Laserfiche WebLink
Page <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />: <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />N <br />a <br />m <br />e <br /> <br />3. <br />5 <br />2 <br />0 <br /> <br />k <br />W <br /> <br />( <br />D <br />C <br />) <br /> <br />/ <br /> <br />3 <br />. <br />2 <br />0 <br />2 <br /> <br />k <br />W <br /> <br />( <br />C <br />E <br />C <br />- <br />A <br />C <br />) <br /> <br />PH <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br /> <br />12 <br />1 <br />0 <br /> <br />E <br /> <br />A <br />V <br />A <br />L <br />O <br />N <br /> <br />A <br />V <br />E <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br /> <br />- <br />AD <br />U <br />12 <br />1 <br />0 <br /> <br />E <br /> <br />A <br />V <br />A <br />L <br />O <br />N <br /> <br />A <br />V <br />E <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />AP <br />N <br />: <br /> <br />3 <br />9 <br />6 <br />1 <br />9 <br />1 <br />0 <br />7 <br />DA <br />T <br />E <br />: <br /> <br />06 <br />/ <br />1 <br />1 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />DR <br />A <br />W <br />N <br /> <br />B <br />Y <br />: <br /> <br />RD <br /> <br />Co <br />n <br />t <br />r <br />a <br />c <br />t <br />o <br />r <br />s <br /> <br />S <br />i <br />g <br />n <br />a <br />t <br />u <br />r <br />e <br />: <br /> <br />PR <br />E <br />M <br />I <br />E <br />R <br /> <br />B <br />U <br />I <br />L <br />D <br />E <br />R <br />S <br /> <br />& <br /> <br />H <br />A <br />R <br />D <br />S <br />C <br />A <br />P <br />E <br /> <br />I <br />N <br />C <br /> <br />88 <br />3 <br />2 <br /> <br />L <br />A <br /> <br />G <br />R <br />A <br />N <br />D <br /> <br />A <br />V <br />E <br /> <br />GA <br />R <br />D <br />E <br />N <br /> <br />G <br />R <br />O <br />V <br />E <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />4 <br />1 <br /> <br />PH <br />O <br />N <br />E <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />4 <br />6 <br />7 <br />- <br />9 <br />0 <br />1 <br />8 <br />LI <br />C <br />E <br />N <br />S <br />E <br />: <br /> <br /># <br />9 <br />9 <br />5 <br />0 <br />6 <br />8 <br />/ <br />B <br />, <br />C <br />5 <br />3 <br /> <br />R1 <br /> <br />0 <br />6 <br />. <br />1 <br />3 <br />. <br />2 <br />4 <br />( <br />T <br />Y <br />) <br />CO <br />V <br />E <br />R <br /> <br />P <br />A <br />G <br />E <br /> <br />1A OF 11 <br />PHOTOVOLTAIC GENERAL NOTES <br />· ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK PERFORMED SHALL <br />BE IN ACCORDANCE WITH THE FOLLOWING CODES: <br />- 2022 CBC / 2021 IBC <br />- 2022 CRC / 2021 IRC <br />- 2022 CEC / 2020 NEC <br />- 2022 CMC / 2021 IMC <br />- 2022 CPC / 2021 IPC <br />- 2022 CFC / 2021 IFC <br />- 2022 BUILDING ENERGY EFFICIENCY STANDARDS <br />· ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED <br />ELECTRICAL TESTING LABORATORY AND L.A. TEST LAB. EQUIPMENT <br />INSTALLED SHALL BE PER ITS LISTING REQUIREMENTS AND THE <br />MANUFACTURER'S INSTRUCTIONS. NEC 110.2, 110.3, 690.4(B), 690.12(D). <br />· ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF <br />MOUNTED TRANSITION BOXES AND SWITCHES. <br />· ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN <br />ACCORDANCE WITH NEC ARTICLE 250. <br />· PV SYSTEM DC CIRCUIT AND INVERTER OUTPUT CONDUCTORS AND <br />EQUIPMENT SHALL BE PROTECTED AGAINST OVERCURRENT. CIRCUITS <br />SIZED IN ACCORDANCE WITH 690.8(A)(2) ARE REQUIRED TO BE PROTECTED <br />AGAINST OVERCURRENT PROTECTIVE DEVICES. EACH CIRCUIT SHALL BE <br />PROTECTED FROM OVERCURRENT IN ACCORDANCE WITH 690.9(A)(1), (A)(2), <br />OR (A)(3). [NEC 690.9(A)] <br />· DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN <br />INITIATION) SHALL BE LOCATED IN A READILY ACCESSIBLE LOCATION WITHIN <br />THE EQUIPMENT, WITHIN SIGHT OF THE EQUIPMENT, OR REMOTELY WHERE <br />THE EQUIPMENT DISCONNECTING MEANS. [NEC 690.13(A), 690.15] <br />· RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH NEC 690.12. <br />· ENERGY STORAGE SYSTEM DISCONNECTING MEANS SHALL BE PROVIDED <br />FOR ALL UNGROUNDED CONDUCTORS AND SHALL BE READILY ACCESSIBLE <br />AND WITHIN LINE OF SIGHT; WHERE PARTITIONED, AN ADDITIONAL <br />DISCONNECT SHALL BE PROVIDED WITHIN SIGHT OF THE ESS COMPONENT. <br />OVERCURRENT PROTECTION SHALL BE PROVIDED. [706.15, 706.31] <br />· UPON LOSS OF PRIMARY SOURCE, THE OUTPUT OF ELECTRIC POWER <br />PRODUCTION EQUIPMENT SHALL BE AUTOMATICALLY DISCONNECTED FROM <br />ALL UNGROUNDED CONDUCTORS OF THE INTERCONNECTED SYSTEMS. THE <br />ELECTRIC POWER PRODUCTION EQUIPMENT SHALL NOT BE RECONNCETED <br />UNTIL ALL PHASES OF THE PRIMARY SOURCE IS RESTORED. [NEC 705.40] <br />· ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND <br />IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND FOR THE APPLICATION. [NEC <br />690.31(C) THROUGH (F), 310.10(D)] <br />· EXPOSED CONDUCTORS WITHIN THE PV ARRAY SHALL BE PV WIRE/CABLE, <br />OR TYPE USE-2, OR TYPE RHW-2 (UL 4703 & 854 LISTED) [NEC 690.31(C)(1)] <br />· FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND <br />TERMINALS TO ENSURE A THOROUGHLY GOOD CONNECTION WITHOUT <br />DAMAGING THE CONDUCTORS. [NEC 110.14(A)] <br />· FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH <br />TERMINALS, LUGS, DEVICES, OR CONNECTORS THAT ARE IDENTIFIED AND <br />LISTED FOR SUCH USE. [NEC 690.31(C)(5), 110.14] <br />· ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND <br />GROUPED FOR UNIQUE IDENTIFICATION. [NEC 690.31(B)] <br />· ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN TIGHT AND <br />APPROVED FOR USE IN WET LOCATIONS. (NEC 314.15) <br />· ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID <br />WHITE, GRAY, OR WITH 3-WHITE STRIPES. [NEC 200.6, 200.7, 400.22]; ALL <br />GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, <br />OR WITH INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, NEC <br />250.119 & 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE <br />OTHER THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS. <br />[NEC 310.110(C)] <br />· MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND <br />OVERCURRENT PROTECTION IS 10FT IN DWELLING UNITS AND 16.5FT IN OTHER <br />THAN DWELLING UNITS FROM THE POINT OF CONNECTION TO THE SERVICE. <br />[NEC 705.11(C)] <br />· CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF <br />THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES <br />SHALL BE IN ACCORDANCE WITH NEC 705.12(B). <br />· DC WIRING INSIDE A BUILDING MUST BE IN METAL RACEWAYS, METAL-CLAD CABLE, <br />OR METAL ENCLOSURES. [NEC 690.31(D)] <br />· METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS <br />CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND MUST BE BONDED IN <br />ACCORDANCE WITH NEC 250.97. <br />· CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE <br />READILY ACCESSIBLE AND OPERATING AT OVER 30-VOLTS SHALL REQUIRE A TOOL <br />TO OPEN AND MARKED "DO NOT DISCONNECT UNDER LOAD" OR "NOT FOR <br />CURRENT INTERRUPTING." [NEC 690.33(C) & (D)(2)] <br />· EQUIPMENT GROUNDING CONDUCTOR (EGC) SMALLER THAN #6-AWG SHALL BE <br />PROTECTED FROM PHYSICAL DAMAGE BY AN IDENTIFIED RACEWAY OR CABLE <br />ARMOR, UNLESS INSTALLED WITHIN HOLLOW SPACES OF THE FRAMING MEMBERS <br />OF BUILDINGS OR STRUCTURES AND WHERE NOT SUBJECT TO PHYSICAL DAMAGE. <br />[NEC 250.120(C)] <br />· THE INTERCONNECTION POINT SHALL BE ON THE SUPPLY SIDE OF ALL <br />GROUND-FAULT PROTECTION EQUIPMENT. [NEC 705.32] <br />· CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT <br />LOCATED UNDER THE MODULES, MUST BE PROTECTED. [NEC 300.4] <br />· FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF <br />NATURAL GAS, HOT WATER, AND COLD WATER MUST BE PROVIDED. [NEC 250.104] <br />· GROUNDING ROD ELECTRODES SHALL BE INSTALLED 8-FT MINIMUM IN CONTACT <br />WITH SOIL AND MINIMUM 5/8-INCH DIAMETER. [NEC 250.52(A)(5), 250.53(G)] <br />· THE MARKINGS, "PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS AND CABLE <br />ASSEMBLIES MUST BE NO MORE THAN 10-FT O.C.; AND IS SEPARATED BY <br />ENCLOSURES, WALLS, PARTITIONS, CEILINGS, FLOORS, OR BENDS ABOVE OR <br />BELOW PENETRATIONS. [NEC 690.31(D)(2)] <br />· WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL <br />EQUIPMENT. [NEC 110.26] <br />· POWER PRODUCTION SYSTEMS, AND ALL ASSOCIATED WIRING AND <br />INTERCONNECTIONS OPERATING IN PARALLEL WITH A PRIMARY POWER SOURCE <br />SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS. [NEC 690.4(C), 705.8] <br />· LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND <br />SHALL BE A MINIMUM HEIGHT OF 3/8" IN WHITE ON A RED BACKGROUND. [NEC <br />690.31(G)(4)] <br />· IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN <br />ACCORDANCE WITH NEC 690.56(C). <br />· SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE <br />RETROFITTED ONTO THE EXISTING DWELLING AS PER THE 2019 CRC. THESE <br />SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH <br />BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON <br />MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM <br />AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. (CRC 314,315) <br />· SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC <br />SECTIONS 314 AND 315 TO BE VERIFIED AND INSPECTED BY THE INSPECTOR IN THE <br />FIELD. <br />· A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH Cal-OSHA <br />REGULATIONS, SECURED AND EXTENDING 3-FT ABOVE THE ROOF. <br />· ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL <br />EQUIPMENT PRIOR TO ANY INSPECTIONS. <br />PHOTOVOLTAIC MODULES AND PANEL SYSTEMS INSTALLED ON OR INTEGRAL <br />WITH BUILDINGS, OR TO BE FREESTANDING (NOT ATTACHED TO BUILDINGS) <br />SHALL BE TESTED, LISTED, AND IDENTIFIED WITH A FIRE CLASSIFICATION <br />(CLASS C MINIMUM) IN ACCORDANCE WITH UL1703. WHERE CLASS A OR B <br />ROOFING IS REQUIRED, THE PV SOLAR SYSTEM (PV PANEL & RACK) SHALL <br />HAVE THE SAME CLASS/TYPE RATING OR BETTER. <br />COUNTY ELECTRONIC STAMP <br />Bldg# 101119921 <br />Elec# 20183310 <br />The scope of the plans is for the installation of the solar <br />photovoltaic system only and the approval is subject to <br />compliance with all applicable city and state codes and <br />regulations regarding construction. The approval of the <br />plans does not constitute any certification of the accuracy, <br />completeness, or building permit status of the existing <br />buildings and structures as shown. <br />1210 E Avalon Ave Unit# <br />2- Solar7/11/2024