Laserfiche WebLink
ENGINEERING REPORT <br />* Distributed Dead Load 2.54psf <br />* Average Roof Point Dead Load 19.25 lbs <br />Plan review <br />TOTAL NUMBER OF MODULES 18 <br />TOTAL KW 7.02 KW <br />TOTAL AREA ~378 ft <br />Loads Used for Design <br />BUILDING CODE ASCE 7-16 <br />BASIC WIND SPEED 95.00 mph <br />GROUND SNOW LOAD 0.00 psf <br />SEISMIC (SS)1.462 <br />ELEVATION 65.00 ft <br />WIND EXPOSURE B <br />TOPOGRAPHICAL FACTOR KZT 1.00 <br />RISK CATEGORY II <br />VELOCITY PRESSURE, QZ 11.24 psf <br />2 <br />Inspection <br />PRODUCT NXT UMOUNT <br />MODULE MANUFACTURER JA Solar <br />MODEL 18 - JAM54S31 390/MR <br />MODULE WATTS 390 watts <br />MODULE LENGTH 67.79" <br />MODULE WIDTH 44.64" <br />MODULE THICKNESS 1.18" <br />MODULE WEIGHT 47.39 lbs <br />EXPANSION JOINTS Every 40' <br />RAILS DIRECTION EW <br />BUILDING HEIGHT 15.00 ft <br />SHORTEST BUILDING LENGTH 20.00 ft <br />ROOF TYPE Shingle <br />ATTACHMENT TYPE StrongHold Att Kit Comp <br />RAFTER SPACING 24.00" <br />* TOTAL WEIGHT 962.46 lbs <br />ROW SPACING 0.50" <br />COLUMN SPACING 0.50" <br />MID CLAMP NXT UMOUNT COMBO CLAMP <br />END CLAMP NXT UMOUNT COMBO CLAMP <br />* Calculated based on suggested quantity given on part list. <br />1113 S Shelley St <br />01/25/23