIMMING BALLASTS. MOUNT INTERFACE IN <br />A NEMA1 ENCLOSURE IN ACCESSIBLE CEILING SPACE ADJACENT TO ITS ASSOCIATED CONTROL UNIT. <br />NETWORK BRIDGE CONNECTING THE SEGMENT MANAGER TO THE CONTROLLER SUB/LOCAL NETWORK. <br />g.WHEN THE PROJECT REQUIRES TWENTY-FIVE (25) OR MORE CEILING MOUNTED SENSORS, CONTRACTOR TO PROVIDE <br />A REMOTE CONTROL PROGRAMMING/CONTROL DEVICE, AND HAND IT TO THE OWNER AT THE END OF THE PROJECT. <br />k.WHEN LIGHTING FIXTURES/CONTROLS ARE LINE VOLTAGE DIMMED OR PROVIDED ELECTRONIC LOW-VOLTAGE, <br />MAGNETIC LOW-VOLTAGE, NEON/COLD CATHODE, LUTRON "TU-WIRE" DIMMING BALLASTS, AN INTERFACE DEVICE <br />SHALL BE PROVIDED TO ALLOW LINE VOLTAGE CONTROL. MOUNT INTERFACE IN A NEMA1 ENCLOSURE IN ACCESSIBLE <br />CEILING SPACE ADJACENT TO ITS ASSOCIATED CONTROL UNIT. <br />THE OCCUPANCY SENSOR CONTROLLED RECEPTACLE BRANCH CIRCUIT RELAY, CONNECTED TO THE SPACE'S <br />DISTRIBUTED LIGHTING CONTROL OCCUPANCY SENSOR RELAY, SHALL TURN ON WHEN THE ROOM IS OCCUPIED, <br />REGARDLESS OF THE CONFIGURATION OF THE LIGHTING CONTROL STATE - I.E. AUTO ON/MANUAL ON. SEE THE <br />DISTRIBUTED LIGHTING CONTROL SPECIFICATION FOR MORE INFORMATION. EVEN THOUGH A SINGLE SYMBOL IS <br />INDICATED, MULTIPLE RELAYS MAY BE REQUIRED TO CONTROL THE REQUIRED NUMBER OF <br />SWITCHLEGS/CIRCUITS. <br />3) <br />LOW VOLTAGE WALL CONTROLS SHALL BE DECORA STYLE, LOW-VOLTAGE, MOMENTARY SWITCHES WITH COLOR <br />TO MATCH OTHER WALL DEVICES/SWITCHES. LOWER CASE LETTERS INDICATE SWITCHING CONFIGURATION. <br />PROVIDE SWITCHING OR DIMMING CONTROL DEVICES AS REQUIRED BY DRAWINGS. <br />DIMMING - NUMBER OF SWITCHES AS REQUIRED - 4 ZONES/YOKE MAX. EACH CONTROL ZONE TO HAVE A <br />DEDICATED RAISE AND LOWER BUTTONS. FACTORY STANDARD COLOR BY ARCHITECT. EACH MULTI-ZONE <br />DIMMING CONTROL STATION SHALL BE PROVIDED WITH MASTER ON AND MASTER OFF BUTTON IN ADDITION TO <br />THE INDIVIDUAL CONTROL ZONE BUTTONS. <br />WHERE INDICATED, PROVIDE A LOCKING SINGLE POLE SWITCH CONNECTED TO THE ROOM CONTROLLER VIA A <br />INPUT/OUTPUT INTERFACE DEVICE FOR ON/OFF CONTROLS. DIRECT CONNECTION OF THE KEYED SWITCH ON THE <br />LOAD SIDE OF THE CONTROLLER IS PROHIBITED. PROVIDE AT LEAST THREE (3) KEYS TO OWNER AT CONCLUSION <br />OF PROJECT. ADJACENT SWITCH SHALL ONLY BRING LIGHTS FULL ON. KEYED SWITCH ALLOWS MANUAL OFF <br />FUNCTIONALITY. DIMMER SWITCH ALLOWS AUTO-ON 50% OVERRIDE TO 100% ALL-ON AND SHALL NOT ALLOW <br />LIGHTING LEVELS TO DECREASE IN ANY WAY. <br />5) <br />6) <br />ALL CORRIDORS, WAREHOUSE AISLE WAYS, AND STAIRWELLS SHALL BE PROVIDED WITH DUAL MODE <br />CORRIDOR/STAIRWAY CONTROLS TO INCLUDE CEC-LISTED TIME CLOCK(S), ROUTERS, OR SYSTEM GATEWAYS, <br />INTERPOSING RELAYS (WHEN INTERFACING WITH EXISTING CEC-LISTED RELAY PANELS), WIRING, 120V POWER, <br />PROGRAMMING, ETC. NECESSARY FOR A COMPLETE AND FUNCTIONING CONTROL SYSTEM. <br />INCLUDE ALL COSTS IN BASE BID TO PROVIDE 120V CIRCUIT(S) AND RECEPTACLE(S) NECESSARY TO POWER ALL <br />DEMAND RESPONSE EQUIPMENT. <br />THE CONTRACTOR TO INCLUDE ALL COSTS TO ENSURE THAT PROGRAMMING IS PERFORMED BY A FACTORY PERSON <br />OR AUTHORIZED TECHNICIAN. FACTORY TECHNICIAN TO ALSO PROVIDE USER/OWNER TRAINING AT TURNOVER OF <br />BUILDING WITH A SECOND TRAINING 60 TO 90 DAYS AFTER OCCUPANCY. TRAINING TO INCLUDE SYSTEM OVERVIEW, <br />TRAINING ON SYSTEM SOFTWARE, PREVENTATIVE MAINTENANCE, SERVICE AND SUPPORT INFORMATION THAT IS <br />DEEMED NECESSARY TO FAMILIARIZE THE OWNER'S PERSONNEL WITH THE OPERATION, USE, MAINTENANCE, <br />ADJUSTMENT, AND PROBLEM SOLVING DIAGNOSIS OF THE OCCUPANCY SENSING DEVICES AND LIGHTING CONTROL <br />SYSTEMS. <br />h. <br />WHERE INDICATED, PROVIDE VANDAL RESISTANT, HIGH ABUSE SWITCH CONNECTED TO THE DLCS INPUT/OUTPUT <br />INTERFACE DEVICE FOR ON/ OFF AND DIMMING CONTROLS. SWITCHES LOCATED IN HIGH ABUSE AREAS <br />(EXTERIOR AREAS OR AREAS SUBJECT TO WASH-DOWN ETC.) OR IDENTIFIED ON PLANS AS HIGH-ABUSE SWITCHES <br />SHALL BE VANDAL RESISTANT, STAINLESS STEEL, TOUCH SENSITIVE AND AVAILABLE WITH UP TO TWO BUTTONS IN <br />A SINGLE GANG. EACH HIGH ABUSE SWITCH SHALL BE ABLE TO BE PROGRAMMED FOR ON, OFF, TOGGLE OR <br />MAINTAIN OPERATION. SWITCHES MUST BE CAPABLE OF HANDLING ELECTROSTATIC DISCHARGES OF AT LEAST <br />30,000 VOLTS (1CMSPARK) WITHOUT ANY INTERRUPTION OR FAILURE IN OPERATION. <br />STANDALONE: WALL MOUNTED OCCUPANCY SENSORS SHALL BE UL LISTED AND HAVE A MINIMUM LOAD CAPACITY OF <br />800 WATTS AT 120 VOLTS AND 1200 WATTS AT 277 VOLTS. WALL SENSORS SHALL ALSO BE DECORA STYLE, WITH A <br />LOW-PROFILE APPEARANCE AND A HARD LENS FOR DURABILITY. SENSOR SHALL UTILIZE PASSIVE INFRARED <br />TECHNOLOGY (PIR) AND ULTRASONIC/MICROPHONIC TECHNOLOGY. UNIT SHALL BE RATED FOR 120/277 VOLT WITH NO <br />MINIMUM LOAD, COMPATIBLE WITH ALL THE SPECIFIED BALLASTS, PROVIDED WITH A NEUTRAL CONNECTION (NO <br />LEAKAGE TO GROUND) AND NO LEAKAGE TO LOAD IN THE "OFF" MODE. SENSOR SHALL BE UTILIZED IN SPACES NOT <br />EXCEEDING 150 SQ.FT. SINGLE RELAY SENSORS SHALL BE CONFIGURED WITH THE RELAY IN A "MANUAL ON/ AUTO <br />OFF" SETTING. DUAL RELAY SENSORS SHALL BE CONFIGURED WITH THE FIRST RELAY IN A "AUTOMATIC ON/ <br />AUTOMATIC OFF" SETTING AND THE SECOND RELAY IN A "MANUAL ON/ AUTOMATIC OFF" SETTING. FACTORY <br />STANDARD COLOR TO BE APPROVED BY ARCHITECT. <br />SYSTEM-BASED (NETWORK OR NON-NETWORK): THE OCCUPANCY SENSOR SYMBOL SHALL REPRESENT A LOW <br />VOLTAGE, WALL MOUNTED OCCUPANCY SENSOR CONNECTED TO A CONTROL UNIT(S) AS REQUIRED. SENSOR SHALL <br />BE DECORA STYLE WITH A LOW-PROFILE APPEARANCE, HAVE ON/OFF/RAISE/LOWER BUTTONS, AND A HARD LENS FOR <br />DURABILITY. FACTORY STANDARD COLOR TO BE APPROVED BY ARCHITECT. <br />d."H" AT THE OCCUPANCY SENSOR INDICATES CONNECTION TO AUXILIARY OUTPUT CONTROL DEVICE FOR CONTROL OF <br />A THIRD PARTY DEVICE VIA LOW-VOLTAGE CONTACT CLOSURES - 1 AMP @ 24V AC/DC. NC/NO RELAYS SHALL BE <br />CONNECTED TO A CONTROLLER TO PERFORM THE AUXILIARY CONTROL REQUIREMENTS INDICATED BY THE <br />DRAWINGS. <br />e.OCCUPANCY SENSORS LOCATED WITHIN CORRIDORS, HALLWAYS, STAIRWAYS/WELLS, AISLEWAYS WITHIN <br />WAREHOUSE SPACES, AND IN OTHER AREAS PER PLANS AND/OR SOO SHALL BE CONFIGURED TO CREATE DUAL MODE <br />CONTROL FUNCTIONALITY PER THE SOO/ZONE SCHEDULE. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL <br />DEVICES AND WIRING REQUIRED FOR DUAL MODE OPERATIONS AND ANY PROGRAMMING/CONFIGURATION OF <br />TIME-BASED OPERATING PARAMETERS. COORDINATE WITH OWNER TO DETERMINE BUSINESS HOUR/AFTER BUSINESS <br />HOUR MODES. IF THE PLANS IDENTIFY A NEW OR EXISTING LIGHTING CONTROL PANEL AS THE SOURCE OF DUAL MODE <br />TIMING, E.C. SHALL INCLUDE ALL COSTS TO INSTALL ANY NECESSARY I/O TERMINALS, CARDS, ETC. TO MAKE THE <br />SYSTEM FULLY FUNCTIONAL. <br />f.NETWORK SYSTEM-BASED DLCS SYSTEMS SHALL PROVIDE/RESULT IN "LADDERLESS COMMISSIONING" OF DAYLIGHT <br />CONTROLS. AT A MINIMUM, NETWORK ACQUIRED DATA SHALL PROVIDE CT-BASED LIGHTING POWER (WATTS) <br />MEASUREMENTS PER THE COMMISSIONING PORTION OF THESE REQUIREMENTS. PROVIDE NETWORKED CONTROL <br />UNITS/POWER PACKS/INTERFACES AND MISCELLANEOUS EQUIPMENT AS FOLLOWS: <br />13. <br />14. <br />INSTALL LINE VOLTAGE CONDUCTORS, LOW VOLTAGE CONDUCTORS AND COMMUNICATIONS CABLING BETWEEN <br />LIGHTING FIXTURES AND DLCS COMPONENTS PER THE DLCS MANUFACTURER'S RECOMMENDATIONS REGARDING <br />CONDUCTOR ROUTING, CONDUCTOR SEPARATION AND CONDUCTOR TERMINATIONS. CONTRACTOR SHALL UTILIZE <br />INSTALLATION MEANS AND METHODS THAT DO NOT COMPROMISE THE DLCS SYSTEM WARRANTY. <br />h. <br />l.WHEN AV SYSTEM INTERFACE IS INDICATED, PROVIDE TWO-WAY CAPABLE RS-232 COMMUNICATIONS INTERFACE TO <br />ALLOW AV CONTROL SYSTEM TO CALL ADDRESSABLE LIGHTING/ROOM SCENES. COMMUNICATIONS INTERFACE SHALL <br />PROVIDE FEEDBACK TO THE AV CONTROL SYSTEM FOR LIGHT LEVEL STATUS. <br />m.WHEN MOVEABLE PARTITION INTERFACE IS INDICATED, PROVIDE ALL COMPONENTS, SENSORS, WIRING, POWER <br />SUPPLIES AND PROGRAMMING NECESSARY TO MONITOR AND REPORT MOVEABLE PARTITION(S) OPEN/CLOSED <br />STATUS. DLCS SYSTEM SHALL AUTOMATICALLY ADOPT SINGLE ROOM OR MULTI-ROOM CONTROL PROFILES AS <br />REQUIRED BY PARTITION STATUS. <br />NETWORK DLCS SYSTEM CONTROL/CONFIGURATION SOFTWARE SHALL BE PRE-CONFIGURED TO THE MAXIMUM <br />EXTENT POSSIBLE OFF-SITE AT THE DLCS FACTORY OR ENGINEERING FACILITY. THE CONTRACTOR SHALL DOCUMENT <br />EVERY NETWORK COMPONENT'S LOCATION (ROOM AND FLOOR NUMBER) AND ITS' RESPECTIVE SERIAL NUMBER OR <br />OTHER DEVICE IDENTIFIER ON A FULL SIZE FLOOR PLAN IN PDF FORMAT. HANDWRITTEN DOCUMENTATION IS <br />UNACCEPTABLE. THE PREFERRED ACCEPTABLE METHOD OF NETWORK COMPONENT DOCUMENTATION IS COLLECTION <br />OF FACTORY-PROVIDED, SELF-ADHESIVE, BAR-CODE IDENTIFIERS DESIGNED TO BE REMOVED FROM NETWORK <br />COMPONENTS AS THEY ARE INSTALLED IN THE FIELD. BAR CODES IDENTIFIERS SHALL BE APPLIED TO A PAPER COPY <br />OF A FLOOR PLAN WHICH SHALL BE PROVIDED TO THE FACTORY FOR USE IN OFF-SITE DLCS NETWORK PROGRAMMING <br />AND CONFIGURATION. THE RESULTS OF EITHER METHOD SHALL BE SCANNED AND SUBMITTED AS A PART OF THE <br />PROJECT CLOSEOUT DOCUMENTATION. <br />c. <br />n.WHEN NETWORKED LIGHTING CONTROL RELAY PANEL(S) ARE INDICATED, PROVIDE ALL COMPONENTS, WIRING, AND <br />PROGRAMMING NECESSARY TO INTEGRATE RELAY PANELS WITHIN THE DLCS SYSTEM. <br />NETWORK SYSTEMS SHALL BE INSTALLED BY VENDOR-CERTIFIED CONTRACTOR FIELD PERSONNEL TO PERFORM <br />NETWORK INSTALLATIONS INCLUDING ACCURATE, REPEATABLE COMMUNICATIONS CABLING TERMINATIONS (BOTH LAN <br />AND MS/TP TYPE). INCLUDE CERTIFICATES FOR EACH CERTIFIED INSTALLER TO BE UTILIZED ON THE PROJECT AS A <br />PART OF THE PROJECT SUBMITTALS. A CERTIFIED FIELD INSTALLER SHALL BE ON-SITE SUPERVISING <br />COMMUNICATIONS CABLING AND CABLING TERMINATIONS AT ALL TIMES WHEN THIS WORK IS OCCURRING ON THE <br />PROJECT. <br />d. <br />UNLESS PROHIBITED BY LOCAL CODE, ALL CONTROL UNITS SHALL BE PLENUM-RATED. WHERE CONTROL UNITS ARE <br />LOCATED IN EXPOSED CEILING SPACES, INCLUDE ALL COSTS IN BASE BID TO PROVIDE APPROPRIATELY-SIZED <br />VENTILATED CONTROL UNIT ENCLOSURES FOR CONCEALMENT. COLOR OF ENCLOSURE PER ARCHITECT. <br />j. <br />SYSTEM-BASED (NETWORK OR NON-NETWORK) OR STANDALONE CEILING MOUNTED OCCUPANCY SENSORS SHALL <br />SHALL REPRESENT A LOW VOLTAGE, CEILING-MOUNTED OCCUPANCY SENSOR WITH A LOW-PROFILE APPEARANCE AND <br />SHALL BE CONFIGURED IN ONE OF THE FOLLOWING WAYS AS INDICATED ON THE DRAWINGS: <br />- AUTO ON: a/b <br />- SWITCHED: AUTO ON a / MANUAL ON b <br />- CONTINUOUS DIMMED: AUTO ON 50% a / MANUAL ON 100% a <br />SENSOR(S) SHALL UTILIZE DUAL TECHNOLOGY (PIR AND ULTRASONIC/MICROPHONIC TECHNOLOGY) WITH 360 DEGREE <br />COVERAGE. IN SPACES WITH DESKTOP ACTIVITIES, THE COVERAGE SHALL BE "HAND MOTION" AND SHALL NOT EXCEED <br />500 SQ. FT. AT A MAXIMUM CEILING HEIGHT OF 10 FT. IN CORRIDORS, STORAGE ROOMS AND OTHER SPACES WITH <br />NON-DESKTOP ACTIVITIES, COVERAGE SHALL BE "HALF-STEP, WALKING MOTION" AND SHALL NOT EXCEED 1200 SQ. FT. <br />AT A MAXIMUM CEILING HEIGHT OF 10 FT. PIR-ONLY WIRELESS OCCUPANCY SENSORS SHALL NOT BE UTILIZED IN <br />RESTROOMS OR LOCKER ROOMS. <br />DEMONSTRATE DLCS RESPONSE TO A SIMULATED DEMAND RESPONSE REQUEST AS PART OF THE LIGHTING <br />COMMISSIONING PROCESS. WHERE MORE THAN ONE WIRING TOPOLOGY AND/OR ZONE IS REQUIRED TO <br />ACCOMPLISH DEMAND RESPONSE - ALL WIRING TOPOLOGIES AND ZONES SHALL BE TESTED ACCORDINGLY. SEE <br />DLCS SOO FOR POWER REDUCTION PERCENTAGES BY ROOM TYPE THAT SHALL BE UTILIZED IN THE SIMULATED <br />DEMAND RESPONSE TESTING. <br />4) <br />1. <br />DEMAND RESPONSE TESTING, RECORDING, PRE-TEST, "OCCUPIED" STEADY-STATE LIGHTING POWER (KW) & <br />SIMULATED DEMAND RESPONSE LIGHTING POWER (KW) DEMONSTRATING AN OVERALL 10% ENERGY REDUCTION. <br />- <br />15. <br />d. <br />a.PRIOR TO NETWORK SYSTEM FACTORY START-UP, THE CONTRACTOR SHALL 1) TEST ALL COMMUNICATIONS CABLING <br />FOR SHORTS, POLARITY REVERSALS AND BAD TERMINATIONS/CONNECTIONS AND MAKE NECESSARY REPAIRS AND 2) <br />DEMONSTRATE FULL CONNECTIVITY TO ALL NETWORK AND LOCAL (IN-ROOM) DEVICES VIA MS/TP CAPTURE OR OTHER <br />VENDOR SPECIFIC TESTING PROCESS. CONTRACTOR SHALL PROVIDE A TEST REPORT OUTLINING TEST COMPLETION <br />AND ANY REPAIRS MADE AND CERTIFY THAT NETWORK DEVICE AND LOCAL DEVICE CONNECTIVITY HAS BEEN <br />ACHIEVED PRIOR TO SCHEDULED FACTORY START-UP. BASED ON PAST PROJECT EXPERIENCE, FAILURE TO PERFORM <br />ANY OF THE ABOVE STEPS HAS RESULTED IN BOTH VERY INEFFICIENT FACTORY START-UP AND PROJECT DELIVERY <br />DELAY. ANY ADDITIONAL COSTS ARISING OUT OF A FAILURE TO COMPLETE THIS TESTING SHALL BE BORNE SOLELY BY <br />THE CONTRACTOR. <br />DLCS START-UP, BUILDING AUTOMATION SYSTEM (BAS) INTEGRATION, COMMISSIONING, & TRAINING <br />NETWORK SYSTEMS SHALL BE INSPECTED, STARTED UP, CONFIGURED AND PROGRAMMED BY FACTORY START-UP <br />TECHNICIANS TO MEET THE INTENDED INTEGRATION AND CONTROLS SCENARIOS AND FUNCTIONALITY DESIRED BY <br />THE SYSTEM USER. EFFORT SHALL INCLUDE REQUESTING ANY END-USER SPECIFIC NETWORK ADDRESSING OR OTHER <br />INSTRUCTIONS FOR THE DLCS TO RESIDE ON THE END-USER LAN. FOR PROJECTS WHERE THE END-USER DOES NOT <br />WANT THE DLCS TO COMMUNICATE WITH THE END-USER LAN, CONTRACTOR SHALL PROVIDE AND CONFIGURE ALL <br />DLCS NETWORK COMPONENTS AS REQUIRED FOR THE SYSTEM TO FUNCTION IN ISOLATION WITHOUT PERMANENT LAN <br />OR INTERNET ACCESS. <br />b. <br />WHERE THE DLCS SCHEDULE INDICATES BAS INTEGRATION IS REQUIRED OR WHERE REQUIRED PER MECHANICAL & <br />MECHANICAL CONTROLS DRAWINGS AND SPECIFICATIONS, THE CONTRACTOR'S DLCS FACTORY TECHNICIAN SHALL <br />ASSIST THE BAS CONTRACTOR WITH DLCS POINT INTEGRATION. THE PRIMARY OBJECTIVE OF DLCS INTEGRATION WITH <br />THE BAS IS TO ALLOW FOR OCCUPANCY-BASED HVAC SETBACK, TO ENABLE/CONTROL LIGHTING SCHEDULES AND TO <br />INTEGRATE ZONE OR AREA OCCUPANCY LIGHTING STATUS INTO A BAS GRAPHICAL USER INTERFACE DISPLAY BASED <br />ON ARCHITECTURAL FLOOR PLAN(S). SECONDARY OBJECTIVES INCLUDE; REMOTE TROUBLESHOOTING OF USER <br />COMPLAINTS, INTEGRATION INTO FUTURE CONTINUOUS COMMISSIONING SYSTEMS ETC AND AS OUTLINED IN THE <br />MECHANICAL CONTROLS DRAWINGS AND SPECIFICATIONS AND AS FOLLOWS: <br />c. <br />THE PRIMARY PROTOCOL FOR INTEGRATION SHALL BE BACNET PER ANSI/ASHRAE 135-2016 – OR LATEST <br />PUBLISHED STANDARD. <br />1) <br />WHERE A DLCS NETWORK COMPONENT IS BTL (BACNET TESTING LAB)-LISTED, IT SHALL BE LABELED AS SUCH. <br />WHERE A DLCS NETWORK COMPONENT IS FOUND TO CAUSE BACNET INTEGRATION ISSUES, THE DLCS <br />MANUFACTURER SHALL BE RESPONSIBLE FOR ALL COSTS RELATED TO BOTH TROUBLESHOOTING THE ISSUE AND <br />THE ULTIMATE RESOLUTION OF THE ISSUE TO INCLUDE COSTS ASSOCIATED WITH USE OF BACNET PROTOCOL <br />ANALYZERS TO IDENTIFY THE PROBLEM UP TO AND INCLUDING LABOR, MATERIAL, EQUIPMENT, SOFTWARE <br />CODING, FIRMWARE REVISIONS, AND RECOMMISSIONING ASSOCIATED WITH REPAIR, REPLACEMENT AND/OR <br />ADDITIONAL COMPONENTS NEEDED TO CORRECT THE INTEGRATION ISSUE. <br />2) <br />THE DLCS NETWORK SHALL BROADCAST ANY OCCUPANCY SENSOR STATUS VIA CHANGE OF VALUE TO THE BAS IN <br />LESS THAN 5 SECONDS. POLLING BY THE DLCS AS A METHOD OF OBTAINING OCCUPANCY SENSOR VALUES IS <br />UNACCEPTABLE DUE TO EXCESSIVE LATENCY AND RESULTANT SLOW SYSTEM RESPONSE TIME. <br />3) <br />WHILE THE DLCS SHALL BE CAPABLE OF PROVIDING A MUCH LARGER VARIETY OF BACNET POINTS, THE <br />FOLLOWING ARE REQUIRED FOR BASIC INTEGRATION AT A MINIMUM (SEE MECHANICAL DRAWINGS AND <br />SPECIFICATIONS FOR SPECIFIC POINT INTEGRATION REQUIREMENTS): <br />4) <br />INTERIOR DLCS POINTS- <br />ROOM OCCUPANCY STATE: REPORTS OCCUPIED VS UNOCCUPIED.-- <br />INDIVIDUAL OCCUPANCY SENSOR STATE: REPORTS OCCUPIED VS UNOCCUPIED AREA(S).-- <br />LOAD/RELAY STATE: REPORTS LIGHT FIXTURE ON /OFF STATUS.-- <br />LOAD DIMMING LEVEL: REPORTS AUTOMATIC OR MANUAL DIMMING STATUS.-- <br />DAYLIGHT SENSOR INHIBITING: REPORTS DAY LIGHT SENSOR HOLDING LIGHTS AT A DIMMED LEVEL.-- <br />ROOM SCHEDULE STATE: REPORTS NORMAL VS AFTER HOURS SCHEDULE MODE.-- <br />EXTERIOR DLCS POINTS- <br />RELAY PANEL SCHEDULE STATE: REPORTS NORMAL VS AFTER HOURS SCHEDULE MODE.-- <br />INDIVIDUAL RELAY STATE: REPORTS LIGHT FIXTURE ZONE ON /OFF STATUS.-- <br />ALL OF THE ABOVE POINTS, USING THE OBJECT NAMING SCHEME PROVIDED BY THE MECHANICAL CONTROLS/BAS <br />CONTRACTOR, SHALL BE PROVIDED TO THE BAS CONTRACTOR IN AN ELECTRONIC TABLE FORMAT TO INCLUDE; <br />BACNET OBJECT NAME, OBJECT SERIAL NUMBER, ROOM NAME AND NUMBER FOR EACH DEVICE ON THE PROJECT. <br />FOR RELAY PANEL-BASED OBJECTS, PROVIDE ROOM NAMES OR EXTERIOR LIGHTING ZONE NAMES AS <br />APPROPRIATE. PROVIDE BUILDING NUMBER FOR EACH DEVICE WHERE THE PROJECT CONSISTS OF MORE THAN <br />ONE BUILDING. SEE MECHANICAL CONTROLS DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL FORMATTING <br />REQUIREMENTS. <br />5)A PROJECT-SPECIFIC BACNET OBJECT NAMING PROTOCOL SHALL BE DEVELOPED AND PROVIDED BY THE <br />MECHANICAL CONTROLS/BAS CONTRACTOR TO BE USED BY THE DLCS CONTRACTOR IN NAMING DLCS BACNET <br />OBJECTS INTEGRATED INTO THE BAS. CONFIRM DLCS ADDRESSING/OBJECT NAMING SCHEME WITH MECHANICAL <br />CONTROLS/BAS CONTRACTOR PRIOR TO IMPLEMENTING IN ORDER TO REDUCE INTEGRATION CONFLICTS. <br />6) <br />IN ADDITION TO A POINTS LIST TABLE, PROVIDE A SHOP DRAWING DEPICTING; THE LOCATION OF EACH <br />OCCUPANCY AND DAYLIGHT SENSOR AND EACH SENSOR OBJECT NAME. WHERE RELAY PANELS ARE PROVIDED, <br />ALSO INDICATE EACH INTERIOR AND EXTERIOR RELAY PANEL ZONE CONTROL AREA. <br />7) <br />INCLUDE SUFFICIENT MEETING AND COORDINATION EFFORT WITH THE BAS AND MECHANICAL CONTRACTORS TO <br />REVIEW THE ABOVE INFORMATION. WHERE OCCUPANCY SENSOR ZONES DO NOT CORRESPOND TO HVAC <br />VARIABLE AIR VOLUME (VAV) ZONES, EC/DLCS VENDOR SHALL ASSIST THE BAS AND MECHANICAL CONTRACTORS <br />IN RESOLVING THE CONFLICT THROUGH TROUBLESHOOTING DEVICE/OBJECT NAMING SCHEMES. <br />8) <br />ANY BATTERY-POWERED DLCS COMPONENTS SHALL BE PROVIDED WITH A 10 YEAR EXPECTED BATTERY LIFE. EACH <br />COMPONENT SHALL BE PROVIDED WITH BOTH A LOCAL LOW BATTERY INDICATION ON EACH DEVICE AND A <br />SOFTWARE-BASED LOW BATTERY ALARM. WHERE A WIRELESS DLCS SYSTEM COMPONENT IS AVAILABLE EITHER AS A <br />BATTERY POWERED DEVICE OR A LINE/LOW VOLTAGE POWERED DEVICE, PROVIDE THE LINE/LOW VOLTAGE VERSION <br />ALONG WITH ANY LINE OR LOW VOLTAGE WIRING, CONDUIT AND BACK BOXES TO LIMIT THE NUMBER OF BATTERIES <br />WITHIN THE DLCS INSTALLATION TO A MINIMUM. <br />e. <br />4.DLCS COMPONENTS SHALL BE COMPLIANT WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL ENERGY CODES. <br />5.ALL NETWORKED AND NON-NETWORKED SYSTEM-BASED DLCS SYSTEMS SHALL BE COMPLIANT WITH AND CERTIFIED TO <br />THE FOLLOWING SECURITY STANDARDS SET FORTH IN THE LATEST PUBLISHED VERSION OF THE DESIGNLIGHTS <br />CONSORTIUM'S "NETWORKED LIGHTING CONTROL SYSTEM TECHNICAL REQUIREMENTS" DOCUMENT (VERSION 4.0 OR <br />LATEST PUBLISHED VERSION): <br />"NETWORKED" - <br />WHERE THE DLCS SCHEDULE INDICATES A SPECIFIC "SYSTEM TOPOLOGY" OPTION, PROVIDE ONE OF THE FOLLOWING:6. <br />"NON-NETWORKED" - <br />PROVIDE A SYSTEM-BASED DLCS THAT COMMUNICATES USING A MANUFACTURER-SPECIFIC DLCS <br />NETWORK ALLOWING BI-DIRECTIONAL FLOW OF INFORMATION BETWEEN DEVICES SUCH AS ROOM <br />CONTROLLERS, SENSORS, RELAY PANELS AND NETWORK CONTROLLERS. PROVIDE A DLCS GUI <br />AND RELATED SOFTWARE TO FACILITATE REMOTE DLCS DEVICE PARAMETERS CHANGES, <br />REMOTE CONTROL ANY DLCS ELEMENT OR DEVICE, REMOTE SCHEDULE <br />CHANGES/IMPLEMENTATIONS, AND REMOTE DLCS COMMISSIONING AND TROUBLESHOOTING. A <br />NETWORKED SYSTEM TOPOLOGY SHALL BE CONFIGURED TO RESPOND TO LOCAL UTILITY <br />DEMAND RESPONSE SIGNALS. <br />"STAND ALONE" - <br />PROVIDE A SYSTEM-BASED DLCS THAT COULD BE MADE TO COMMUNICATE USING A <br />MANUFACTURER-SPECIFIC DLCS NETWORK, BUT FOR THIS PROJECT IS CONFIGURED WITHOUT <br />ANY NETWORK CONNECTIVITY OR NETWORK COMPONENTS, EXCEPT FOR ANY NETWORK <br />COMPONENTS REQUIRED FOR DUAL MODE CONTROL FOR CORRIDORS, WAREHOUSE AISLES ETC <br />OR WHERE REQUIRED FOR BAS INTEGRATION REQUIRED IN THE DLCS SCHEDULE OR ELSEWHERE <br />IN THE DRAWINGS AND SPECIFICATIONS. IN A "NON-NETWORKED" DLCS, DEMAND RESPONSE <br />CAPABILITY IS NOT REQUIRED. <br />PROVIDE INDIVIDUAL WALL SENSORS/CONTROLS - OPERATING AT 120V OR 277V. GENERALLY, <br />STANDALONE COMPONENT INSTALLATIONS ARE TO BE AVOIDED AND ARE LIMITED TO USE IN <br />SMALL ROOMS WHERE ADVANCED CONTROLS, DIMMING CAPABILITY, DEMAND RESPONSE, DUAL <br />MODE CONTROL AND/OR NETWORK CONNECTIVITY ARE NOT REQUIRED BY APPLICABLE ENERGY <br />CODE AND WHERE ACCEPTABLE TO AN END-USER. <br />"WIRED" - <br />WHERE THE DLCS SCHEDULE INDICATES A SPECIFIC "COMMUNICATIONS TOPOLOGY" OPTION, PROVIDE ONE OF THE <br />FOLLOWING: <br />7. <br />"WIRELESS" - <br />PROVIDE WIRING, AS REQUIRED, TO INTERCONNECT DLCS DEVICES. WIRING MAY BE A COMBINATION OF <br />LOW AND LINE VOLTAGE CONDUCTORS BASED ON SPECIFIC MANUFACTURER REQUIREMENTS. <br />"HYBRID" - <br />PROVIDE WIRELESS CONNECTIVITY BETWEEN WALL CONTROLS, WALL, CEILING OR <br />FIXTURE-INTEGRATED SENSORS, ROOM CONTROLLERS, WIRELESS ROUTER(S), AND WIRELESS <br />NETWORK BRIDGES. CONTRACTOR SHALL PROVIDE WIRELESS ROUTERS, QTY AS REQUIRED, TO <br />MAINTAIN ROBUST COMMUNICATIONS WITH ALL WIRELESS DEVICES. ROBUST MEANS THAT A CHANGE <br />OF VALUE FROM OR TO ANY DLCS SYSTEM COMPONENT FROM OR TO AN APPLICABLE WIRELESS <br />ROUTER/BRIDGE OCCURS IN LESS THAN 3 SECONDS. <br />WHERE A SOLELY WIRELESS DLCS TOPOLOGY IS DEEMED INADEQUATE BASED ON OPERATIONAL OR <br />AESTHETIC REASONS, A WIRELESS TOPOLOGY SHALL BE AUGMENTED WITH WIRED SYSTEM TO FORM A <br />HYBRID COMMUNICATIONS TOPOLOGY. AREAS REQUIRING WIRED CONNECTIVITY SHALL BE OUTLINED <br />ON THE LIGHTING PLANS AND UNLESS OTHERWISE INDICATED, ALL RESTROOMS SHALL BE PROVIDED <br />WITH DUAL TECHNOLOGY OCCUPANCY SENSORS WHICH REQUIRE WIRED CONNECTIVITY AND WIRED <br />POWER SUPPLY. A NETWORKED, SYSTEM-BASED DLCS INSTALLED WITH A HYBRID COMMUNICATIONS <br />TOPOLOGY SHALL APPEAR IN THE USER GUI/SOFTWARE AS A SINGLE UNIFIED SYSTEM. SEPARATE GUI <br />SOFTWARE INTERFACES FOR THE WIRED AND WIRELESS PORTIONS OF THE DLCS ARE UNACCEPTABLE. <br />WHERE THE DLCS SCHEDULE REQUIRES FIXTURE-INTEGRATED SENSORS, PROVIDE OCCUPANCY AND/OR DAYLIGHT <br />SENSORS INTEGRATED WITHIN SPECIFIED FIXTURE TYPE THAT ALSO INTEGRATE INTO THE DLCS. SEE THE LIGHTING <br />FIXTURE SCHEDULE FOR AFFECTED FIXTURE TYPE(S). WHERE INTEGRATED SENSORS DO NOT MEET <br />OCCUPANCY/DAYLIGHT SENSOR COVERAGE REQUIREMENTS, CONTRACTOR SHALL AUGMENT COVERAGE WITH ADDITIONAL <br />CEILING MOUNTED SENSORS AS REQUIRED AND AS A PART OF THE BASE BID. <br />9. <br />WHERE THE DLCS SCHEDULE REQUIRES THE DLCS TO INTEGRATE WITH THE PROJECT'S BUILDING AUTOMATION SYSTEM <br />(BAS) - SEE THE DLCS START-UP, BUILDING AUTOMATION SYSTEM (BAS) INTEGRATION, COMMISSIONING, & TRAINING <br />PORTION OF THIS SPECIFICATION FOR ADDITIONAL REQUIREMENTS. <br />10. <br />ADDITIONALLY, WHERE INSTALLED IN THE STATE OF CALIFORNIA, SYSTEM-BASED DLCS SYSTEMS SHALL BE COMPLIANT <br />WITH CA STATE ASSEMBLY BILL NO. 375 CALIFORNIA PRIVACY ACT OF 2018 AND CA STATE SENATE BILL NO 327 <br />INFORMATION PRIVACY FOR CONNECTED DEVICES. <br />DLCS COMPONENTS: UL2900-1 UL STANDARD FOR SOFTWARE CYBER SECURITY FOR NETWORK-CONNECTABLE <br />PRODUCTS. <br />DLCS DESIGN PROCESS: UL 2900-1 UL STANDARD FOR SOFTWARE CYBER SECURITY FOR NETWORK- CONNECTABLE <br />PRODUCTS AND/OR ISO/IEC 27001 STANDARD FOR INFORMATION SECURITY MANAGEMENT SYSTEMS. <br />DLCS CLOUD SERVICES: ANY ASSOCIATED DLCS CLOUD SERVICES SHALL MEET THE REQUIREMENTS OF ISO/IEC <br />27017 (WITH 27001) STANDARD FOR CODE OF PRACTICE FOR INFORMATION SECURITY CONTROLS FOR CLOUD <br />SERVICES. <br />c. <br />aa,ba,b,ca,b,c,d <br />ON <br />RAISE <br />OFF <br />LOWER <br />ALL <br />ON <br />ALL <br />OFF <br />RAISE LOWER <br />ALL <br />ON <br />ALL <br />OFF <br />RAISE LOWER <br />BLANK BLANK <br />RAISE LOWER <br />ALL <br />ON <br />ALL <br />OFF <br />RAISE LOWER <br />RAISE LOWER <br />RAISE LOWER <br />RAISE LOWER <br />RAISE LOWER <br />RAISE LOWER <br />SYMBOLS / REPRESENTATIVE GRAPHIC IMAGES <br />KaLLLLL <br />OFF <br />ON <br />FULL <br />ON <br />WHERE THE MANUFACTURER CANNOT DEMONSTRATE COMPLIANCE WITH THE ABOVE REQUIREMENTS, THE DLCS <br />MANUFACTURER SHALL PROVIDE A COMPREHENSIVE PRODUCT-SPECIFIC IT SECURITY STATEMENT FOR REVIEW BY THE <br />OWNER. THE DLCS SHALL NOT BE CONNECTED TO AN OWNER-FURNISHED NETWORK WITHOUT PRIOR WRITTEN PERMISSION <br />BY THE OWNER, <br />WHERE THE DLCS SCHEDULE INDICATES "WIRELESS" OR "HYBRID" COMMUNICATIONS TOPOLOGIES AND ALSO ALLOWS <br />WIRELESS DLCS COMPONENT BATTERY USAGE, PROVIDE BATTERIES WITHIN THE WIRELESS DLCS COMPONENTS INDICATED <br />IN LIEU OF LINE OR LOW VOLTAGE POWER SOURCES. <br />11. <br />- <br />- <br />- <br />21159.00 <br />1202 W Edinger <br />Ave10/3/2024